Cargando…

All-polyethylene tibia components have the same functional outcomes and survival, and are more cost-effective than metal-backed components in patients 70 years and older undergoing total knee arthroplasty: propensity match study with a minimum five-year follow-up

AIMS: The tibial component of total knee arthroplasty can either be an all-polyethylene (AP) implant or a metal-backed (MB) implant. This study aims to compare the five-year functional outcomes of AP tibial components to MB components in patients aged over 70 years. Secondary aims are to compare qua...

Descripción completa

Detalles Bibliográficos
Autores principales: Jabbal, Monu, Clement, Nick, Walmsley, Phil J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The British Editorial Society of Bone & Joint Surgery 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9783277/
https://www.ncbi.nlm.nih.gov/pubmed/36519385
http://dx.doi.org/10.1302/2633-1462.312.BJO-2022-0063.R1
_version_ 1784857540334452736
author Jabbal, Monu
Clement, Nick
Walmsley, Phil J.
author_facet Jabbal, Monu
Clement, Nick
Walmsley, Phil J.
author_sort Jabbal, Monu
collection PubMed
description AIMS: The tibial component of total knee arthroplasty can either be an all-polyethylene (AP) implant or a metal-backed (MB) implant. This study aims to compare the five-year functional outcomes of AP tibial components to MB components in patients aged over 70 years. Secondary aims are to compare quality of life, implant survivorship, and cost-effectiveness. METHODS: A group of 130 patients who had received an AP tibial component were matched for demographic factors of age, BMI, American Society of Anesthesiologists (ASA) grade, sex, and preoperative Knee Society Score (KSS) to create a comparison group of 130 patients who received a MB tibial component. Functional outcome was assessed prospectively by KSS, quality of life by 12-Item Short-Form Health Survey questionnaire (SF-12), and range of motion (ROM), and implant survivorships were compared. The SF six-dimension (6D) was used to calculate the incremental cost effectiveness ratio (ICER) for AP compared to MB tibial components using quality-adjusted life year methodology. RESULTS: The AP group had a mean KSS-Knee of 83.4 (standard deviation (SD) 19.2) and the MB group a mean of 84.9 (SD 18.2; p = 0.631), while mean KSS-Function was 75.4 (SD 15.3) and 73.2 (SD 16.2 p = 0.472), respectively. The mental (44.3 vs 45.1; p = 0.464) and physical (44.8 vs 44.9; p = 0.893) dimensions of the SF-12 and ROM (97.9° vs 99.7°; p = 0.444) were not different between the groups. Implant survivorship at five years were 99.2% and 97.7% (p = 0.321). The AP group had a greater SF-6D gain of 0.145 compared to the MB group, with an associated cost saving of £406, which resulted in a negative ICER of -£406/0.145 = -£2,800. Therefore, the AP tibial component was dominant, being a more effective and less expensive intervention. CONCLUSION: There were no differences in functional outcomes or survivorship at five years between AP and MB tibial components in patients aged 70 years and older, however the AP component was shown to be more cost-effective. In the UK, only 1.4% of all total knee arthroplasties use an AP component; even a modest increase in usage nationally could lead to significant financial savings. Cite this article: Bone Jt Open 2022;3(12):969–976.
format Online
Article
Text
id pubmed-9783277
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The British Editorial Society of Bone & Joint Surgery
record_format MEDLINE/PubMed
spelling pubmed-97832772023-01-04 All-polyethylene tibia components have the same functional outcomes and survival, and are more cost-effective than metal-backed components in patients 70 years and older undergoing total knee arthroplasty: propensity match study with a minimum five-year follow-up Jabbal, Monu Clement, Nick Walmsley, Phil J. Bone Jt Open Knee AIMS: The tibial component of total knee arthroplasty can either be an all-polyethylene (AP) implant or a metal-backed (MB) implant. This study aims to compare the five-year functional outcomes of AP tibial components to MB components in patients aged over 70 years. Secondary aims are to compare quality of life, implant survivorship, and cost-effectiveness. METHODS: A group of 130 patients who had received an AP tibial component were matched for demographic factors of age, BMI, American Society of Anesthesiologists (ASA) grade, sex, and preoperative Knee Society Score (KSS) to create a comparison group of 130 patients who received a MB tibial component. Functional outcome was assessed prospectively by KSS, quality of life by 12-Item Short-Form Health Survey questionnaire (SF-12), and range of motion (ROM), and implant survivorships were compared. The SF six-dimension (6D) was used to calculate the incremental cost effectiveness ratio (ICER) for AP compared to MB tibial components using quality-adjusted life year methodology. RESULTS: The AP group had a mean KSS-Knee of 83.4 (standard deviation (SD) 19.2) and the MB group a mean of 84.9 (SD 18.2; p = 0.631), while mean KSS-Function was 75.4 (SD 15.3) and 73.2 (SD 16.2 p = 0.472), respectively. The mental (44.3 vs 45.1; p = 0.464) and physical (44.8 vs 44.9; p = 0.893) dimensions of the SF-12 and ROM (97.9° vs 99.7°; p = 0.444) were not different between the groups. Implant survivorship at five years were 99.2% and 97.7% (p = 0.321). The AP group had a greater SF-6D gain of 0.145 compared to the MB group, with an associated cost saving of £406, which resulted in a negative ICER of -£406/0.145 = -£2,800. Therefore, the AP tibial component was dominant, being a more effective and less expensive intervention. CONCLUSION: There were no differences in functional outcomes or survivorship at five years between AP and MB tibial components in patients aged 70 years and older, however the AP component was shown to be more cost-effective. In the UK, only 1.4% of all total knee arthroplasties use an AP component; even a modest increase in usage nationally could lead to significant financial savings. Cite this article: Bone Jt Open 2022;3(12):969–976. The British Editorial Society of Bone & Joint Surgery 2022-12-16 /pmc/articles/PMC9783277/ /pubmed/36519385 http://dx.doi.org/10.1302/2633-1462.312.BJO-2022-0063.R1 Text en © 2022 Author(s) et al. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND 4.0) licence, which permits the copying and redistribution of the work only, and provided the original author and source are credited. See https://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Knee
Jabbal, Monu
Clement, Nick
Walmsley, Phil J.
All-polyethylene tibia components have the same functional outcomes and survival, and are more cost-effective than metal-backed components in patients 70 years and older undergoing total knee arthroplasty: propensity match study with a minimum five-year follow-up
title All-polyethylene tibia components have the same functional outcomes and survival, and are more cost-effective than metal-backed components in patients 70 years and older undergoing total knee arthroplasty: propensity match study with a minimum five-year follow-up
title_full All-polyethylene tibia components have the same functional outcomes and survival, and are more cost-effective than metal-backed components in patients 70 years and older undergoing total knee arthroplasty: propensity match study with a minimum five-year follow-up
title_fullStr All-polyethylene tibia components have the same functional outcomes and survival, and are more cost-effective than metal-backed components in patients 70 years and older undergoing total knee arthroplasty: propensity match study with a minimum five-year follow-up
title_full_unstemmed All-polyethylene tibia components have the same functional outcomes and survival, and are more cost-effective than metal-backed components in patients 70 years and older undergoing total knee arthroplasty: propensity match study with a minimum five-year follow-up
title_short All-polyethylene tibia components have the same functional outcomes and survival, and are more cost-effective than metal-backed components in patients 70 years and older undergoing total knee arthroplasty: propensity match study with a minimum five-year follow-up
title_sort all-polyethylene tibia components have the same functional outcomes and survival, and are more cost-effective than metal-backed components in patients 70 years and older undergoing total knee arthroplasty: propensity match study with a minimum five-year follow-up
topic Knee
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9783277/
https://www.ncbi.nlm.nih.gov/pubmed/36519385
http://dx.doi.org/10.1302/2633-1462.312.BJO-2022-0063.R1
work_keys_str_mv AT jabbalmonu allpolyethylenetibiacomponentshavethesamefunctionaloutcomesandsurvivalandaremorecosteffectivethanmetalbackedcomponentsinpatients70yearsandolderundergoingtotalkneearthroplastypropensitymatchstudywithaminimumfiveyearfollowup
AT clementnick allpolyethylenetibiacomponentshavethesamefunctionaloutcomesandsurvivalandaremorecosteffectivethanmetalbackedcomponentsinpatients70yearsandolderundergoingtotalkneearthroplastypropensitymatchstudywithaminimumfiveyearfollowup
AT walmsleyphilj allpolyethylenetibiacomponentshavethesamefunctionaloutcomesandsurvivalandaremorecosteffectivethanmetalbackedcomponentsinpatients70yearsandolderundergoingtotalkneearthroplastypropensitymatchstudywithaminimumfiveyearfollowup