Cargando…

One-Step Photochemical Immobilization of Aptamer on Graphene for Label-Free Detection of NT-proBNP

A novel photochemical technological route for one-step functionalization of a graphene surface with an azide-modified DNA aptamer for biomarkers is developed. The methodology is demonstrated for the functionalization of a DNA aptamer for an N-terminal B-type natriuretic peptide (NT-proBNP) heart fai...

Descripción completa

Detalles Bibliográficos
Autores principales: Nekrasov, Nikita, Kudriavtseva, Anastasiia, Orlov, Alexey V., Gadjanski, Ivana, Nikitin, Petr I., Bobrinetskiy, Ivan, Knežević, Nikola Ž.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9775241/
https://www.ncbi.nlm.nih.gov/pubmed/36551038
http://dx.doi.org/10.3390/bios12121071
_version_ 1784855595752357888
author Nekrasov, Nikita
Kudriavtseva, Anastasiia
Orlov, Alexey V.
Gadjanski, Ivana
Nikitin, Petr I.
Bobrinetskiy, Ivan
Knežević, Nikola Ž.
author_facet Nekrasov, Nikita
Kudriavtseva, Anastasiia
Orlov, Alexey V.
Gadjanski, Ivana
Nikitin, Petr I.
Bobrinetskiy, Ivan
Knežević, Nikola Ž.
author_sort Nekrasov, Nikita
collection PubMed
description A novel photochemical technological route for one-step functionalization of a graphene surface with an azide-modified DNA aptamer for biomarkers is developed. The methodology is demonstrated for the functionalization of a DNA aptamer for an N-terminal B-type natriuretic peptide (NT-proBNP) heart failure biomarker on the surface of a graphene channel within a system based on a liquid-gated graphene field effect transistor (GFET). The limit of detection (LOD) of the aptamer-functionalized sensor is 0.01 pg/mL with short response time (75 s) for clinically relevant concentrations of the cardiac biomarker, which could be of relevance for point-of-care (POC) applications. The novel methodology could be applicable for the development of different graphene-based biosensors for fast, stable, real-time, and highly sensitive detection of disease markers.
format Online
Article
Text
id pubmed-9775241
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97752412022-12-23 One-Step Photochemical Immobilization of Aptamer on Graphene for Label-Free Detection of NT-proBNP Nekrasov, Nikita Kudriavtseva, Anastasiia Orlov, Alexey V. Gadjanski, Ivana Nikitin, Petr I. Bobrinetskiy, Ivan Knežević, Nikola Ž. Biosensors (Basel) Article A novel photochemical technological route for one-step functionalization of a graphene surface with an azide-modified DNA aptamer for biomarkers is developed. The methodology is demonstrated for the functionalization of a DNA aptamer for an N-terminal B-type natriuretic peptide (NT-proBNP) heart failure biomarker on the surface of a graphene channel within a system based on a liquid-gated graphene field effect transistor (GFET). The limit of detection (LOD) of the aptamer-functionalized sensor is 0.01 pg/mL with short response time (75 s) for clinically relevant concentrations of the cardiac biomarker, which could be of relevance for point-of-care (POC) applications. The novel methodology could be applicable for the development of different graphene-based biosensors for fast, stable, real-time, and highly sensitive detection of disease markers. MDPI 2022-11-23 /pmc/articles/PMC9775241/ /pubmed/36551038 http://dx.doi.org/10.3390/bios12121071 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Nekrasov, Nikita
Kudriavtseva, Anastasiia
Orlov, Alexey V.
Gadjanski, Ivana
Nikitin, Petr I.
Bobrinetskiy, Ivan
Knežević, Nikola Ž.
One-Step Photochemical Immobilization of Aptamer on Graphene for Label-Free Detection of NT-proBNP
title One-Step Photochemical Immobilization of Aptamer on Graphene for Label-Free Detection of NT-proBNP
title_full One-Step Photochemical Immobilization of Aptamer on Graphene for Label-Free Detection of NT-proBNP
title_fullStr One-Step Photochemical Immobilization of Aptamer on Graphene for Label-Free Detection of NT-proBNP
title_full_unstemmed One-Step Photochemical Immobilization of Aptamer on Graphene for Label-Free Detection of NT-proBNP
title_short One-Step Photochemical Immobilization of Aptamer on Graphene for Label-Free Detection of NT-proBNP
title_sort one-step photochemical immobilization of aptamer on graphene for label-free detection of nt-probnp
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9775241/
https://www.ncbi.nlm.nih.gov/pubmed/36551038
http://dx.doi.org/10.3390/bios12121071
work_keys_str_mv AT nekrasovnikita onestepphotochemicalimmobilizationofaptamerongrapheneforlabelfreedetectionofntprobnp
AT kudriavtsevaanastasiia onestepphotochemicalimmobilizationofaptamerongrapheneforlabelfreedetectionofntprobnp
AT orlovalexeyv onestepphotochemicalimmobilizationofaptamerongrapheneforlabelfreedetectionofntprobnp
AT gadjanskiivana onestepphotochemicalimmobilizationofaptamerongrapheneforlabelfreedetectionofntprobnp
AT nikitinpetri onestepphotochemicalimmobilizationofaptamerongrapheneforlabelfreedetectionofntprobnp
AT bobrinetskiyivan onestepphotochemicalimmobilizationofaptamerongrapheneforlabelfreedetectionofntprobnp
AT knezevicnikolaz onestepphotochemicalimmobilizationofaptamerongrapheneforlabelfreedetectionofntprobnp