Cargando…

A Cost-Effective Reusable Tissue Mimicking Phantom for High Intensity Focused Ultrasonic Liver Surgery

A polyacrylamide polysaccharide hydrogel (PASG) containing a nonionic surfactant of the polyoxyethylene nonylphenyl ethers series (NP14) has been adapted to the fabrication of a reusable cost-effective ultrasonic tissue-mimicking phantom for real-time visualization of the thermal lesions by high int...

Descripción completa

Detalles Bibliográficos
Autores principales: Guntur, Sitaramanjaneya Reddy, Kim, Seong-Chan, Choi, Min-Joo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9774244/
https://www.ncbi.nlm.nih.gov/pubmed/36550992
http://dx.doi.org/10.3390/bioengineering9120786
_version_ 1784855360295665664
author Guntur, Sitaramanjaneya Reddy
Kim, Seong-Chan
Choi, Min-Joo
author_facet Guntur, Sitaramanjaneya Reddy
Kim, Seong-Chan
Choi, Min-Joo
author_sort Guntur, Sitaramanjaneya Reddy
collection PubMed
description A polyacrylamide polysaccharide hydrogel (PASG) containing a nonionic surfactant of the polyoxyethylene nonylphenyl ethers series (NP14) has been adapted to the fabrication of a reusable cost-effective ultrasonic tissue-mimicking phantom for real-time visualization of the thermal lesions by high intensity focused ultrasound (HIFU) irradiation. The constructed NP14 (40% in w/v) PASG is optically transparent at room temperatures, and it turns out to be opaque white as heated over the clouding points of about 55 °C and returns to its original transparent state after cooling. The acoustic property of the proposed phantom is similar to those of human liver tissues, which includes the acoustic impedance of 1.68 Mrayls, the speed of sound of 1595 ± 5 m/s, the attenuation coefficient of 0.52 ± 0.05 dB cm(−1) (at 1 MHz), the backscatter coefficient of 0.21 ± 0.09 × 10(−3) sr(−1) cm(−1) (at 1 MHz), and the nonlinear parameter B/A of 6.4 ± 0.2. The NP14-PASG was tested to assess the characteristic information (sizes, shapes, and locations) of the thermal lesions visualized when exposed to typical HIFU fields (1.1 MHz, focal pressure up to 20.1 MPa, focal intensity 4075 W/cm(2)). The proposed NP14-PASG is expected to replace the existing costly BSA-PASG used for more effective testing of the performance of therapeutic ultrasonic devices based on thermal mechanisms.
format Online
Article
Text
id pubmed-9774244
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97742442022-12-23 A Cost-Effective Reusable Tissue Mimicking Phantom for High Intensity Focused Ultrasonic Liver Surgery Guntur, Sitaramanjaneya Reddy Kim, Seong-Chan Choi, Min-Joo Bioengineering (Basel) Article A polyacrylamide polysaccharide hydrogel (PASG) containing a nonionic surfactant of the polyoxyethylene nonylphenyl ethers series (NP14) has been adapted to the fabrication of a reusable cost-effective ultrasonic tissue-mimicking phantom for real-time visualization of the thermal lesions by high intensity focused ultrasound (HIFU) irradiation. The constructed NP14 (40% in w/v) PASG is optically transparent at room temperatures, and it turns out to be opaque white as heated over the clouding points of about 55 °C and returns to its original transparent state after cooling. The acoustic property of the proposed phantom is similar to those of human liver tissues, which includes the acoustic impedance of 1.68 Mrayls, the speed of sound of 1595 ± 5 m/s, the attenuation coefficient of 0.52 ± 0.05 dB cm(−1) (at 1 MHz), the backscatter coefficient of 0.21 ± 0.09 × 10(−3) sr(−1) cm(−1) (at 1 MHz), and the nonlinear parameter B/A of 6.4 ± 0.2. The NP14-PASG was tested to assess the characteristic information (sizes, shapes, and locations) of the thermal lesions visualized when exposed to typical HIFU fields (1.1 MHz, focal pressure up to 20.1 MPa, focal intensity 4075 W/cm(2)). The proposed NP14-PASG is expected to replace the existing costly BSA-PASG used for more effective testing of the performance of therapeutic ultrasonic devices based on thermal mechanisms. MDPI 2022-12-09 /pmc/articles/PMC9774244/ /pubmed/36550992 http://dx.doi.org/10.3390/bioengineering9120786 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Guntur, Sitaramanjaneya Reddy
Kim, Seong-Chan
Choi, Min-Joo
A Cost-Effective Reusable Tissue Mimicking Phantom for High Intensity Focused Ultrasonic Liver Surgery
title A Cost-Effective Reusable Tissue Mimicking Phantom for High Intensity Focused Ultrasonic Liver Surgery
title_full A Cost-Effective Reusable Tissue Mimicking Phantom for High Intensity Focused Ultrasonic Liver Surgery
title_fullStr A Cost-Effective Reusable Tissue Mimicking Phantom for High Intensity Focused Ultrasonic Liver Surgery
title_full_unstemmed A Cost-Effective Reusable Tissue Mimicking Phantom for High Intensity Focused Ultrasonic Liver Surgery
title_short A Cost-Effective Reusable Tissue Mimicking Phantom for High Intensity Focused Ultrasonic Liver Surgery
title_sort cost-effective reusable tissue mimicking phantom for high intensity focused ultrasonic liver surgery
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9774244/
https://www.ncbi.nlm.nih.gov/pubmed/36550992
http://dx.doi.org/10.3390/bioengineering9120786
work_keys_str_mv AT guntursitaramanjaneyareddy acosteffectivereusabletissuemimickingphantomforhighintensityfocusedultrasonicliversurgery
AT kimseongchan acosteffectivereusabletissuemimickingphantomforhighintensityfocusedultrasonicliversurgery
AT choiminjoo acosteffectivereusabletissuemimickingphantomforhighintensityfocusedultrasonicliversurgery
AT guntursitaramanjaneyareddy costeffectivereusabletissuemimickingphantomforhighintensityfocusedultrasonicliversurgery
AT kimseongchan costeffectivereusabletissuemimickingphantomforhighintensityfocusedultrasonicliversurgery
AT choiminjoo costeffectivereusabletissuemimickingphantomforhighintensityfocusedultrasonicliversurgery