Cargando…
Long-Term Outcome of Infective Endocarditis Involving Cardiac Implantable Electronic Devices: Impact of Comorbidities and Lead Extraction
(1) Background: Management of cardiac implantable electronic device-related infective endocarditis (CIED-IE) hinges on complete hardware removal. We assessed whether long-term prognosis is affected by device removal, considering baseline patient comorbid conditions; (2) Methods: A total of 125 conse...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9781771/ https://www.ncbi.nlm.nih.gov/pubmed/36555974 http://dx.doi.org/10.3390/jcm11247357 |
_version_ | 1784857155863576576 |
---|---|
author | Durante-Mangoni, Emanuele Ursi, Maria Paola Andini, Roberto Mattucci, Irene Della Ratta, Ester E. Iossa, Domenico Bertolino, Lorenzo De Vivo, Stefano Manduca, Sabrina Torella, Michele De Feo, Marisa Zampino, Rosa |
author_facet | Durante-Mangoni, Emanuele Ursi, Maria Paola Andini, Roberto Mattucci, Irene Della Ratta, Ester E. Iossa, Domenico Bertolino, Lorenzo De Vivo, Stefano Manduca, Sabrina Torella, Michele De Feo, Marisa Zampino, Rosa |
author_sort | Durante-Mangoni, Emanuele |
collection | PubMed |
description | (1) Background: Management of cardiac implantable electronic device-related infective endocarditis (CIED-IE) hinges on complete hardware removal. We assessed whether long-term prognosis is affected by device removal, considering baseline patient comorbid conditions; (2) Methods: A total of 125 consecutive patients hospitalized for CIED-IE were included in this retrospective analysis. Outcomes were in-hospital, one-year, and long-term mortality. There were 109 patients who underwent device removal, 91 by transvenous lead extraction (TLE) and 18 by open heart surgery (OHS); (3) Results: TLE translated into lower hospital mortality (4.4% vs. 22.5% with OHS; p = 0.03). Septic pulmonary embolism was the only independent predictor of in-hospital mortality (OR:7.38 [1.49–36.6], p = 0.013). One-year mortality was in contrast independently associated to tricuspid valve involvement (p = 0.01) and Charlson comorbidity index (CCI, p = 0.039), but not the hardware removal modality. After a median follow-up of 41 months, mortality rose to 24%, and was significantly influenced only by CCI. Specifically, patients with a higher CCI who were also treated with TLE showed a survival rate not significantly different from those managed with medical therapy only; (4) Conclusions: In CIED-IE, TLE is the strategy of choice for hardware removal, improving early outcomes. Long-term benefits of TLE are lessened by comorbidities. In cases of CIED-IE with high CCI, a more conservative approach might be an option. |
format | Online Article Text |
id | pubmed-9781771 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-97817712022-12-24 Long-Term Outcome of Infective Endocarditis Involving Cardiac Implantable Electronic Devices: Impact of Comorbidities and Lead Extraction Durante-Mangoni, Emanuele Ursi, Maria Paola Andini, Roberto Mattucci, Irene Della Ratta, Ester E. Iossa, Domenico Bertolino, Lorenzo De Vivo, Stefano Manduca, Sabrina Torella, Michele De Feo, Marisa Zampino, Rosa J Clin Med Article (1) Background: Management of cardiac implantable electronic device-related infective endocarditis (CIED-IE) hinges on complete hardware removal. We assessed whether long-term prognosis is affected by device removal, considering baseline patient comorbid conditions; (2) Methods: A total of 125 consecutive patients hospitalized for CIED-IE were included in this retrospective analysis. Outcomes were in-hospital, one-year, and long-term mortality. There were 109 patients who underwent device removal, 91 by transvenous lead extraction (TLE) and 18 by open heart surgery (OHS); (3) Results: TLE translated into lower hospital mortality (4.4% vs. 22.5% with OHS; p = 0.03). Septic pulmonary embolism was the only independent predictor of in-hospital mortality (OR:7.38 [1.49–36.6], p = 0.013). One-year mortality was in contrast independently associated to tricuspid valve involvement (p = 0.01) and Charlson comorbidity index (CCI, p = 0.039), but not the hardware removal modality. After a median follow-up of 41 months, mortality rose to 24%, and was significantly influenced only by CCI. Specifically, patients with a higher CCI who were also treated with TLE showed a survival rate not significantly different from those managed with medical therapy only; (4) Conclusions: In CIED-IE, TLE is the strategy of choice for hardware removal, improving early outcomes. Long-term benefits of TLE are lessened by comorbidities. In cases of CIED-IE with high CCI, a more conservative approach might be an option. MDPI 2022-12-11 /pmc/articles/PMC9781771/ /pubmed/36555974 http://dx.doi.org/10.3390/jcm11247357 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Durante-Mangoni, Emanuele Ursi, Maria Paola Andini, Roberto Mattucci, Irene Della Ratta, Ester E. Iossa, Domenico Bertolino, Lorenzo De Vivo, Stefano Manduca, Sabrina Torella, Michele De Feo, Marisa Zampino, Rosa Long-Term Outcome of Infective Endocarditis Involving Cardiac Implantable Electronic Devices: Impact of Comorbidities and Lead Extraction |
title | Long-Term Outcome of Infective Endocarditis Involving Cardiac Implantable Electronic Devices: Impact of Comorbidities and Lead Extraction |
title_full | Long-Term Outcome of Infective Endocarditis Involving Cardiac Implantable Electronic Devices: Impact of Comorbidities and Lead Extraction |
title_fullStr | Long-Term Outcome of Infective Endocarditis Involving Cardiac Implantable Electronic Devices: Impact of Comorbidities and Lead Extraction |
title_full_unstemmed | Long-Term Outcome of Infective Endocarditis Involving Cardiac Implantable Electronic Devices: Impact of Comorbidities and Lead Extraction |
title_short | Long-Term Outcome of Infective Endocarditis Involving Cardiac Implantable Electronic Devices: Impact of Comorbidities and Lead Extraction |
title_sort | long-term outcome of infective endocarditis involving cardiac implantable electronic devices: impact of comorbidities and lead extraction |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9781771/ https://www.ncbi.nlm.nih.gov/pubmed/36555974 http://dx.doi.org/10.3390/jcm11247357 |
work_keys_str_mv | AT durantemangoniemanuele longtermoutcomeofinfectiveendocarditisinvolvingcardiacimplantableelectronicdevicesimpactofcomorbiditiesandleadextraction AT ursimariapaola longtermoutcomeofinfectiveendocarditisinvolvingcardiacimplantableelectronicdevicesimpactofcomorbiditiesandleadextraction AT andiniroberto longtermoutcomeofinfectiveendocarditisinvolvingcardiacimplantableelectronicdevicesimpactofcomorbiditiesandleadextraction AT mattucciirene longtermoutcomeofinfectiveendocarditisinvolvingcardiacimplantableelectronicdevicesimpactofcomorbiditiesandleadextraction AT dellarattaestere longtermoutcomeofinfectiveendocarditisinvolvingcardiacimplantableelectronicdevicesimpactofcomorbiditiesandleadextraction AT iossadomenico longtermoutcomeofinfectiveendocarditisinvolvingcardiacimplantableelectronicdevicesimpactofcomorbiditiesandleadextraction AT bertolinolorenzo longtermoutcomeofinfectiveendocarditisinvolvingcardiacimplantableelectronicdevicesimpactofcomorbiditiesandleadextraction AT devivostefano longtermoutcomeofinfectiveendocarditisinvolvingcardiacimplantableelectronicdevicesimpactofcomorbiditiesandleadextraction AT manducasabrina longtermoutcomeofinfectiveendocarditisinvolvingcardiacimplantableelectronicdevicesimpactofcomorbiditiesandleadextraction AT torellamichele longtermoutcomeofinfectiveendocarditisinvolvingcardiacimplantableelectronicdevicesimpactofcomorbiditiesandleadextraction AT defeomarisa longtermoutcomeofinfectiveendocarditisinvolvingcardiacimplantableelectronicdevicesimpactofcomorbiditiesandleadextraction AT zampinorosa longtermoutcomeofinfectiveendocarditisinvolvingcardiacimplantableelectronicdevicesimpactofcomorbiditiesandleadextraction AT longtermoutcomeofinfectiveendocarditisinvolvingcardiacimplantableelectronicdevicesimpactofcomorbiditiesandleadextraction |