Cargando…

Examination of the microstructures of the lower cervical facet based on micro-computed tomography: A cadaver study

The cervical facet has complicated 3D microstructures and inhomogeneities. The cervical facet joint, which also participates in the formation, plays a certain role in regulating and limiting the movement of the spine. Correct identification and evaluation of its microstructure can help in the diagno...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Kun, Ji, Yucheng, Shi, Jun, Zhang, Shaojie, Song, Haoyu, Wang, Peng, Ma, Chunying, Zhang, Yansong, Dang, Yexing, Ma, Yuan, Wang, Xing, Li, Zhijun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9771288/
https://www.ncbi.nlm.nih.gov/pubmed/36550803
http://dx.doi.org/10.1097/MD.0000000000031805
_version_ 1784854791315259392
author Li, Kun
Ji, Yucheng
Shi, Jun
Zhang, Shaojie
Song, Haoyu
Wang, Peng
Ma, Chunying
Zhang, Yansong
Dang, Yexing
Ma, Yuan
Wang, Xing
Li, Zhijun
author_facet Li, Kun
Ji, Yucheng
Shi, Jun
Zhang, Shaojie
Song, Haoyu
Wang, Peng
Ma, Chunying
Zhang, Yansong
Dang, Yexing
Ma, Yuan
Wang, Xing
Li, Zhijun
author_sort Li, Kun
collection PubMed
description The cervical facet has complicated 3D microstructures and inhomogeneities. The cervical facet joint, which also participates in the formation, plays a certain role in regulating and limiting the movement of the spine. Correct identification and evaluation of its microstructure can help in the diagnosis of orthopedic disease and predict early phases of fracture risk. To evaluate the safety of the cervical spine by measuring and analyzing the microstructures and morphometric parameters of bone trabeculae in the normal cervical facet with high-resolution 3D micro-computed tomography. Thirty-one sets of C3 to C7 lower cervical vertebrae (155 vertebrae) were scanned using micro-computed tomography. The morphological characteristics and direction of trabecular bone in the facet of the lower cervical vertebrae were observed by selecting and rebuilding the areas of interest, and the changes in the microstructure of the areas of interest were calculated to reveal the structural characteristics and weak areas. Images indicated an ossified center between the superior and inferior articular processes of the lower cervical spine. The cellular bone trabeculae of the articular process had complex reticular microstructures. The trabecular bone plate near the cortical bone was lamellar and relatively dense, and it extended around and transformed into a network structure, and then into the rod-shaped trabecular bone. The rod-shaped trabeculae converged with the plate-shaped trabeculae with only 1 to 2 layers surrounding the trabeculae cavity. Statistical results of the morphological parameters of the trabecular bone showed that trabecular bone volume fraction values were significantly higher for C7 than for C3 to C6 (P < .05). There were significant differences between C7 and C3 to C5 and between C6 and C4 in bone surface area/bone volume (P < .05). There was a significant difference between C7 and C3 to C6 in trabecular bone thickness values (P < .05). The degree of anisotropy value was significantly smaller for C3 than for C6 and C7 (P < .05). The changes in the C3 to C7 microstructure were summarized in this study. The loading capacity and stress of the C7 articular process tended to be limited, and the risk of injury tended to be higher for the C7 articular process.
format Online
Article
Text
id pubmed-9771288
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-97712882022-12-22 Examination of the microstructures of the lower cervical facet based on micro-computed tomography: A cadaver study Li, Kun Ji, Yucheng Shi, Jun Zhang, Shaojie Song, Haoyu Wang, Peng Ma, Chunying Zhang, Yansong Dang, Yexing Ma, Yuan Wang, Xing Li, Zhijun Medicine (Baltimore) 3200 The cervical facet has complicated 3D microstructures and inhomogeneities. The cervical facet joint, which also participates in the formation, plays a certain role in regulating and limiting the movement of the spine. Correct identification and evaluation of its microstructure can help in the diagnosis of orthopedic disease and predict early phases of fracture risk. To evaluate the safety of the cervical spine by measuring and analyzing the microstructures and morphometric parameters of bone trabeculae in the normal cervical facet with high-resolution 3D micro-computed tomography. Thirty-one sets of C3 to C7 lower cervical vertebrae (155 vertebrae) were scanned using micro-computed tomography. The morphological characteristics and direction of trabecular bone in the facet of the lower cervical vertebrae were observed by selecting and rebuilding the areas of interest, and the changes in the microstructure of the areas of interest were calculated to reveal the structural characteristics and weak areas. Images indicated an ossified center between the superior and inferior articular processes of the lower cervical spine. The cellular bone trabeculae of the articular process had complex reticular microstructures. The trabecular bone plate near the cortical bone was lamellar and relatively dense, and it extended around and transformed into a network structure, and then into the rod-shaped trabecular bone. The rod-shaped trabeculae converged with the plate-shaped trabeculae with only 1 to 2 layers surrounding the trabeculae cavity. Statistical results of the morphological parameters of the trabecular bone showed that trabecular bone volume fraction values were significantly higher for C7 than for C3 to C6 (P < .05). There were significant differences between C7 and C3 to C5 and between C6 and C4 in bone surface area/bone volume (P < .05). There was a significant difference between C7 and C3 to C6 in trabecular bone thickness values (P < .05). The degree of anisotropy value was significantly smaller for C3 than for C6 and C7 (P < .05). The changes in the C3 to C7 microstructure were summarized in this study. The loading capacity and stress of the C7 articular process tended to be limited, and the risk of injury tended to be higher for the C7 articular process. Lippincott Williams & Wilkins 2022-12-16 /pmc/articles/PMC9771288/ /pubmed/36550803 http://dx.doi.org/10.1097/MD.0000000000031805 Text en Copyright © 2022 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC) (https://creativecommons.org/licenses/by-nc/4.0/) , where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal.
spellingShingle 3200
Li, Kun
Ji, Yucheng
Shi, Jun
Zhang, Shaojie
Song, Haoyu
Wang, Peng
Ma, Chunying
Zhang, Yansong
Dang, Yexing
Ma, Yuan
Wang, Xing
Li, Zhijun
Examination of the microstructures of the lower cervical facet based on micro-computed tomography: A cadaver study
title Examination of the microstructures of the lower cervical facet based on micro-computed tomography: A cadaver study
title_full Examination of the microstructures of the lower cervical facet based on micro-computed tomography: A cadaver study
title_fullStr Examination of the microstructures of the lower cervical facet based on micro-computed tomography: A cadaver study
title_full_unstemmed Examination of the microstructures of the lower cervical facet based on micro-computed tomography: A cadaver study
title_short Examination of the microstructures of the lower cervical facet based on micro-computed tomography: A cadaver study
title_sort examination of the microstructures of the lower cervical facet based on micro-computed tomography: a cadaver study
topic 3200
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9771288/
https://www.ncbi.nlm.nih.gov/pubmed/36550803
http://dx.doi.org/10.1097/MD.0000000000031805
work_keys_str_mv AT likun examinationofthemicrostructuresofthelowercervicalfacetbasedonmicrocomputedtomographyacadaverstudy
AT jiyucheng examinationofthemicrostructuresofthelowercervicalfacetbasedonmicrocomputedtomographyacadaverstudy
AT shijun examinationofthemicrostructuresofthelowercervicalfacetbasedonmicrocomputedtomographyacadaverstudy
AT zhangshaojie examinationofthemicrostructuresofthelowercervicalfacetbasedonmicrocomputedtomographyacadaverstudy
AT songhaoyu examinationofthemicrostructuresofthelowercervicalfacetbasedonmicrocomputedtomographyacadaverstudy
AT wangpeng examinationofthemicrostructuresofthelowercervicalfacetbasedonmicrocomputedtomographyacadaverstudy
AT machunying examinationofthemicrostructuresofthelowercervicalfacetbasedonmicrocomputedtomographyacadaverstudy
AT zhangyansong examinationofthemicrostructuresofthelowercervicalfacetbasedonmicrocomputedtomographyacadaverstudy
AT dangyexing examinationofthemicrostructuresofthelowercervicalfacetbasedonmicrocomputedtomographyacadaverstudy
AT mayuan examinationofthemicrostructuresofthelowercervicalfacetbasedonmicrocomputedtomographyacadaverstudy
AT wangxing examinationofthemicrostructuresofthelowercervicalfacetbasedonmicrocomputedtomographyacadaverstudy
AT lizhijun examinationofthemicrostructuresofthelowercervicalfacetbasedonmicrocomputedtomographyacadaverstudy