Intraoperative Assessment of High-Risk Thyroid Nodules Based on Electrical Impedance Measurements: A Feasibility Study

Precise diagnosis of thyroid nodules is challenging due to non-diagnostic/inconclusive results and uncertainties about the malignancy of follicular neoplasms (FNs), even in frozen-section pathology. Therefore, surgical management, especially in Bethesda III and IV categories, may be complicated, and...

Descripción completa

Detalles Bibliográficos
Autores principales: Beheshti Firoozabadi, Jalil, Mahdavi, Reihane, Shamsi, Khosro, Ataee, Hossein, Shafiee, Abdollah, Ebrahiminik, Hojat, Chegini, Hossein, Hoseinpour, Parisa, Moradi, Afshin, Yousefpour, Narges, Aghaei, Faeze, Fardoost, Ali, Ghelichli, Alireza, Mokhtari Dowlatabad, Hadi, Hajighasemi, Farzane, Sami, Nafiseh, Rouhollah Miri, Seyed, Akbari, Mohammad Esmaeil, Abdolahad, Mohammad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9776834/
https://www.ncbi.nlm.nih.gov/pubmed/36552958
http://dx.doi.org/10.3390/diagnostics12122950
_version_ 1784855956379664384
author Beheshti Firoozabadi, Jalil
Mahdavi, Reihane
Shamsi, Khosro
Ataee, Hossein
Shafiee, Abdollah
Ebrahiminik, Hojat
Chegini, Hossein
Hoseinpour, Parisa
Moradi, Afshin
Yousefpour, Narges
Aghaei, Faeze
Fardoost, Ali
Ghelichli, Alireza
Mokhtari Dowlatabad, Hadi
Hajighasemi, Farzane
Sami, Nafiseh
Rouhollah Miri, Seyed
Akbari, Mohammad Esmaeil
Abdolahad, Mohammad
author_facet Beheshti Firoozabadi, Jalil
Mahdavi, Reihane
Shamsi, Khosro
Ataee, Hossein
Shafiee, Abdollah
Ebrahiminik, Hojat
Chegini, Hossein
Hoseinpour, Parisa
Moradi, Afshin
Yousefpour, Narges
Aghaei, Faeze
Fardoost, Ali
Ghelichli, Alireza
Mokhtari Dowlatabad, Hadi
Hajighasemi, Farzane
Sami, Nafiseh
Rouhollah Miri, Seyed
Akbari, Mohammad Esmaeil
Abdolahad, Mohammad
author_sort Beheshti Firoozabadi, Jalil
collection PubMed
description Precise diagnosis of thyroid nodules is challenging due to non-diagnostic/inconclusive results and uncertainties about the malignancy of follicular neoplasms (FNs), even in frozen-section pathology. Therefore, surgical management, especially in Bethesda III and IV categories, may be complicated, and sometimes a second surgery may be required. The Thyroid Nodule Impedance Measurement System (TN-IMS) consists of a metallic patch attached to submental skin and a G20 I.V. cannula inserted into the targeted nodules. Two impedance-based parameters named Z(1kHz) and impedance phase slope (IPS) in 100 kHz to 500 kHz of the thyroid nodules are recorded and compared with their histopathological results as the gold standard. TN-IMS was intra-surgically applied to 103 human thyroid nodules and normal thyroid tissues. A remarkable consistency between defined co-ranges of Z(1kHz)/IPS and the histopathological status of specimens was achieved (p < 0.001). Based on these measurements, it was concluded that intraoperative bioelectrical impedance scanning of thyroid nodules would be a helpful complementary approach to detecting high-risk excision-required thyroid nodules.
format Online
Article
Text
id pubmed-9776834
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97768342022-12-23 Intraoperative Assessment of High-Risk Thyroid Nodules Based on Electrical Impedance Measurements: A Feasibility Study Beheshti Firoozabadi, Jalil Mahdavi, Reihane Shamsi, Khosro Ataee, Hossein Shafiee, Abdollah Ebrahiminik, Hojat Chegini, Hossein Hoseinpour, Parisa Moradi, Afshin Yousefpour, Narges Aghaei, Faeze Fardoost, Ali Ghelichli, Alireza Mokhtari Dowlatabad, Hadi Hajighasemi, Farzane Sami, Nafiseh Rouhollah Miri, Seyed Akbari, Mohammad Esmaeil Abdolahad, Mohammad Diagnostics (Basel) Article Precise diagnosis of thyroid nodules is challenging due to non-diagnostic/inconclusive results and uncertainties about the malignancy of follicular neoplasms (FNs), even in frozen-section pathology. Therefore, surgical management, especially in Bethesda III and IV categories, may be complicated, and sometimes a second surgery may be required. The Thyroid Nodule Impedance Measurement System (TN-IMS) consists of a metallic patch attached to submental skin and a G20 I.V. cannula inserted into the targeted nodules. Two impedance-based parameters named Z(1kHz) and impedance phase slope (IPS) in 100 kHz to 500 kHz of the thyroid nodules are recorded and compared with their histopathological results as the gold standard. TN-IMS was intra-surgically applied to 103 human thyroid nodules and normal thyroid tissues. A remarkable consistency between defined co-ranges of Z(1kHz)/IPS and the histopathological status of specimens was achieved (p < 0.001). Based on these measurements, it was concluded that intraoperative bioelectrical impedance scanning of thyroid nodules would be a helpful complementary approach to detecting high-risk excision-required thyroid nodules. MDPI 2022-11-25 /pmc/articles/PMC9776834/ /pubmed/36552958 http://dx.doi.org/10.3390/diagnostics12122950 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Beheshti Firoozabadi, Jalil
Mahdavi, Reihane
Shamsi, Khosro
Ataee, Hossein
Shafiee, Abdollah
Ebrahiminik, Hojat
Chegini, Hossein
Hoseinpour, Parisa
Moradi, Afshin
Yousefpour, Narges
Aghaei, Faeze
Fardoost, Ali
Ghelichli, Alireza
Mokhtari Dowlatabad, Hadi
Hajighasemi, Farzane
Sami, Nafiseh
Rouhollah Miri, Seyed
Akbari, Mohammad Esmaeil
Abdolahad, Mohammad
Intraoperative Assessment of High-Risk Thyroid Nodules Based on Electrical Impedance Measurements: A Feasibility Study
title Intraoperative Assessment of High-Risk Thyroid Nodules Based on Electrical Impedance Measurements: A Feasibility Study
title_full Intraoperative Assessment of High-Risk Thyroid Nodules Based on Electrical Impedance Measurements: A Feasibility Study
title_fullStr Intraoperative Assessment of High-Risk Thyroid Nodules Based on Electrical Impedance Measurements: A Feasibility Study
title_full_unstemmed Intraoperative Assessment of High-Risk Thyroid Nodules Based on Electrical Impedance Measurements: A Feasibility Study
title_short Intraoperative Assessment of High-Risk Thyroid Nodules Based on Electrical Impedance Measurements: A Feasibility Study
title_sort intraoperative assessment of high-risk thyroid nodules based on electrical impedance measurements: a feasibility study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9776834/
https://www.ncbi.nlm.nih.gov/pubmed/36552958
http://dx.doi.org/10.3390/diagnostics12122950
work_keys_str_mv AT beheshtifiroozabadijalil intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT mahdavireihane intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT shamsikhosro intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT ataeehossein intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT shafieeabdollah intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT ebrahiminikhojat intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT cheginihossein intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT hoseinpourparisa intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT moradiafshin intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT yousefpournarges intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT aghaeifaeze intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT fardoostali intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT ghelichlialireza intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT mokhtaridowlatabadhadi intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT hajighasemifarzane intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT saminafiseh intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT rouhollahmiriseyed intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT akbarimohammadesmaeil intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy
AT abdolahadmohammad intraoperativeassessmentofhighriskthyroidnodulesbasedonelectricalimpedancemeasurementsafeasibilitystudy