Cargando…

Determination of the Assigned Values of Blood Cells by an Impedance Method for Hematological Reference Samples Used in Hematology External Quality Assessment (EQA) Programs

The research into and production of hematological reference samples used to implement an external quality assessment (EQA) to check the quality of hematology tests are necessary for hematology laboratories in Vietnam. In this research, the study team determined the assessment values of blood cell co...

Descripción completa

Detalles Bibliográficos
Autores principales: Vo, Ngoc Nguyen, Tran, Huu Tam, Nguyen, Thi Hong Phuong, Vu, Dinh Dung, Vo, Thanh Sang, Nguyen, Thuy Huong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9775971/
https://www.ncbi.nlm.nih.gov/pubmed/36551923
http://dx.doi.org/10.3390/biomedicines10123169
Descripción
Sumario:The research into and production of hematological reference samples used to implement an external quality assessment (EQA) to check the quality of hematology tests are necessary for hematology laboratories in Vietnam. In this research, the study team determined the assessment values of blood cell count (human RBCs, pseudo-leucocytes, and pseudo-platelets) by the impedance method used in hematology EQA programs. The hematological reference samples were controlled at three concentration levels: low, normal, and high. Determination of the assigned value (mean ± 2SD) was performed for the following hematology analyzer series by impedance method: ABX Micros 60, Celldyn 1700, and Mindray BC 2000. Each device was sent to 10 different laboratories for evaluation. Research results for assigned values of each model (ABX Micros 60, Celldyn 1700, and Mindray BC 2000) were determined at the three concentrations. For the ABX Micros 60 and Celldyn 1700 series, 80% of laboratories had analytical results within assigned values. For the Mindray BC 2000 series, 100% of laboratories had analytical results within assigned values. The measurement results for the number of human RBCs, pseudo-leucocytes, and pseudo-platelets on each analyzer were similar between the 10 laboratories; the results of the three hematology analyzer series using the impedance method were different and the difference was statistically significant (p < 0.05). Thus, hematological reference samples for measuring the number of blood cells meeting the standards so that they can evaluate the results of laboratories using the impedance method: ABX, Celldyn 1700, Mindray BC 2000.