Cargando…

Effect of Coupling Medium on Penetration Depth in Microwave Medical Imaging

In microwave medical imaging, the human skin reflects most of microwave energy due to the impedance mismatch between the air and the body. As a result, only a small portion of the microwave energy can enter the body and work for medical purpose. One solution to tackle this issue is to use a coupling...

Descripción completa

Detalles Bibliográficos
Autores principales: Shao, Wenyi, Zhou, Beibei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9776435/
https://www.ncbi.nlm.nih.gov/pubmed/36552911
http://dx.doi.org/10.3390/diagnostics12122906
_version_ 1784855864816959488
author Shao, Wenyi
Zhou, Beibei
author_facet Shao, Wenyi
Zhou, Beibei
author_sort Shao, Wenyi
collection PubMed
description In microwave medical imaging, the human skin reflects most of microwave energy due to the impedance mismatch between the air and the body. As a result, only a small portion of the microwave energy can enter the body and work for medical purpose. One solution to tackle this issue is to use a coupling (or matching) medium, which can reduce unwanted reflections on the skin and meanwhile improve spatial imaging resolution. A few types of fluids were measured in this paper for their dielectric properties between 500 MHz and 13.5 GHz. Measurements were performed by a Keysight programmable network analyzer (PNA) with a dielectric probe kit, and dielectric constant and conductivity of the fluids were presented in this paper. Then, quantitative computations were exercised to present the attenuations due to the reflection on the skin and to the loss in each coupling medium, based on the measured liquid dielectric values. Finally, electromagnetic simulations verified that the coupling liquid can allow more microwave energy to enter the body to allow for a more efficient medical examination.
format Online
Article
Text
id pubmed-9776435
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97764352022-12-23 Effect of Coupling Medium on Penetration Depth in Microwave Medical Imaging Shao, Wenyi Zhou, Beibei Diagnostics (Basel) Article In microwave medical imaging, the human skin reflects most of microwave energy due to the impedance mismatch between the air and the body. As a result, only a small portion of the microwave energy can enter the body and work for medical purpose. One solution to tackle this issue is to use a coupling (or matching) medium, which can reduce unwanted reflections on the skin and meanwhile improve spatial imaging resolution. A few types of fluids were measured in this paper for their dielectric properties between 500 MHz and 13.5 GHz. Measurements were performed by a Keysight programmable network analyzer (PNA) with a dielectric probe kit, and dielectric constant and conductivity of the fluids were presented in this paper. Then, quantitative computations were exercised to present the attenuations due to the reflection on the skin and to the loss in each coupling medium, based on the measured liquid dielectric values. Finally, electromagnetic simulations verified that the coupling liquid can allow more microwave energy to enter the body to allow for a more efficient medical examination. MDPI 2022-11-22 /pmc/articles/PMC9776435/ /pubmed/36552911 http://dx.doi.org/10.3390/diagnostics12122906 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shao, Wenyi
Zhou, Beibei
Effect of Coupling Medium on Penetration Depth in Microwave Medical Imaging
title Effect of Coupling Medium on Penetration Depth in Microwave Medical Imaging
title_full Effect of Coupling Medium on Penetration Depth in Microwave Medical Imaging
title_fullStr Effect of Coupling Medium on Penetration Depth in Microwave Medical Imaging
title_full_unstemmed Effect of Coupling Medium on Penetration Depth in Microwave Medical Imaging
title_short Effect of Coupling Medium on Penetration Depth in Microwave Medical Imaging
title_sort effect of coupling medium on penetration depth in microwave medical imaging
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9776435/
https://www.ncbi.nlm.nih.gov/pubmed/36552911
http://dx.doi.org/10.3390/diagnostics12122906
work_keys_str_mv AT shaowenyi effectofcouplingmediumonpenetrationdepthinmicrowavemedicalimaging
AT zhoubeibei effectofcouplingmediumonpenetrationdepthinmicrowavemedicalimaging