Cargando…
Effect of Coupling Medium on Penetration Depth in Microwave Medical Imaging
In microwave medical imaging, the human skin reflects most of microwave energy due to the impedance mismatch between the air and the body. As a result, only a small portion of the microwave energy can enter the body and work for medical purpose. One solution to tackle this issue is to use a coupling...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9776435/ https://www.ncbi.nlm.nih.gov/pubmed/36552911 http://dx.doi.org/10.3390/diagnostics12122906 |
_version_ | 1784855864816959488 |
---|---|
author | Shao, Wenyi Zhou, Beibei |
author_facet | Shao, Wenyi Zhou, Beibei |
author_sort | Shao, Wenyi |
collection | PubMed |
description | In microwave medical imaging, the human skin reflects most of microwave energy due to the impedance mismatch between the air and the body. As a result, only a small portion of the microwave energy can enter the body and work for medical purpose. One solution to tackle this issue is to use a coupling (or matching) medium, which can reduce unwanted reflections on the skin and meanwhile improve spatial imaging resolution. A few types of fluids were measured in this paper for their dielectric properties between 500 MHz and 13.5 GHz. Measurements were performed by a Keysight programmable network analyzer (PNA) with a dielectric probe kit, and dielectric constant and conductivity of the fluids were presented in this paper. Then, quantitative computations were exercised to present the attenuations due to the reflection on the skin and to the loss in each coupling medium, based on the measured liquid dielectric values. Finally, electromagnetic simulations verified that the coupling liquid can allow more microwave energy to enter the body to allow for a more efficient medical examination. |
format | Online Article Text |
id | pubmed-9776435 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-97764352022-12-23 Effect of Coupling Medium on Penetration Depth in Microwave Medical Imaging Shao, Wenyi Zhou, Beibei Diagnostics (Basel) Article In microwave medical imaging, the human skin reflects most of microwave energy due to the impedance mismatch between the air and the body. As a result, only a small portion of the microwave energy can enter the body and work for medical purpose. One solution to tackle this issue is to use a coupling (or matching) medium, which can reduce unwanted reflections on the skin and meanwhile improve spatial imaging resolution. A few types of fluids were measured in this paper for their dielectric properties between 500 MHz and 13.5 GHz. Measurements were performed by a Keysight programmable network analyzer (PNA) with a dielectric probe kit, and dielectric constant and conductivity of the fluids were presented in this paper. Then, quantitative computations were exercised to present the attenuations due to the reflection on the skin and to the loss in each coupling medium, based on the measured liquid dielectric values. Finally, electromagnetic simulations verified that the coupling liquid can allow more microwave energy to enter the body to allow for a more efficient medical examination. MDPI 2022-11-22 /pmc/articles/PMC9776435/ /pubmed/36552911 http://dx.doi.org/10.3390/diagnostics12122906 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Shao, Wenyi Zhou, Beibei Effect of Coupling Medium on Penetration Depth in Microwave Medical Imaging |
title | Effect of Coupling Medium on Penetration Depth in Microwave Medical Imaging |
title_full | Effect of Coupling Medium on Penetration Depth in Microwave Medical Imaging |
title_fullStr | Effect of Coupling Medium on Penetration Depth in Microwave Medical Imaging |
title_full_unstemmed | Effect of Coupling Medium on Penetration Depth in Microwave Medical Imaging |
title_short | Effect of Coupling Medium on Penetration Depth in Microwave Medical Imaging |
title_sort | effect of coupling medium on penetration depth in microwave medical imaging |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9776435/ https://www.ncbi.nlm.nih.gov/pubmed/36552911 http://dx.doi.org/10.3390/diagnostics12122906 |
work_keys_str_mv | AT shaowenyi effectofcouplingmediumonpenetrationdepthinmicrowavemedicalimaging AT zhoubeibei effectofcouplingmediumonpenetrationdepthinmicrowavemedicalimaging |