Taper-wedge stem suitable for anterior approach total hip arthroplasty: Adequate biomechanical reconstruction parameters and excellent clinical outcome at mid-term follow-up
BACKGROUND: The direct anterior approach (DAA) for total hip arthroplasty (THA) is a less invasive and muscle-sparing approach that seems to improve early function and patient satisfaction. Several studies, however, have reported high complication and revision rates due to the technical difficulties...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Baishideng Publishing Group Inc
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9782544/ https://www.ncbi.nlm.nih.gov/pubmed/36567862 http://dx.doi.org/10.5312/wjo.v13.i12.1047 |
_version_ | 1784857368466554880 |
---|---|
author | Trevisan, Carlo Lombardo, Antonino Salvatore Gallinari, Gianluca Zeppieri, Marco Klumpp, Raymond |
author_facet | Trevisan, Carlo Lombardo, Antonino Salvatore Gallinari, Gianluca Zeppieri, Marco Klumpp, Raymond |
author_sort | Trevisan, Carlo |
collection | PubMed |
description | BACKGROUND: The direct anterior approach (DAA) for total hip arthroplasty (THA) is a less invasive and muscle-sparing approach that seems to improve early function and patient satisfaction. Several studies, however, have reported high complication and revision rates due to the technical difficulties related to the femoral preparation. AIM: To evaluate the usefulness and safety of a new stem equipped with a morphometric design and a size-specific medial curvature in DAA for THA. METHODS: This retrospective study was based on 130 patients that underwent mini-invasive DAA procedures for THA using the Accolade II stem. A total of 144 procedures were included in the assessment, which was based on postoperative complications, survival rates, functional parameters, and patient related outcomes. RESULTS: Overall complications were recorded in 6 procedures (4.2%). There were no complications related to the stem implantation and no intraoperative fractures. Only one patient was revised for deep infection. On radiographs, biomechanical hip reconstruction was satisfactory and no stem showed any subsidence greater than 2 mm. Full osseointegration based on Engh scores was seen in all of the implanted stems. Median Harris hip score at final follow-up was 99 points (range 44-100 points), which resulted excellent in 91.3% of patients. The median values of the osteaorthritis outcome score ranged from 87.5 to 95. CONCLUSION: The mid-term positive outcomes and low complication rate in our consecutive series of patients support the safety and suitability of this new stem design in DAA for THA. |
format | Online Article Text |
id | pubmed-9782544 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Baishideng Publishing Group Inc |
record_format | MEDLINE/PubMed |
spelling | pubmed-97825442022-12-24 Taper-wedge stem suitable for anterior approach total hip arthroplasty: Adequate biomechanical reconstruction parameters and excellent clinical outcome at mid-term follow-up Trevisan, Carlo Lombardo, Antonino Salvatore Gallinari, Gianluca Zeppieri, Marco Klumpp, Raymond World J Orthop Retrospective Study BACKGROUND: The direct anterior approach (DAA) for total hip arthroplasty (THA) is a less invasive and muscle-sparing approach that seems to improve early function and patient satisfaction. Several studies, however, have reported high complication and revision rates due to the technical difficulties related to the femoral preparation. AIM: To evaluate the usefulness and safety of a new stem equipped with a morphometric design and a size-specific medial curvature in DAA for THA. METHODS: This retrospective study was based on 130 patients that underwent mini-invasive DAA procedures for THA using the Accolade II stem. A total of 144 procedures were included in the assessment, which was based on postoperative complications, survival rates, functional parameters, and patient related outcomes. RESULTS: Overall complications were recorded in 6 procedures (4.2%). There were no complications related to the stem implantation and no intraoperative fractures. Only one patient was revised for deep infection. On radiographs, biomechanical hip reconstruction was satisfactory and no stem showed any subsidence greater than 2 mm. Full osseointegration based on Engh scores was seen in all of the implanted stems. Median Harris hip score at final follow-up was 99 points (range 44-100 points), which resulted excellent in 91.3% of patients. The median values of the osteaorthritis outcome score ranged from 87.5 to 95. CONCLUSION: The mid-term positive outcomes and low complication rate in our consecutive series of patients support the safety and suitability of this new stem design in DAA for THA. Baishideng Publishing Group Inc 2022-12-18 /pmc/articles/PMC9782544/ /pubmed/36567862 http://dx.doi.org/10.5312/wjo.v13.i12.1047 Text en ©The Author(s) 2022. Published by Baishideng Publishing Group Inc. All rights reserved. https://creativecommons.org/licenses/by-nc/4.0/This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/Licenses/by-nc/4.0/ |
spellingShingle | Retrospective Study Trevisan, Carlo Lombardo, Antonino Salvatore Gallinari, Gianluca Zeppieri, Marco Klumpp, Raymond Taper-wedge stem suitable for anterior approach total hip arthroplasty: Adequate biomechanical reconstruction parameters and excellent clinical outcome at mid-term follow-up |
title | Taper-wedge stem suitable for anterior approach total hip arthroplasty: Adequate biomechanical reconstruction parameters and excellent clinical outcome at mid-term follow-up |
title_full | Taper-wedge stem suitable for anterior approach total hip arthroplasty: Adequate biomechanical reconstruction parameters and excellent clinical outcome at mid-term follow-up |
title_fullStr | Taper-wedge stem suitable for anterior approach total hip arthroplasty: Adequate biomechanical reconstruction parameters and excellent clinical outcome at mid-term follow-up |
title_full_unstemmed | Taper-wedge stem suitable for anterior approach total hip arthroplasty: Adequate biomechanical reconstruction parameters and excellent clinical outcome at mid-term follow-up |
title_short | Taper-wedge stem suitable for anterior approach total hip arthroplasty: Adequate biomechanical reconstruction parameters and excellent clinical outcome at mid-term follow-up |
title_sort | taper-wedge stem suitable for anterior approach total hip arthroplasty: adequate biomechanical reconstruction parameters and excellent clinical outcome at mid-term follow-up |
topic | Retrospective Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9782544/ https://www.ncbi.nlm.nih.gov/pubmed/36567862 http://dx.doi.org/10.5312/wjo.v13.i12.1047 |
work_keys_str_mv | AT trevisancarlo taperwedgestemsuitableforanteriorapproachtotalhiparthroplastyadequatebiomechanicalreconstructionparametersandexcellentclinicaloutcomeatmidtermfollowup AT lombardoantoninosalvatore taperwedgestemsuitableforanteriorapproachtotalhiparthroplastyadequatebiomechanicalreconstructionparametersandexcellentclinicaloutcomeatmidtermfollowup AT gallinarigianluca taperwedgestemsuitableforanteriorapproachtotalhiparthroplastyadequatebiomechanicalreconstructionparametersandexcellentclinicaloutcomeatmidtermfollowup AT zeppierimarco taperwedgestemsuitableforanteriorapproachtotalhiparthroplastyadequatebiomechanicalreconstructionparametersandexcellentclinicaloutcomeatmidtermfollowup AT klumppraymond taperwedgestemsuitableforanteriorapproachtotalhiparthroplastyadequatebiomechanicalreconstructionparametersandexcellentclinicaloutcomeatmidtermfollowup |