Cargando…

Effect of high-flow oxygen versus T-piece ventilation strategies during spontaneous breathing trials on weaning failure among patients receiving mechanical ventilation: a randomized controlled trial

BACKGROUND: A spontaneous breathing trial (SBT) is used to determine whether patients are ready for extubation, but the best method for choosing the SBT strategy remains controversial. We investigated the effect of high-flow oxygen versus T-piece ventilation strategies during SBT on rates of weaning...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Hong Yeul, Lee, Jinwoo, Lee, Sang-Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9783722/
https://www.ncbi.nlm.nih.gov/pubmed/36564808
http://dx.doi.org/10.1186/s13054-022-04281-w
Descripción
Sumario:BACKGROUND: A spontaneous breathing trial (SBT) is used to determine whether patients are ready for extubation, but the best method for choosing the SBT strategy remains controversial. We investigated the effect of high-flow oxygen versus T-piece ventilation strategies during SBT on rates of weaning failure among patients receiving mechanical ventilation. METHODS: This randomized clinical trial was conducted from June 2019 through January 2022 among patients receiving mechanical ventilation for ≥ 12 h who fulfilled the weaning readiness criteria at a single-center medical intensive care unit. Patients were randomized to undergo either T-piece SBT or high-flow oxygen SBT. The primary outcome was weaning failure on day 2, and the secondary outcomes were weaning failure on day 7, ICU and hospital length of stay, and ICU and in-hospital morality. RESULTS: Of 108 patients (mean age, 67.0 ± 11.1 years; 64.8% men), 54 received T-piece SBT and 54 received high-flow oxygen SBT. Weaning failure on day 2 occurred in 5 patients (9.3%) in the T-piece group and 3 patients (5.6%) in the high-flow group (difference, 3.7% [95% CI, − 6.1–13.6]; p = 0.713). Weaning failure on day 7 occurred in 13 patients (24.1%) in the T-piece group and 7 patients (13.0%) in the high-flow group (difference, 11.1% [95% CI, − 3.4–25.6]; p = 0.215). A post hoc subgroup analysis showed that high-flow oxygen SBT was significantly associated with a lower rate of weaning failure on day 7 (OR, 0.17 [95% CI, 0.04–0.78]) among those patients intubated because of respiratory failure (p for interaction = 0.020). The ICU and hospital length of stay and mortality rates did not differ significantly between the two groups. During the study, no serious adverse events were recorded. CONCLUSIONS: Among patients receiving mechanical ventilation, high-flow oxygen SBT did not significantly reduce the risk of weaning failure compared with T-piece SBT. However, the study may have been underpowered to detect a clinically important treatment effect for the comparison of high-flow oxygen SBT versus T-piece SBT, and a higher percentage of patients with simple weaning and a lower weaning failure rate than expected should be considered when interpreting the findings. Clinical trial registration This trial was registered with ClinicalTrials.gov (number NCT03929328) on April 26, 2019. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13054-022-04281-w.