Study on the Control Method of Sidewall Taper in Electrolytic Broaching of Micro Multi-Grooves
Micro multi-grooves are important functional structures widely used in new heat exchanger types, chemical reactors, and other applications. Electrolytic broaching is an efficient and low-cost technology for processing micro multi-grooves. In the conventional electrolytic broaching of multi-grooves,...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9781269/ https://www.ncbi.nlm.nih.gov/pubmed/36557361 http://dx.doi.org/10.3390/mi13122062 |
_version_ | 1784857032538456064 |
---|---|
author | Liu, Jia Wu, Hao Gao, Feng |
author_facet | Liu, Jia Wu, Hao Gao, Feng |
author_sort | Liu, Jia |
collection | PubMed |
description | Micro multi-grooves are important functional structures widely used in new heat exchanger types, chemical reactors, and other applications. Electrolytic broaching is an efficient and low-cost technology for processing micro multi-grooves. In the conventional electrolytic broaching of multi-grooves, the cathode tools are usually designed as a wedge-shaped tooth structure array with a constant tooth width, and the sidewalls are covered with insulating layers. The machined groove sidewall is always tapered because of stray current corrosion, which strongly affects the groove contour accuracy. Cathode tools with variable tooth width structures are proposed to solve this problem. Based on the simulation results of the electrolytic broaching anode forming process, the optimal front tooth width is obtained through the golden section optimization method, and comparative tests of the conventional and optimized cathode tools were carried out. At an electrochemical broaching feed rate of 120 mm/min, array microgrooves with widths of about 550 μm and depths of about 520 μm were processed. With the optimized variable tooth width tool, the sidewall tapers of the grooves were reduced from 7.254° to 0.268°. The experimental results verify the effectiveness of the simulation and cathode structure optimization. |
format | Online Article Text |
id | pubmed-9781269 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-97812692022-12-24 Study on the Control Method of Sidewall Taper in Electrolytic Broaching of Micro Multi-Grooves Liu, Jia Wu, Hao Gao, Feng Micromachines (Basel) Article Micro multi-grooves are important functional structures widely used in new heat exchanger types, chemical reactors, and other applications. Electrolytic broaching is an efficient and low-cost technology for processing micro multi-grooves. In the conventional electrolytic broaching of multi-grooves, the cathode tools are usually designed as a wedge-shaped tooth structure array with a constant tooth width, and the sidewalls are covered with insulating layers. The machined groove sidewall is always tapered because of stray current corrosion, which strongly affects the groove contour accuracy. Cathode tools with variable tooth width structures are proposed to solve this problem. Based on the simulation results of the electrolytic broaching anode forming process, the optimal front tooth width is obtained through the golden section optimization method, and comparative tests of the conventional and optimized cathode tools were carried out. At an electrochemical broaching feed rate of 120 mm/min, array microgrooves with widths of about 550 μm and depths of about 520 μm were processed. With the optimized variable tooth width tool, the sidewall tapers of the grooves were reduced from 7.254° to 0.268°. The experimental results verify the effectiveness of the simulation and cathode structure optimization. MDPI 2022-11-24 /pmc/articles/PMC9781269/ /pubmed/36557361 http://dx.doi.org/10.3390/mi13122062 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Liu, Jia Wu, Hao Gao, Feng Study on the Control Method of Sidewall Taper in Electrolytic Broaching of Micro Multi-Grooves |
title | Study on the Control Method of Sidewall Taper in Electrolytic Broaching of Micro Multi-Grooves |
title_full | Study on the Control Method of Sidewall Taper in Electrolytic Broaching of Micro Multi-Grooves |
title_fullStr | Study on the Control Method of Sidewall Taper in Electrolytic Broaching of Micro Multi-Grooves |
title_full_unstemmed | Study on the Control Method of Sidewall Taper in Electrolytic Broaching of Micro Multi-Grooves |
title_short | Study on the Control Method of Sidewall Taper in Electrolytic Broaching of Micro Multi-Grooves |
title_sort | study on the control method of sidewall taper in electrolytic broaching of micro multi-grooves |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9781269/ https://www.ncbi.nlm.nih.gov/pubmed/36557361 http://dx.doi.org/10.3390/mi13122062 |
work_keys_str_mv | AT liujia studyonthecontrolmethodofsidewalltaperinelectrolyticbroachingofmicromultigrooves AT wuhao studyonthecontrolmethodofsidewalltaperinelectrolyticbroachingofmicromultigrooves AT gaofeng studyonthecontrolmethodofsidewalltaperinelectrolyticbroachingofmicromultigrooves |