Cargando…

Experimental Performance of a Membrane Desorber with a H(2)O/LiCl Mixture for Absorption Chiller Applications

For absorption cooling cycles using water as a refrigerant, H(2)O/LiCl mixtures are suitable for replacing conventional H(2)O/LiBr mixtures. In addition, membrane devices can be used to develop compact and lighter absorption systems, and they can operate with H(2)O/LiCl mixtures. The present paper d...

Descripción completa

Detalles Bibliográficos
Autores principales: Ibarra-Bahena, Jonathan, Dehesa-Carrasco, Ulises, Galindo-Luna, Yuridiana Rocio, Medina-Caballero, Iván Leonardo, Rivera, Wilfrido
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9784068/
https://www.ncbi.nlm.nih.gov/pubmed/36557089
http://dx.doi.org/10.3390/membranes12121184
_version_ 1784857722980663296
author Ibarra-Bahena, Jonathan
Dehesa-Carrasco, Ulises
Galindo-Luna, Yuridiana Rocio
Medina-Caballero, Iván Leonardo
Rivera, Wilfrido
author_facet Ibarra-Bahena, Jonathan
Dehesa-Carrasco, Ulises
Galindo-Luna, Yuridiana Rocio
Medina-Caballero, Iván Leonardo
Rivera, Wilfrido
author_sort Ibarra-Bahena, Jonathan
collection PubMed
description For absorption cooling cycles using water as a refrigerant, H(2)O/LiCl mixtures are suitable for replacing conventional H(2)O/LiBr mixtures. In addition, membrane devices can be used to develop compact and lighter absorption systems, and they can operate with H(2)O/LiCl mixtures. The present paper describes an experimental evaluation of a membrane desorber/condenser operating at atmospheric pressure. Two operation modes were analyzed: continuous cycle operation and intermittent operation. For the first operation mode, the maximum desorption rate was 3.49 kg/h·m(2), with a solution temperature of 90.3 °C and a condensation temperature of 25.1 °C. The lowest desorption rate value was 0.26 kg/h·m(2), with a solution temperature of 75.4 °C and a condensation temperature of 40.1 °C. In the second mode, after three operating hours, the refrigerant fluid produced, per 1 m(2) of membrane area, 7.7, 5.6, 4.3, and 2.2 kg, at solution temperatures of 90.3, 85.3, 80.4, and 75.4 °C, respectively. A one-dimension heat and mass transfer model is presented. The calculated values of desorption rate and outlet temperatures were compared with the experimental data; a square correlation coefficient of 0.9929 was reached for the desorption rate; meanwhile, for the outlet solution temperatures and the outlet cooling-water temperatures, a square correlation coefficient up to 0.9991 was achieved. The membrane desorber has the advantages of operating at atmospheric-pressure conditions, high condensation temperature, the ability to use different saline solution working mixtures, and different operation methods. These advantages can lead to new absorption systems.
format Online
Article
Text
id pubmed-9784068
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97840682022-12-24 Experimental Performance of a Membrane Desorber with a H(2)O/LiCl Mixture for Absorption Chiller Applications Ibarra-Bahena, Jonathan Dehesa-Carrasco, Ulises Galindo-Luna, Yuridiana Rocio Medina-Caballero, Iván Leonardo Rivera, Wilfrido Membranes (Basel) Article For absorption cooling cycles using water as a refrigerant, H(2)O/LiCl mixtures are suitable for replacing conventional H(2)O/LiBr mixtures. In addition, membrane devices can be used to develop compact and lighter absorption systems, and they can operate with H(2)O/LiCl mixtures. The present paper describes an experimental evaluation of a membrane desorber/condenser operating at atmospheric pressure. Two operation modes were analyzed: continuous cycle operation and intermittent operation. For the first operation mode, the maximum desorption rate was 3.49 kg/h·m(2), with a solution temperature of 90.3 °C and a condensation temperature of 25.1 °C. The lowest desorption rate value was 0.26 kg/h·m(2), with a solution temperature of 75.4 °C and a condensation temperature of 40.1 °C. In the second mode, after three operating hours, the refrigerant fluid produced, per 1 m(2) of membrane area, 7.7, 5.6, 4.3, and 2.2 kg, at solution temperatures of 90.3, 85.3, 80.4, and 75.4 °C, respectively. A one-dimension heat and mass transfer model is presented. The calculated values of desorption rate and outlet temperatures were compared with the experimental data; a square correlation coefficient of 0.9929 was reached for the desorption rate; meanwhile, for the outlet solution temperatures and the outlet cooling-water temperatures, a square correlation coefficient up to 0.9991 was achieved. The membrane desorber has the advantages of operating at atmospheric-pressure conditions, high condensation temperature, the ability to use different saline solution working mixtures, and different operation methods. These advantages can lead to new absorption systems. MDPI 2022-11-24 /pmc/articles/PMC9784068/ /pubmed/36557089 http://dx.doi.org/10.3390/membranes12121184 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ibarra-Bahena, Jonathan
Dehesa-Carrasco, Ulises
Galindo-Luna, Yuridiana Rocio
Medina-Caballero, Iván Leonardo
Rivera, Wilfrido
Experimental Performance of a Membrane Desorber with a H(2)O/LiCl Mixture for Absorption Chiller Applications
title Experimental Performance of a Membrane Desorber with a H(2)O/LiCl Mixture for Absorption Chiller Applications
title_full Experimental Performance of a Membrane Desorber with a H(2)O/LiCl Mixture for Absorption Chiller Applications
title_fullStr Experimental Performance of a Membrane Desorber with a H(2)O/LiCl Mixture for Absorption Chiller Applications
title_full_unstemmed Experimental Performance of a Membrane Desorber with a H(2)O/LiCl Mixture for Absorption Chiller Applications
title_short Experimental Performance of a Membrane Desorber with a H(2)O/LiCl Mixture for Absorption Chiller Applications
title_sort experimental performance of a membrane desorber with a h(2)o/licl mixture for absorption chiller applications
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9784068/
https://www.ncbi.nlm.nih.gov/pubmed/36557089
http://dx.doi.org/10.3390/membranes12121184
work_keys_str_mv AT ibarrabahenajonathan experimentalperformanceofamembranedesorberwithah2oliclmixtureforabsorptionchillerapplications
AT dehesacarrascoulises experimentalperformanceofamembranedesorberwithah2oliclmixtureforabsorptionchillerapplications
AT galindolunayuridianarocio experimentalperformanceofamembranedesorberwithah2oliclmixtureforabsorptionchillerapplications
AT medinacaballeroivanleonardo experimentalperformanceofamembranedesorberwithah2oliclmixtureforabsorptionchillerapplications
AT riverawilfrido experimentalperformanceofamembranedesorberwithah2oliclmixtureforabsorptionchillerapplications