Cargando…

Fabrication of a Molecularly Imprinted Nano-Interface-Based Electrochemical Biosensor for the Detection of CagA Virulence Factors of H. pylori

H. pylori is responsible for several stomach-related diseases including gastric cancer. The main virulence factor responsible for its establishment in human gastric cells is known as CagA. Therefore, in this study, we have fabricated a highly sensitive MIP-based electrochemical biosensor for the det...

Descripción completa

Detalles Bibliográficos
Autores principales: Saxena, Kirti, Murti, Bayu Tri, Yang, Po-Kang, Malhotra, Bansi Dhar, Chauhan, Nidhi, Jain, Utkarsh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9775653/
https://www.ncbi.nlm.nih.gov/pubmed/36551033
http://dx.doi.org/10.3390/bios12121066
_version_ 1784855697285971968
author Saxena, Kirti
Murti, Bayu Tri
Yang, Po-Kang
Malhotra, Bansi Dhar
Chauhan, Nidhi
Jain, Utkarsh
author_facet Saxena, Kirti
Murti, Bayu Tri
Yang, Po-Kang
Malhotra, Bansi Dhar
Chauhan, Nidhi
Jain, Utkarsh
author_sort Saxena, Kirti
collection PubMed
description H. pylori is responsible for several stomach-related diseases including gastric cancer. The main virulence factor responsible for its establishment in human gastric cells is known as CagA. Therefore, in this study, we have fabricated a highly sensitive MIP-based electrochemical biosensor for the detection of CagA. For this, an rGO and gold-coated, screen-printed electrode sensing platform was designed to provide a surface for the immobilization of a CagA-specific, molecularly imprinted polymer; then it was characterized electrochemically. Interestingly, molecular dynamics simulations were studied to optimize the MIP prepolymerization system, resulting in a well-matched, optimized molar ratio within the experiment. A low binding energy upon template removal indicates the capability of MIP to recognize the CagA antigen through a strong binding affinity. Under the optimized electrochemical experimental conditions, the fabricated CagA-MIP/Au/rGO@SPE sensor exhibited high sensitivity (0.275 µA ng(−1) mL(−1)) and a very low limit of detection (0.05 ng mL(−1)) in a linear range of 0.05–50 ng mL(−1). The influence of other possible interferents in analytical response has also been observed with the successful determination of the CagA antigen.
format Online
Article
Text
id pubmed-9775653
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97756532022-12-23 Fabrication of a Molecularly Imprinted Nano-Interface-Based Electrochemical Biosensor for the Detection of CagA Virulence Factors of H. pylori Saxena, Kirti Murti, Bayu Tri Yang, Po-Kang Malhotra, Bansi Dhar Chauhan, Nidhi Jain, Utkarsh Biosensors (Basel) Article H. pylori is responsible for several stomach-related diseases including gastric cancer. The main virulence factor responsible for its establishment in human gastric cells is known as CagA. Therefore, in this study, we have fabricated a highly sensitive MIP-based electrochemical biosensor for the detection of CagA. For this, an rGO and gold-coated, screen-printed electrode sensing platform was designed to provide a surface for the immobilization of a CagA-specific, molecularly imprinted polymer; then it was characterized electrochemically. Interestingly, molecular dynamics simulations were studied to optimize the MIP prepolymerization system, resulting in a well-matched, optimized molar ratio within the experiment. A low binding energy upon template removal indicates the capability of MIP to recognize the CagA antigen through a strong binding affinity. Under the optimized electrochemical experimental conditions, the fabricated CagA-MIP/Au/rGO@SPE sensor exhibited high sensitivity (0.275 µA ng(−1) mL(−1)) and a very low limit of detection (0.05 ng mL(−1)) in a linear range of 0.05–50 ng mL(−1). The influence of other possible interferents in analytical response has also been observed with the successful determination of the CagA antigen. MDPI 2022-11-23 /pmc/articles/PMC9775653/ /pubmed/36551033 http://dx.doi.org/10.3390/bios12121066 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Saxena, Kirti
Murti, Bayu Tri
Yang, Po-Kang
Malhotra, Bansi Dhar
Chauhan, Nidhi
Jain, Utkarsh
Fabrication of a Molecularly Imprinted Nano-Interface-Based Electrochemical Biosensor for the Detection of CagA Virulence Factors of H. pylori
title Fabrication of a Molecularly Imprinted Nano-Interface-Based Electrochemical Biosensor for the Detection of CagA Virulence Factors of H. pylori
title_full Fabrication of a Molecularly Imprinted Nano-Interface-Based Electrochemical Biosensor for the Detection of CagA Virulence Factors of H. pylori
title_fullStr Fabrication of a Molecularly Imprinted Nano-Interface-Based Electrochemical Biosensor for the Detection of CagA Virulence Factors of H. pylori
title_full_unstemmed Fabrication of a Molecularly Imprinted Nano-Interface-Based Electrochemical Biosensor for the Detection of CagA Virulence Factors of H. pylori
title_short Fabrication of a Molecularly Imprinted Nano-Interface-Based Electrochemical Biosensor for the Detection of CagA Virulence Factors of H. pylori
title_sort fabrication of a molecularly imprinted nano-interface-based electrochemical biosensor for the detection of caga virulence factors of h. pylori
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9775653/
https://www.ncbi.nlm.nih.gov/pubmed/36551033
http://dx.doi.org/10.3390/bios12121066
work_keys_str_mv AT saxenakirti fabricationofamolecularlyimprintednanointerfacebasedelectrochemicalbiosensorforthedetectionofcagavirulencefactorsofhpylori
AT murtibayutri fabricationofamolecularlyimprintednanointerfacebasedelectrochemicalbiosensorforthedetectionofcagavirulencefactorsofhpylori
AT yangpokang fabricationofamolecularlyimprintednanointerfacebasedelectrochemicalbiosensorforthedetectionofcagavirulencefactorsofhpylori
AT malhotrabansidhar fabricationofamolecularlyimprintednanointerfacebasedelectrochemicalbiosensorforthedetectionofcagavirulencefactorsofhpylori
AT chauhannidhi fabricationofamolecularlyimprintednanointerfacebasedelectrochemicalbiosensorforthedetectionofcagavirulencefactorsofhpylori
AT jainutkarsh fabricationofamolecularlyimprintednanointerfacebasedelectrochemicalbiosensorforthedetectionofcagavirulencefactorsofhpylori