Cargando…

Bioburden Variation of Filtering Face Piece Respirators over Time: A Preliminary Study

Background: The microbial contamination of a respirator can be evaluated through a count of the number of bacteria living on a non-sterilized surface (bioburden). This preliminary study investigated the external contamination of two different FFP2s over time by studying the bioburden values in incre...

Descripción completa

Detalles Bibliográficos
Autores principales: Checchi, Vittorio, Montevecchi, Marco, Valeriani, Leoluca, Checchi, Luigi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9785761/
https://www.ncbi.nlm.nih.gov/pubmed/36556594
http://dx.doi.org/10.3390/ma15248790
_version_ 1784858127442640896
author Checchi, Vittorio
Montevecchi, Marco
Valeriani, Leoluca
Checchi, Luigi
author_facet Checchi, Vittorio
Montevecchi, Marco
Valeriani, Leoluca
Checchi, Luigi
author_sort Checchi, Vittorio
collection PubMed
description Background: The microbial contamination of a respirator can be evaluated through a count of the number of bacteria living on a non-sterilized surface (bioburden). This preliminary study investigated the external contamination of two different FFP2s over time by studying the bioburden values in increasing exposure times. Methods: FFP2 respirators of two different brands were used during routine clinical settings and examined through the bioburden test; for each brand, three devices were tested at 8, 16, and 30 h. Results: No significant differences were observed between mask brands (p = 0.113). There were only significant CFU differences between each mask and its control (p = 0.027 and p = 0.004). Conclusions: Both brands of respirators were found to be contaminated and this contamination increased with the increase in exposure time. Further studies are needed to investigate the exact amount of contamination that could be considered acceptable before discarding each used mask.
format Online
Article
Text
id pubmed-9785761
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97857612022-12-24 Bioburden Variation of Filtering Face Piece Respirators over Time: A Preliminary Study Checchi, Vittorio Montevecchi, Marco Valeriani, Leoluca Checchi, Luigi Materials (Basel) Article Background: The microbial contamination of a respirator can be evaluated through a count of the number of bacteria living on a non-sterilized surface (bioburden). This preliminary study investigated the external contamination of two different FFP2s over time by studying the bioburden values in increasing exposure times. Methods: FFP2 respirators of two different brands were used during routine clinical settings and examined through the bioburden test; for each brand, three devices were tested at 8, 16, and 30 h. Results: No significant differences were observed between mask brands (p = 0.113). There were only significant CFU differences between each mask and its control (p = 0.027 and p = 0.004). Conclusions: Both brands of respirators were found to be contaminated and this contamination increased with the increase in exposure time. Further studies are needed to investigate the exact amount of contamination that could be considered acceptable before discarding each used mask. MDPI 2022-12-09 /pmc/articles/PMC9785761/ /pubmed/36556594 http://dx.doi.org/10.3390/ma15248790 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Checchi, Vittorio
Montevecchi, Marco
Valeriani, Leoluca
Checchi, Luigi
Bioburden Variation of Filtering Face Piece Respirators over Time: A Preliminary Study
title Bioburden Variation of Filtering Face Piece Respirators over Time: A Preliminary Study
title_full Bioburden Variation of Filtering Face Piece Respirators over Time: A Preliminary Study
title_fullStr Bioburden Variation of Filtering Face Piece Respirators over Time: A Preliminary Study
title_full_unstemmed Bioburden Variation of Filtering Face Piece Respirators over Time: A Preliminary Study
title_short Bioburden Variation of Filtering Face Piece Respirators over Time: A Preliminary Study
title_sort bioburden variation of filtering face piece respirators over time: a preliminary study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9785761/
https://www.ncbi.nlm.nih.gov/pubmed/36556594
http://dx.doi.org/10.3390/ma15248790
work_keys_str_mv AT checchivittorio bioburdenvariationoffilteringfacepiecerespiratorsovertimeapreliminarystudy
AT montevecchimarco bioburdenvariationoffilteringfacepiecerespiratorsovertimeapreliminarystudy
AT valerianileoluca bioburdenvariationoffilteringfacepiecerespiratorsovertimeapreliminarystudy
AT checchiluigi bioburdenvariationoffilteringfacepiecerespiratorsovertimeapreliminarystudy