Cargando…
Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates
This study aimed to address the knowledge gap in assessing the radiation doses from cone beam computed tomography (CBCT) procedures, establishing a typical value, and estimating effective and organ doses. A total of 340 patients aged 18–80 years were included in this study. Organ doses were estimate...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9783302/ https://www.ncbi.nlm.nih.gov/pubmed/36548539 http://dx.doi.org/10.3390/tomography8060247 |
_version_ | 1784857545957965824 |
---|---|
author | Abuzaid, Mohamed M. Elshami, Wiam Jayachandran, Deepa Korappil, Noushad Tekin, Huseyin O. |
author_facet | Abuzaid, Mohamed M. Elshami, Wiam Jayachandran, Deepa Korappil, Noushad Tekin, Huseyin O. |
author_sort | Abuzaid, Mohamed M. |
collection | PubMed |
description | This study aimed to address the knowledge gap in assessing the radiation doses from cone beam computed tomography (CBCT) procedures, establishing a typical value, and estimating effective and organ doses. A total of 340 patients aged 18–80 years were included in this study. Organ doses were estimated using VirtualDose IR software. The typical values were based on median values estimated as 1000 mGy cm(2). The mean ED (µSv) per procedure was 149.5 ± 56, and the mean of the peak skin dose during the CBCT examination was 39.29 mGy. The highest organ dose was received by the salivary glands (2.71 mGy), the extrathoracic region (1.64 mGy), thyroid (1.24 mGy) and eyes (0.61 mGy). The patients’ doses were higher than in previous studies. Staff awareness, education, training and dose optimisation are highly recommended. With the establishment of local DRLs, patient dosages can be reduced successfully without compromising image quality. |
format | Online Article Text |
id | pubmed-9783302 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-97833022022-12-24 Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates Abuzaid, Mohamed M. Elshami, Wiam Jayachandran, Deepa Korappil, Noushad Tekin, Huseyin O. Tomography Article This study aimed to address the knowledge gap in assessing the radiation doses from cone beam computed tomography (CBCT) procedures, establishing a typical value, and estimating effective and organ doses. A total of 340 patients aged 18–80 years were included in this study. Organ doses were estimated using VirtualDose IR software. The typical values were based on median values estimated as 1000 mGy cm(2). The mean ED (µSv) per procedure was 149.5 ± 56, and the mean of the peak skin dose during the CBCT examination was 39.29 mGy. The highest organ dose was received by the salivary glands (2.71 mGy), the extrathoracic region (1.64 mGy), thyroid (1.24 mGy) and eyes (0.61 mGy). The patients’ doses were higher than in previous studies. Staff awareness, education, training and dose optimisation are highly recommended. With the establishment of local DRLs, patient dosages can be reduced successfully without compromising image quality. MDPI 2022-12-14 /pmc/articles/PMC9783302/ /pubmed/36548539 http://dx.doi.org/10.3390/tomography8060247 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Abuzaid, Mohamed M. Elshami, Wiam Jayachandran, Deepa Korappil, Noushad Tekin, Huseyin O. Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates |
title | Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates |
title_full | Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates |
title_fullStr | Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates |
title_full_unstemmed | Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates |
title_short | Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates |
title_sort | establishment of diagnostic reference levels in cone beam computed tomography scans in the united arab emirates |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9783302/ https://www.ncbi.nlm.nih.gov/pubmed/36548539 http://dx.doi.org/10.3390/tomography8060247 |
work_keys_str_mv | AT abuzaidmohamedm establishmentofdiagnosticreferencelevelsinconebeamcomputedtomographyscansintheunitedarabemirates AT elshamiwiam establishmentofdiagnosticreferencelevelsinconebeamcomputedtomographyscansintheunitedarabemirates AT jayachandrandeepa establishmentofdiagnosticreferencelevelsinconebeamcomputedtomographyscansintheunitedarabemirates AT korappilnoushad establishmentofdiagnosticreferencelevelsinconebeamcomputedtomographyscansintheunitedarabemirates AT tekinhuseyino establishmentofdiagnosticreferencelevelsinconebeamcomputedtomographyscansintheunitedarabemirates |