Cargando…

MRI comparative study of diffuse midline glioma, H3 K27-altered and glioma in the midline without H3 K27-altered

PURPOSE: The MRI features of Diffuse midline glioma, H3 K27-altered and glioma in the midline without H3 K27-altered were compared and analyzed, and the changes in the apparent diffusion coefficient (ADC) of the two groups were quantitatively analyzed. METHODS: The MRI images of 35 patients with Dif...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Ji-ping, Liu, Xue-jun, Lin, Hao-zhi, Cui, Chun-xiao, Yue, Ying-jie, Gao, Song, Xu, Hong-zhang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9773507/
https://www.ncbi.nlm.nih.gov/pubmed/36550486
http://dx.doi.org/10.1186/s12883-022-03026-0
_version_ 1784855206383583232
author Zhao, Ji-ping
Liu, Xue-jun
Lin, Hao-zhi
Cui, Chun-xiao
Yue, Ying-jie
Gao, Song
Xu, Hong-zhang
author_facet Zhao, Ji-ping
Liu, Xue-jun
Lin, Hao-zhi
Cui, Chun-xiao
Yue, Ying-jie
Gao, Song
Xu, Hong-zhang
author_sort Zhao, Ji-ping
collection PubMed
description PURPOSE: The MRI features of Diffuse midline glioma, H3 K27-altered and glioma in the midline without H3 K27-altered were compared and analyzed, and the changes in the apparent diffusion coefficient (ADC) of the two groups were quantitatively analyzed. METHODS: The MRI images of 35 patients with Diffuse midline gliomas, H3 K27-altered and gliomas in the midline without H3 K27-altered were analyzed retrospectively. The location, edge, signal, peritumoral edema and enhancement characteristics of the lesions were observed, and the changes in ADC values were analyzed. RESULTS: In the H3 K27-altered group, 85.7% (12/14) of the tumors were located in the thalamus and brainstem compared with 28.6% (6/21) in the no H3 K27-altered group. In the H3 K27-altered group, for tumors only located in the midline area, only 14.3% (1/7) had irregular shapes and unclear boundaries, while for tumors also invaded the extramidline tissues 85.7% (6/7) had irregular shapes and unclear boundaries.The"basilar artery wrapped sign” was found in 6 patients with tumors located in the pons in the H3 K27-altered group, but none in the no H3 K27-altered group had this sign. In the H3 K27-altered group, only 14.3% (1/7) of the tumors confined to the midline area had small cystic degeneration and necrosis, while for tumors also invaded the extramidline tissues, 100% (7/7) of the tumors had cystic degeneration and necrosis, and the cystic degeneration and necrosis only located in the extramidline region of the tumor in 6 cases.A total of 78.6% (11/14) of tumors in the H3 K27-altered group showed mild to moderate enhancement, while 47.6% (10/21) of tumors in the no H3 K27-altered group showed mild to moderate enhancement. The average peritumoral edema index was 1.13 in the H3 K27-altered group and 1.75 in the no H3 K27-altered group. The average ADC value of tumor in the H3 K27-altered group was 7.83 × 10(− 4) mm(2)/s, and the ratio to normal brain tissue was 0.844, while the values in the no H3 K27-altered group were 13.5 × 10(− 4) mm(2)/s and 1.75, respectively. CONCLUSION: Compared with gliomas in the midline without H3 K27-altered, The MRI findings and ADC value of Diffuse midline gliomas, H3K27-altered have some characteristics, which can help improve the diagnosis and differential diagnosis.
format Online
Article
Text
id pubmed-9773507
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-97735072022-12-23 MRI comparative study of diffuse midline glioma, H3 K27-altered and glioma in the midline without H3 K27-altered Zhao, Ji-ping Liu, Xue-jun Lin, Hao-zhi Cui, Chun-xiao Yue, Ying-jie Gao, Song Xu, Hong-zhang BMC Neurol Research PURPOSE: The MRI features of Diffuse midline glioma, H3 K27-altered and glioma in the midline without H3 K27-altered were compared and analyzed, and the changes in the apparent diffusion coefficient (ADC) of the two groups were quantitatively analyzed. METHODS: The MRI images of 35 patients with Diffuse midline gliomas, H3 K27-altered and gliomas in the midline without H3 K27-altered were analyzed retrospectively. The location, edge, signal, peritumoral edema and enhancement characteristics of the lesions were observed, and the changes in ADC values were analyzed. RESULTS: In the H3 K27-altered group, 85.7% (12/14) of the tumors were located in the thalamus and brainstem compared with 28.6% (6/21) in the no H3 K27-altered group. In the H3 K27-altered group, for tumors only located in the midline area, only 14.3% (1/7) had irregular shapes and unclear boundaries, while for tumors also invaded the extramidline tissues 85.7% (6/7) had irregular shapes and unclear boundaries.The"basilar artery wrapped sign” was found in 6 patients with tumors located in the pons in the H3 K27-altered group, but none in the no H3 K27-altered group had this sign. In the H3 K27-altered group, only 14.3% (1/7) of the tumors confined to the midline area had small cystic degeneration and necrosis, while for tumors also invaded the extramidline tissues, 100% (7/7) of the tumors had cystic degeneration and necrosis, and the cystic degeneration and necrosis only located in the extramidline region of the tumor in 6 cases.A total of 78.6% (11/14) of tumors in the H3 K27-altered group showed mild to moderate enhancement, while 47.6% (10/21) of tumors in the no H3 K27-altered group showed mild to moderate enhancement. The average peritumoral edema index was 1.13 in the H3 K27-altered group and 1.75 in the no H3 K27-altered group. The average ADC value of tumor in the H3 K27-altered group was 7.83 × 10(− 4) mm(2)/s, and the ratio to normal brain tissue was 0.844, while the values in the no H3 K27-altered group were 13.5 × 10(− 4) mm(2)/s and 1.75, respectively. CONCLUSION: Compared with gliomas in the midline without H3 K27-altered, The MRI findings and ADC value of Diffuse midline gliomas, H3K27-altered have some characteristics, which can help improve the diagnosis and differential diagnosis. BioMed Central 2022-12-22 /pmc/articles/PMC9773507/ /pubmed/36550486 http://dx.doi.org/10.1186/s12883-022-03026-0 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Zhao, Ji-ping
Liu, Xue-jun
Lin, Hao-zhi
Cui, Chun-xiao
Yue, Ying-jie
Gao, Song
Xu, Hong-zhang
MRI comparative study of diffuse midline glioma, H3 K27-altered and glioma in the midline without H3 K27-altered
title MRI comparative study of diffuse midline glioma, H3 K27-altered and glioma in the midline without H3 K27-altered
title_full MRI comparative study of diffuse midline glioma, H3 K27-altered and glioma in the midline without H3 K27-altered
title_fullStr MRI comparative study of diffuse midline glioma, H3 K27-altered and glioma in the midline without H3 K27-altered
title_full_unstemmed MRI comparative study of diffuse midline glioma, H3 K27-altered and glioma in the midline without H3 K27-altered
title_short MRI comparative study of diffuse midline glioma, H3 K27-altered and glioma in the midline without H3 K27-altered
title_sort mri comparative study of diffuse midline glioma, h3 k27-altered and glioma in the midline without h3 k27-altered
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9773507/
https://www.ncbi.nlm.nih.gov/pubmed/36550486
http://dx.doi.org/10.1186/s12883-022-03026-0
work_keys_str_mv AT zhaojiping mricomparativestudyofdiffusemidlinegliomah3k27alteredandgliomainthemidlinewithouth3k27altered
AT liuxuejun mricomparativestudyofdiffusemidlinegliomah3k27alteredandgliomainthemidlinewithouth3k27altered
AT linhaozhi mricomparativestudyofdiffusemidlinegliomah3k27alteredandgliomainthemidlinewithouth3k27altered
AT cuichunxiao mricomparativestudyofdiffusemidlinegliomah3k27alteredandgliomainthemidlinewithouth3k27altered
AT yueyingjie mricomparativestudyofdiffusemidlinegliomah3k27alteredandgliomainthemidlinewithouth3k27altered
AT gaosong mricomparativestudyofdiffusemidlinegliomah3k27alteredandgliomainthemidlinewithouth3k27altered
AT xuhongzhang mricomparativestudyofdiffusemidlinegliomah3k27alteredandgliomainthemidlinewithouth3k27altered