Cargando…
Soleris(®) Automated System for the Rapid Detection of Burkholderia cepacia Complex in Cosmetic Products
BACKGROUND: Burkholderia cepacia complex (Bcc) has emerged as an important opportunistic pathogen with rising concern in pharmaceuticals and cosmetic products. The Bcc supplement (S2-BCC-S) was purposely developed and used with the Pseudomonas vial (PD-109) for the detection of Bcc through the Soler...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9779911/ https://www.ncbi.nlm.nih.gov/pubmed/36130279 http://dx.doi.org/10.1093/jaoacint/qsac109 |
_version_ | 1784856726670934016 |
---|---|
author | Zhang, Lei Tolan, Jerry Lavigne, Nicholas Montei, Carolyn Donofrio, Robert Biswas, Preetha |
author_facet | Zhang, Lei Tolan, Jerry Lavigne, Nicholas Montei, Carolyn Donofrio, Robert Biswas, Preetha |
author_sort | Zhang, Lei |
collection | PubMed |
description | BACKGROUND: Burkholderia cepacia complex (Bcc) has emerged as an important opportunistic pathogen with rising concern in pharmaceuticals and cosmetic products. The Bcc supplement (S2-BCC-S) was purposely developed and used with the Pseudomonas vial (PD-109) for the detection of Bcc through the Soleris(®) Next Generation automated instrument system. OBJECTIVE: This study aimed to evaluate the performance of the Soleris Bcc testing method for cosmetic products. METHOD: Inclusivity and exclusivity were assessed with the Soleris Bcc method and the United States Pharmacopeia (USP) method in three enrichment broths. Matrix testing was conducted using 28 cosmetic products to compare the equivalency of the Soleris Bcc method to that of the USP reference method. Repeatability of the Soleris Bcc assay, method robustness, product stability, and lot-to-lot consistency of the Soleris reagents were also assessed. RESULTS: Both the Soleris Bcc and the USP methods supported the growth of all 26 inclusivity strains, except the USP method missed one inclusivity strain in one broth. For exclusivity, 0–6% was presumptive positive with the Soleris Bcc method, and 42–48% was presumptive positive with the reference method. Kappa index was 0.96 for the matrix testing, indicating a good agreement between the Soleris Bcc assay and the reference method for testing Bcc in cosmetics. Repeatability results showed the coefficient of variation was less than 4%. The robustness and ruggedness study yielded detection times within 1 h differences when small variations were introduced. The lot-to-lot study showed consistent results among four lots of the Bcc reagents. CONCLUSIONS: The automated Soleris method was successfully demonstrated to be robust, sensitive, and specific for Bcc detection in cosmetic products. HIGHLIGHTS: The Soleris Bcc method is user-friendly. It shows the results in real time and generates the report automatically. Implementation of this method for detection of Bcc in cosmetics would save significant time and resources. |
format | Online Article Text |
id | pubmed-9779911 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-97799112022-12-23 Soleris(®) Automated System for the Rapid Detection of Burkholderia cepacia Complex in Cosmetic Products Zhang, Lei Tolan, Jerry Lavigne, Nicholas Montei, Carolyn Donofrio, Robert Biswas, Preetha J AOAC Int Research Article BACKGROUND: Burkholderia cepacia complex (Bcc) has emerged as an important opportunistic pathogen with rising concern in pharmaceuticals and cosmetic products. The Bcc supplement (S2-BCC-S) was purposely developed and used with the Pseudomonas vial (PD-109) for the detection of Bcc through the Soleris(®) Next Generation automated instrument system. OBJECTIVE: This study aimed to evaluate the performance of the Soleris Bcc testing method for cosmetic products. METHOD: Inclusivity and exclusivity were assessed with the Soleris Bcc method and the United States Pharmacopeia (USP) method in three enrichment broths. Matrix testing was conducted using 28 cosmetic products to compare the equivalency of the Soleris Bcc method to that of the USP reference method. Repeatability of the Soleris Bcc assay, method robustness, product stability, and lot-to-lot consistency of the Soleris reagents were also assessed. RESULTS: Both the Soleris Bcc and the USP methods supported the growth of all 26 inclusivity strains, except the USP method missed one inclusivity strain in one broth. For exclusivity, 0–6% was presumptive positive with the Soleris Bcc method, and 42–48% was presumptive positive with the reference method. Kappa index was 0.96 for the matrix testing, indicating a good agreement between the Soleris Bcc assay and the reference method for testing Bcc in cosmetics. Repeatability results showed the coefficient of variation was less than 4%. The robustness and ruggedness study yielded detection times within 1 h differences when small variations were introduced. The lot-to-lot study showed consistent results among four lots of the Bcc reagents. CONCLUSIONS: The automated Soleris method was successfully demonstrated to be robust, sensitive, and specific for Bcc detection in cosmetic products. HIGHLIGHTS: The Soleris Bcc method is user-friendly. It shows the results in real time and generates the report automatically. Implementation of this method for detection of Bcc in cosmetics would save significant time and resources. Oxford University Press 2022-09-21 /pmc/articles/PMC9779911/ /pubmed/36130279 http://dx.doi.org/10.1093/jaoacint/qsac109 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of AOAC INTERNATIONAL. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Zhang, Lei Tolan, Jerry Lavigne, Nicholas Montei, Carolyn Donofrio, Robert Biswas, Preetha Soleris(®) Automated System for the Rapid Detection of Burkholderia cepacia Complex in Cosmetic Products |
title | Soleris(®) Automated System for the Rapid Detection of Burkholderia cepacia Complex in Cosmetic Products |
title_full | Soleris(®) Automated System for the Rapid Detection of Burkholderia cepacia Complex in Cosmetic Products |
title_fullStr | Soleris(®) Automated System for the Rapid Detection of Burkholderia cepacia Complex in Cosmetic Products |
title_full_unstemmed | Soleris(®) Automated System for the Rapid Detection of Burkholderia cepacia Complex in Cosmetic Products |
title_short | Soleris(®) Automated System for the Rapid Detection of Burkholderia cepacia Complex in Cosmetic Products |
title_sort | soleris(®) automated system for the rapid detection of burkholderia cepacia complex in cosmetic products |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9779911/ https://www.ncbi.nlm.nih.gov/pubmed/36130279 http://dx.doi.org/10.1093/jaoacint/qsac109 |
work_keys_str_mv | AT zhanglei solerisautomatedsystemfortherapiddetectionofburkholderiacepaciacomplexincosmeticproducts AT tolanjerry solerisautomatedsystemfortherapiddetectionofburkholderiacepaciacomplexincosmeticproducts AT lavignenicholas solerisautomatedsystemfortherapiddetectionofburkholderiacepaciacomplexincosmeticproducts AT monteicarolyn solerisautomatedsystemfortherapiddetectionofburkholderiacepaciacomplexincosmeticproducts AT donofriorobert solerisautomatedsystemfortherapiddetectionofburkholderiacepaciacomplexincosmeticproducts AT biswaspreetha solerisautomatedsystemfortherapiddetectionofburkholderiacepaciacomplexincosmeticproducts |