The effect and safety of the Tubridge flow diverting device are unknown in the treatment of intracranial aneurysms after optimization of the device, improvement in the deployment of the device, and accumulation of experience of using the device. This retrospective one-center study was performed to i...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Li, Shao, Qiu-Ji, Li, Tian-Xiao, Wang, Zi-Liang, Zhang, Kun, Gao, Bu-Lang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9771248/
https://www.ncbi.nlm.nih.gov/pubmed/36550831
http://dx.doi.org/10.1097/MD.0000000000031672
_version_ 1784854781372661760
author Li, Li
Shao, Qiu-Ji
Li, Tian-Xiao
Wang, Zi-Liang
Zhang, Kun
Gao, Bu-Lang
author_facet Li, Li
Shao, Qiu-Ji
Li, Tian-Xiao
Wang, Zi-Liang
Zhang, Kun
Gao, Bu-Lang
author_sort Li, Li
collection PubMed
description The effect and safety of the Tubridge flow diverting device are unknown in the treatment of intracranial aneurysms after optimization of the device, improvement in the deployment of the device, and accumulation of experience of using the device. This retrospective one-center study was performed to investigate the clinical effect and safety of the Tubridge flow diverting device in the treatment of unruptured intracranial aneurysms. Twenty-three patients with 33 unruptured intracranial aneurysms which were treated with the Tubridge device were retrospectively enrolled. The clinical data, endovascular procedure, complications, and follow-up were analyzed. Twenty-seven Tubridge devices were deployed to treat the 33 aneurysms, and the deployment was failed in 1 case, resulting in the success stenting rate of 96.3%. In 5 (15.2%) aneurysms, coils were loosely packed. Peri-procedural complications occurred in 2 patients (8.7%), including 1 procedure-related complication in which the distal end of a Tubridge device herniated into the aneurysm cavity. In another case, weakness of left upper limb occurred on the second day post procedure, with instent thrombosis being suspected, which was recovered after medication. No other complications occurred. Twenty-three (100%) patients had clinical follow-up 6 months later, with the mRS of 0 in 21 patients, 1 in 1, and 2 in 1. Five (21.7%) patients with 11 aneurysms underwent digital subtraction angiography at 6-month follow-up, with 8 aneurysms being completely occluded (Raymond grade I) and 3 aneurysms still visible (Raymond grade III). The Tubridge flow diverter may be safe and effective in the treatment of unruptured intracranial aneurysms with low perioperative complications and good follow-up outcomes even though multi-center and prospective clinical studies with a large size sample are still needed to validate these results.
format Online
Article
Text
id pubmed-9771248
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-97712482022-12-22 Effect and safety of Tubridge flow diverter in the treatment of unruptured intracranial aneurysms Li, Li Shao, Qiu-Ji Li, Tian-Xiao Wang, Zi-Liang Zhang, Kun Gao, Bu-Lang Medicine (Baltimore) 7100 The effect and safety of the Tubridge flow diverting device are unknown in the treatment of intracranial aneurysms after optimization of the device, improvement in the deployment of the device, and accumulation of experience of using the device. This retrospective one-center study was performed to investigate the clinical effect and safety of the Tubridge flow diverting device in the treatment of unruptured intracranial aneurysms. Twenty-three patients with 33 unruptured intracranial aneurysms which were treated with the Tubridge device were retrospectively enrolled. The clinical data, endovascular procedure, complications, and follow-up were analyzed. Twenty-seven Tubridge devices were deployed to treat the 33 aneurysms, and the deployment was failed in 1 case, resulting in the success stenting rate of 96.3%. In 5 (15.2%) aneurysms, coils were loosely packed. Peri-procedural complications occurred in 2 patients (8.7%), including 1 procedure-related complication in which the distal end of a Tubridge device herniated into the aneurysm cavity. In another case, weakness of left upper limb occurred on the second day post procedure, with instent thrombosis being suspected, which was recovered after medication. No other complications occurred. Twenty-three (100%) patients had clinical follow-up 6 months later, with the mRS of 0 in 21 patients, 1 in 1, and 2 in 1. Five (21.7%) patients with 11 aneurysms underwent digital subtraction angiography at 6-month follow-up, with 8 aneurysms being completely occluded (Raymond grade I) and 3 aneurysms still visible (Raymond grade III). The Tubridge flow diverter may be safe and effective in the treatment of unruptured intracranial aneurysms with low perioperative complications and good follow-up outcomes even though multi-center and prospective clinical studies with a large size sample are still needed to validate these results. Lippincott Williams & Wilkins 2022-12-16 /pmc/articles/PMC9771248/ /pubmed/36550831 http://dx.doi.org/10.1097/MD.0000000000031672 Text en Copyright © 2022 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC) (https://creativecommons.org/licenses/by-nc/4.0/) , where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal.
spellingShingle 7100
Li, Li
Shao, Qiu-Ji
Li, Tian-Xiao
Wang, Zi-Liang
Zhang, Kun
Gao, Bu-Lang
Effect and safety of Tubridge flow diverter in the treatment of unruptured intracranial aneurysms
title Effect and safety of Tubridge flow diverter in the treatment of unruptured intracranial aneurysms
title_full Effect and safety of Tubridge flow diverter in the treatment of unruptured intracranial aneurysms
title_fullStr Effect and safety of Tubridge flow diverter in the treatment of unruptured intracranial aneurysms
title_full_unstemmed Effect and safety of Tubridge flow diverter in the treatment of unruptured intracranial aneurysms
title_short Effect and safety of Tubridge flow diverter in the treatment of unruptured intracranial aneurysms
title_sort effect and safety of tubridge flow diverter in the treatment of unruptured intracranial aneurysms
topic 7100
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9771248/
https://www.ncbi.nlm.nih.gov/pubmed/36550831
http://dx.doi.org/10.1097/MD.0000000000031672
work_keys_str_mv AT lili effectandsafetyoftubridgeflowdiverterinthetreatmentofunrupturedintracranialaneurysms
AT shaoqiuji effectandsafetyoftubridgeflowdiverterinthetreatmentofunrupturedintracranialaneurysms
AT litianxiao effectandsafetyoftubridgeflowdiverterinthetreatmentofunrupturedintracranialaneurysms
AT wangziliang effectandsafetyoftubridgeflowdiverterinthetreatmentofunrupturedintracranialaneurysms
AT zhangkun effectandsafetyoftubridgeflowdiverterinthetreatmentofunrupturedintracranialaneurysms
AT gaobulang effectandsafetyoftubridgeflowdiverterinthetreatmentofunrupturedintracranialaneurysms