Cargando…

Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates

This study aimed to address the knowledge gap in assessing the radiation doses from cone beam computed tomography (CBCT) procedures, establishing a typical value, and estimating effective and organ doses. A total of 340 patients aged 18–80 years were included in this study. Organ doses were estimate...

Descripción completa

Detalles Bibliográficos
Autores principales: Abuzaid, Mohamed M., Elshami, Wiam, Jayachandran, Deepa, Korappil, Noushad, Tekin, Huseyin O.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9783302/
https://www.ncbi.nlm.nih.gov/pubmed/36548539
http://dx.doi.org/10.3390/tomography8060247
_version_ 1784857545957965824
author Abuzaid, Mohamed M.
Elshami, Wiam
Jayachandran, Deepa
Korappil, Noushad
Tekin, Huseyin O.
author_facet Abuzaid, Mohamed M.
Elshami, Wiam
Jayachandran, Deepa
Korappil, Noushad
Tekin, Huseyin O.
author_sort Abuzaid, Mohamed M.
collection PubMed
description This study aimed to address the knowledge gap in assessing the radiation doses from cone beam computed tomography (CBCT) procedures, establishing a typical value, and estimating effective and organ doses. A total of 340 patients aged 18–80 years were included in this study. Organ doses were estimated using VirtualDose IR software. The typical values were based on median values estimated as 1000 mGy cm(2). The mean ED (µSv) per procedure was 149.5 ± 56, and the mean of the peak skin dose during the CBCT examination was 39.29 mGy. The highest organ dose was received by the salivary glands (2.71 mGy), the extrathoracic region (1.64 mGy), thyroid (1.24 mGy) and eyes (0.61 mGy). The patients’ doses were higher than in previous studies. Staff awareness, education, training and dose optimisation are highly recommended. With the establishment of local DRLs, patient dosages can be reduced successfully without compromising image quality.
format Online
Article
Text
id pubmed-9783302
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97833022022-12-24 Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates Abuzaid, Mohamed M. Elshami, Wiam Jayachandran, Deepa Korappil, Noushad Tekin, Huseyin O. Tomography Article This study aimed to address the knowledge gap in assessing the radiation doses from cone beam computed tomography (CBCT) procedures, establishing a typical value, and estimating effective and organ doses. A total of 340 patients aged 18–80 years were included in this study. Organ doses were estimated using VirtualDose IR software. The typical values were based on median values estimated as 1000 mGy cm(2). The mean ED (µSv) per procedure was 149.5 ± 56, and the mean of the peak skin dose during the CBCT examination was 39.29 mGy. The highest organ dose was received by the salivary glands (2.71 mGy), the extrathoracic region (1.64 mGy), thyroid (1.24 mGy) and eyes (0.61 mGy). The patients’ doses were higher than in previous studies. Staff awareness, education, training and dose optimisation are highly recommended. With the establishment of local DRLs, patient dosages can be reduced successfully without compromising image quality. MDPI 2022-12-14 /pmc/articles/PMC9783302/ /pubmed/36548539 http://dx.doi.org/10.3390/tomography8060247 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Abuzaid, Mohamed M.
Elshami, Wiam
Jayachandran, Deepa
Korappil, Noushad
Tekin, Huseyin O.
Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates
title Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates
title_full Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates
title_fullStr Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates
title_full_unstemmed Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates
title_short Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates
title_sort establishment of diagnostic reference levels in cone beam computed tomography scans in the united arab emirates
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9783302/
https://www.ncbi.nlm.nih.gov/pubmed/36548539
http://dx.doi.org/10.3390/tomography8060247
work_keys_str_mv AT abuzaidmohamedm establishmentofdiagnosticreferencelevelsinconebeamcomputedtomographyscansintheunitedarabemirates
AT elshamiwiam establishmentofdiagnosticreferencelevelsinconebeamcomputedtomographyscansintheunitedarabemirates
AT jayachandrandeepa establishmentofdiagnosticreferencelevelsinconebeamcomputedtomographyscansintheunitedarabemirates
AT korappilnoushad establishmentofdiagnosticreferencelevelsinconebeamcomputedtomographyscansintheunitedarabemirates
AT tekinhuseyino establishmentofdiagnosticreferencelevelsinconebeamcomputedtomographyscansintheunitedarabemirates