Cargando…

Development and preclinical evaluation of a cable-clamp fixation device for a disrupted pubic symphysis

BACKGROUND: Traumatic separation of the pubic symphysis can destabilize the pelvis and require surgical fixation to reduce symphyseal gapping. The traditional approach involves open reduction and the implantation of a steel symphyseal plate (SP) on the pubic bone to hold the reposition. Despite its...

Descripción completa

Detalles Bibliográficos
Autores principales: Jordan, Martin C., Bröer, David, Fischer, Christian, Heilig, Philipp, Gilbert, Fabian, Hölscher-Doht, Stefanie, Kalogirou, Charis, Popp, Kevin, Grunz, Jan-Peter, Huflage, Henner, Jakubietz, Rafael G., Ergün, Süleyman, Meffert, Rainer H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9780275/
https://www.ncbi.nlm.nih.gov/pubmed/36550296
http://dx.doi.org/10.1038/s43856-022-00227-z
Descripción
Sumario:BACKGROUND: Traumatic separation of the pubic symphysis can destabilize the pelvis and require surgical fixation to reduce symphyseal gapping. The traditional approach involves open reduction and the implantation of a steel symphyseal plate (SP) on the pubic bone to hold the reposition. Despite its widespread use, SP-fixation is often associated with implant failure caused by screw loosening or breakage. METHODS: To address the need for a more reliable surgical intervention, we developed and tested two titanium cable-clamp implants. The cable served as tensioning device while the clamp secured the cable to the bone. The first implant design included a steel cable anterior to the pubic symphysis to simplify its placement outside the pelvis, and the second design included a cable encircling the pubic symphysis to stabilize the anterior pelvic ring. Using highly reproducible synthetic bone models and a limited number of cadaver specimens, we performed a comprehensive biomechanical study of implant stability and evaluated surgical feasibility. RESULTS: We were able to demonstrate that the cable-clamp implants provide stability equivalent to that of a traditional SP-fixation but without the same risks of implant failure. We also provide detailed ex vivo evaluations of the safety and feasibility of a trans-obturator surgical approach required for those kind of fixation. CONCLUSION: We propose that the developed cable-clamp fixation devices may be of clinical value in treating pubic symphysis separation.