Cargando…

Effect of Scanning Origin Location on Data Accuracy of Abutment Teeth Region in Digital Impression Acquired Using Intraoral Scanner for Removable Partial Denture: A Preliminary In Vitro Study

The aim of this study was to investigate the effect of scanning origin location on the data accuracy of removable partial denture (RPD) abutment teeth region in digital impressions acquired by an intraoral scanner. A mandibular partially edentulous model including the following target abutment teeth...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Eung-Yeol, Wada, Junichiro, Sakamoto, Kazuki, Ishioka, Yurika, Arai, Yuki, Murakami, Natsuko, Yamazaki, Toshiki, Hayama, Hironari, Utsumi, Miona, Inukai, Shusuke, Wakabayashi, Noriyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9783230/
https://www.ncbi.nlm.nih.gov/pubmed/36556008
http://dx.doi.org/10.3390/jcm11247392
_version_ 1784857528721473536
author Kim, Eung-Yeol
Wada, Junichiro
Sakamoto, Kazuki
Ishioka, Yurika
Arai, Yuki
Murakami, Natsuko
Yamazaki, Toshiki
Hayama, Hironari
Utsumi, Miona
Inukai, Shusuke
Wakabayashi, Noriyuki
author_facet Kim, Eung-Yeol
Wada, Junichiro
Sakamoto, Kazuki
Ishioka, Yurika
Arai, Yuki
Murakami, Natsuko
Yamazaki, Toshiki
Hayama, Hironari
Utsumi, Miona
Inukai, Shusuke
Wakabayashi, Noriyuki
author_sort Kim, Eung-Yeol
collection PubMed
description The aim of this study was to investigate the effect of scanning origin location on the data accuracy of removable partial denture (RPD) abutment teeth region in digital impressions acquired by an intraoral scanner. A mandibular partially edentulous model including the following target abutment teeth was used: the left second molar (#37); left first premolar (#34); and right second premolar (#45). The following scanning strategies were tested: the strategy starting from #37 to mesial direction (37M); strategies starting from #34 to mesial (34M) and distal directions (34D), and strategies starting from #45 to mesial (45M) and distal directions (45D). The evaluated measures were trueness, precision, and linear accuracy. One-way and two-way ANOVA were performed for the comparison of trueness and linear accuracy, while Kruskal–Wallis test was performed for the precision comparison (α = 0.05). 45M and 45D showed significantly superior trueness of #34 to 37M and 34D. 45M also showed significantly superior trueness of #45 to 34. 45D showed significantly inferior linear accuracy of #34 and superior linear accuracy of #45 compared to other strategies. It was concluded that scanning origin location would have an impact on data accuracy of RPD abutment teeth region in digital impressions acquired by intraoral scanner.
format Online
Article
Text
id pubmed-9783230
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97832302022-12-24 Effect of Scanning Origin Location on Data Accuracy of Abutment Teeth Region in Digital Impression Acquired Using Intraoral Scanner for Removable Partial Denture: A Preliminary In Vitro Study Kim, Eung-Yeol Wada, Junichiro Sakamoto, Kazuki Ishioka, Yurika Arai, Yuki Murakami, Natsuko Yamazaki, Toshiki Hayama, Hironari Utsumi, Miona Inukai, Shusuke Wakabayashi, Noriyuki J Clin Med Article The aim of this study was to investigate the effect of scanning origin location on the data accuracy of removable partial denture (RPD) abutment teeth region in digital impressions acquired by an intraoral scanner. A mandibular partially edentulous model including the following target abutment teeth was used: the left second molar (#37); left first premolar (#34); and right second premolar (#45). The following scanning strategies were tested: the strategy starting from #37 to mesial direction (37M); strategies starting from #34 to mesial (34M) and distal directions (34D), and strategies starting from #45 to mesial (45M) and distal directions (45D). The evaluated measures were trueness, precision, and linear accuracy. One-way and two-way ANOVA were performed for the comparison of trueness and linear accuracy, while Kruskal–Wallis test was performed for the precision comparison (α = 0.05). 45M and 45D showed significantly superior trueness of #34 to 37M and 34D. 45M also showed significantly superior trueness of #45 to 34. 45D showed significantly inferior linear accuracy of #34 and superior linear accuracy of #45 compared to other strategies. It was concluded that scanning origin location would have an impact on data accuracy of RPD abutment teeth region in digital impressions acquired by intraoral scanner. MDPI 2022-12-13 /pmc/articles/PMC9783230/ /pubmed/36556008 http://dx.doi.org/10.3390/jcm11247392 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kim, Eung-Yeol
Wada, Junichiro
Sakamoto, Kazuki
Ishioka, Yurika
Arai, Yuki
Murakami, Natsuko
Yamazaki, Toshiki
Hayama, Hironari
Utsumi, Miona
Inukai, Shusuke
Wakabayashi, Noriyuki
Effect of Scanning Origin Location on Data Accuracy of Abutment Teeth Region in Digital Impression Acquired Using Intraoral Scanner for Removable Partial Denture: A Preliminary In Vitro Study
title Effect of Scanning Origin Location on Data Accuracy of Abutment Teeth Region in Digital Impression Acquired Using Intraoral Scanner for Removable Partial Denture: A Preliminary In Vitro Study
title_full Effect of Scanning Origin Location on Data Accuracy of Abutment Teeth Region in Digital Impression Acquired Using Intraoral Scanner for Removable Partial Denture: A Preliminary In Vitro Study
title_fullStr Effect of Scanning Origin Location on Data Accuracy of Abutment Teeth Region in Digital Impression Acquired Using Intraoral Scanner for Removable Partial Denture: A Preliminary In Vitro Study
title_full_unstemmed Effect of Scanning Origin Location on Data Accuracy of Abutment Teeth Region in Digital Impression Acquired Using Intraoral Scanner for Removable Partial Denture: A Preliminary In Vitro Study
title_short Effect of Scanning Origin Location on Data Accuracy of Abutment Teeth Region in Digital Impression Acquired Using Intraoral Scanner for Removable Partial Denture: A Preliminary In Vitro Study
title_sort effect of scanning origin location on data accuracy of abutment teeth region in digital impression acquired using intraoral scanner for removable partial denture: a preliminary in vitro study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9783230/
https://www.ncbi.nlm.nih.gov/pubmed/36556008
http://dx.doi.org/10.3390/jcm11247392
work_keys_str_mv AT kimeungyeol effectofscanningoriginlocationondataaccuracyofabutmentteethregionindigitalimpressionacquiredusingintraoralscannerforremovablepartialdentureapreliminaryinvitrostudy
AT wadajunichiro effectofscanningoriginlocationondataaccuracyofabutmentteethregionindigitalimpressionacquiredusingintraoralscannerforremovablepartialdentureapreliminaryinvitrostudy
AT sakamotokazuki effectofscanningoriginlocationondataaccuracyofabutmentteethregionindigitalimpressionacquiredusingintraoralscannerforremovablepartialdentureapreliminaryinvitrostudy
AT ishiokayurika effectofscanningoriginlocationondataaccuracyofabutmentteethregionindigitalimpressionacquiredusingintraoralscannerforremovablepartialdentureapreliminaryinvitrostudy
AT araiyuki effectofscanningoriginlocationondataaccuracyofabutmentteethregionindigitalimpressionacquiredusingintraoralscannerforremovablepartialdentureapreliminaryinvitrostudy
AT murakaminatsuko effectofscanningoriginlocationondataaccuracyofabutmentteethregionindigitalimpressionacquiredusingintraoralscannerforremovablepartialdentureapreliminaryinvitrostudy
AT yamazakitoshiki effectofscanningoriginlocationondataaccuracyofabutmentteethregionindigitalimpressionacquiredusingintraoralscannerforremovablepartialdentureapreliminaryinvitrostudy
AT hayamahironari effectofscanningoriginlocationondataaccuracyofabutmentteethregionindigitalimpressionacquiredusingintraoralscannerforremovablepartialdentureapreliminaryinvitrostudy
AT utsumimiona effectofscanningoriginlocationondataaccuracyofabutmentteethregionindigitalimpressionacquiredusingintraoralscannerforremovablepartialdentureapreliminaryinvitrostudy
AT inukaishusuke effectofscanningoriginlocationondataaccuracyofabutmentteethregionindigitalimpressionacquiredusingintraoralscannerforremovablepartialdentureapreliminaryinvitrostudy
AT wakabayashinoriyuki effectofscanningoriginlocationondataaccuracyofabutmentteethregionindigitalimpressionacquiredusingintraoralscannerforremovablepartialdentureapreliminaryinvitrostudy