Cargando…
High-Aperture-Ratio Dual-View Integral Imaging Display
Low aperture ratio is a problem in the conventional dual-view integral imaging (DVII) display using a point light source array. A high-aperture-ratio DVII display using a gradient width point light source array is reported in this work. The elemental Images 1 and 2, which are alternatively aligned o...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9785181/ https://www.ncbi.nlm.nih.gov/pubmed/36557512 http://dx.doi.org/10.3390/mi13122213 |
_version_ | 1784857986533949440 |
---|---|
author | Zhao, Bai-Chuan Yang, Fan Wu, Fei |
author_facet | Zhao, Bai-Chuan Yang, Fan Wu, Fei |
author_sort | Zhao, Bai-Chuan |
collection | PubMed |
description | Low aperture ratio is a problem in the conventional dual-view integral imaging (DVII) display using a point light source array. A high-aperture-ratio DVII display using a gradient width point light source array is reported in this work. The elemental Images 1 and 2, which are alternatively aligned on a liquid crystal panel, are illuminated by the light rays emitted from an assigned point light source. The optical path is optimized by optimizing the widths of the point light sources. The aperture ratio of the proposed DVII display was demonstrated as 1.88 times the conventional DVII display. Experiments showed that the vertical viewing range is related to the vertical width of the first row point light source, whereas the aperture ratio is related to the vertical widths of all point light sources. By optimizing the widths of the point light sources, the aperture ratio is enhanced without loss of viewing range. |
format | Online Article Text |
id | pubmed-9785181 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-97851812022-12-24 High-Aperture-Ratio Dual-View Integral Imaging Display Zhao, Bai-Chuan Yang, Fan Wu, Fei Micromachines (Basel) Article Low aperture ratio is a problem in the conventional dual-view integral imaging (DVII) display using a point light source array. A high-aperture-ratio DVII display using a gradient width point light source array is reported in this work. The elemental Images 1 and 2, which are alternatively aligned on a liquid crystal panel, are illuminated by the light rays emitted from an assigned point light source. The optical path is optimized by optimizing the widths of the point light sources. The aperture ratio of the proposed DVII display was demonstrated as 1.88 times the conventional DVII display. Experiments showed that the vertical viewing range is related to the vertical width of the first row point light source, whereas the aperture ratio is related to the vertical widths of all point light sources. By optimizing the widths of the point light sources, the aperture ratio is enhanced without loss of viewing range. MDPI 2022-12-14 /pmc/articles/PMC9785181/ /pubmed/36557512 http://dx.doi.org/10.3390/mi13122213 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhao, Bai-Chuan Yang, Fan Wu, Fei High-Aperture-Ratio Dual-View Integral Imaging Display |
title | High-Aperture-Ratio Dual-View Integral Imaging Display |
title_full | High-Aperture-Ratio Dual-View Integral Imaging Display |
title_fullStr | High-Aperture-Ratio Dual-View Integral Imaging Display |
title_full_unstemmed | High-Aperture-Ratio Dual-View Integral Imaging Display |
title_short | High-Aperture-Ratio Dual-View Integral Imaging Display |
title_sort | high-aperture-ratio dual-view integral imaging display |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9785181/ https://www.ncbi.nlm.nih.gov/pubmed/36557512 http://dx.doi.org/10.3390/mi13122213 |
work_keys_str_mv | AT zhaobaichuan highapertureratiodualviewintegralimagingdisplay AT yangfan highapertureratiodualviewintegralimagingdisplay AT wufei highapertureratiodualviewintegralimagingdisplay |