Effect of Local Annealing on Magnetic Flux Distribution and Noise in a Micro-Generator with Amorphous Shell

This study examined micro-alternators with two different housing structures––an uncoated shell and a shell coated with an iron-based amorphous-alloy soft magnetic material. The electromagnetic power and noise characteristics of generators with these shell structures were measured and analyzed. The m...

Descripción completa

Detalles Bibliográficos
Autor principal: Hsu, Chang-Hung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9781415/
https://www.ncbi.nlm.nih.gov/pubmed/36557384
http://dx.doi.org/10.3390/mi13122086
_version_ 1784857068665044992
author Hsu, Chang-Hung
author_facet Hsu, Chang-Hung
author_sort Hsu, Chang-Hung
collection PubMed
description This study examined micro-alternators with two different housing structures––an uncoated shell and a shell coated with an iron-based amorphous-alloy soft magnetic material. The electromagnetic power and noise characteristics of generators with these shell structures were measured and analyzed. The material used for the shell coating was the SA1 amorphous alloy. The magnetic property of the SA1 material was evaluated, including its hysteresis expansion, hysteresis-loop parameters, α-Fe crystal formation, thermogravimetric transfer, and Curie temperature. The center point of the casing was subjected to flame local-heating annealing to attain ferromagnetism and paramagnetism material characteristics. The experimental shell was between these magnetic-phase-transition properties and was used to observe the magnetic power and noise characteristics of the microgenerator. The measured magnetic flux at the center of the amorphous shell was 1.2–2.4 mT, and the magnetic flux distributed around the shell was 0.6–1.0 mT. The generator with the amorphous-alloy shell had the lowest demagnetization rate in the permanent magnet region, which was close to the bottom of the pole piece, and the magnetic flux leakage of the pole-piece side frame changed the magnetic flux path, thus affecting the demagnetization performance. For the noise experiment, the flame-annealing temperature of the local center point of the amorphous casing reached the Curie temperature, and the noise characteristics of the casing can be reduced by 15 dB compared to those of the generator without the casing. However, the overall performance of generator harmonics and power were not fully improved.
format Online
Article
Text
id pubmed-9781415
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97814152022-12-24 Effect of Local Annealing on Magnetic Flux Distribution and Noise in a Micro-Generator with Amorphous Shell Hsu, Chang-Hung Micromachines (Basel) Article This study examined micro-alternators with two different housing structures––an uncoated shell and a shell coated with an iron-based amorphous-alloy soft magnetic material. The electromagnetic power and noise characteristics of generators with these shell structures were measured and analyzed. The material used for the shell coating was the SA1 amorphous alloy. The magnetic property of the SA1 material was evaluated, including its hysteresis expansion, hysteresis-loop parameters, α-Fe crystal formation, thermogravimetric transfer, and Curie temperature. The center point of the casing was subjected to flame local-heating annealing to attain ferromagnetism and paramagnetism material characteristics. The experimental shell was between these magnetic-phase-transition properties and was used to observe the magnetic power and noise characteristics of the microgenerator. The measured magnetic flux at the center of the amorphous shell was 1.2–2.4 mT, and the magnetic flux distributed around the shell was 0.6–1.0 mT. The generator with the amorphous-alloy shell had the lowest demagnetization rate in the permanent magnet region, which was close to the bottom of the pole piece, and the magnetic flux leakage of the pole-piece side frame changed the magnetic flux path, thus affecting the demagnetization performance. For the noise experiment, the flame-annealing temperature of the local center point of the amorphous casing reached the Curie temperature, and the noise characteristics of the casing can be reduced by 15 dB compared to those of the generator without the casing. However, the overall performance of generator harmonics and power were not fully improved. MDPI 2022-11-26 /pmc/articles/PMC9781415/ /pubmed/36557384 http://dx.doi.org/10.3390/mi13122086 Text en © 2022 by the author. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hsu, Chang-Hung
Effect of Local Annealing on Magnetic Flux Distribution and Noise in a Micro-Generator with Amorphous Shell
title Effect of Local Annealing on Magnetic Flux Distribution and Noise in a Micro-Generator with Amorphous Shell
title_full Effect of Local Annealing on Magnetic Flux Distribution and Noise in a Micro-Generator with Amorphous Shell
title_fullStr Effect of Local Annealing on Magnetic Flux Distribution and Noise in a Micro-Generator with Amorphous Shell
title_full_unstemmed Effect of Local Annealing on Magnetic Flux Distribution and Noise in a Micro-Generator with Amorphous Shell
title_short Effect of Local Annealing on Magnetic Flux Distribution and Noise in a Micro-Generator with Amorphous Shell
title_sort effect of local annealing on magnetic flux distribution and noise in a micro-generator with amorphous shell
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9781415/
https://www.ncbi.nlm.nih.gov/pubmed/36557384
http://dx.doi.org/10.3390/mi13122086
work_keys_str_mv AT hsuchanghung effectoflocalannealingonmagneticfluxdistributionandnoiseinamicrogeneratorwithamorphousshell