Cargando…

Robotic single port anti‐reflux surgery: Initial worldwide experience of two cases with a novel surgical approach to treat gastroesophageal reflux disease

INTRODUCTION: To date, no anti‐reflux operations have been reported with the new da Vinci Single‐Port (single port (SP)) robotic platform. We aimed to describe this novel surgical approach and evaluate its safety and feasibility. METHODS: All robotic SP operations were performed under an Institution...

Descripción completa

Detalles Bibliográficos
Autores principales: Cubisino, Antonio, Dreifuss, Nicolas H., Schlottmann, Francisco, Baz, Carolina, Mangano, Alberto, Masrur, Mario A., Bianco, Francesco M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9786780/
https://www.ncbi.nlm.nih.gov/pubmed/35754403
http://dx.doi.org/10.1002/rcs.2437
_version_ 1784858368716832768
author Cubisino, Antonio
Dreifuss, Nicolas H.
Schlottmann, Francisco
Baz, Carolina
Mangano, Alberto
Masrur, Mario A.
Bianco, Francesco M.
author_facet Cubisino, Antonio
Dreifuss, Nicolas H.
Schlottmann, Francisco
Baz, Carolina
Mangano, Alberto
Masrur, Mario A.
Bianco, Francesco M.
author_sort Cubisino, Antonio
collection PubMed
description INTRODUCTION: To date, no anti‐reflux operations have been reported with the new da Vinci Single‐Port (single port (SP)) robotic platform. We aimed to describe this novel surgical approach and evaluate its safety and feasibility. METHODS: All robotic SP operations were performed under an Institutional Review Board approved protocol. RESULTS: Two patients underwent robotic SP anti‐reflux surgery through a single incision of 2.7 cm (one Nissen‐fundoplication and one re‐Redo Nissen‐fundoplication). The mean docking‐time was 2.5 (2–3) minutes and mean console‐time was 147 (119–155) minutes. No additional ports were needed, and no intraoperative complications occurred. Patients tolerated a soft diet on postoperative day 1 and were discharged on POD‐2 and 3. CONCLUSION: Robotic SP anti‐reflux surgery appears to be safe and feasible. This platform offers similar advantages to the multiport robotic surgery, while adding lower invasiveness and an improved cosmesis. Further studies are needed to confirm our results and evaluate long‐term outcomes of this surgical approach.
format Online
Article
Text
id pubmed-9786780
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-97867802022-12-27 Robotic single port anti‐reflux surgery: Initial worldwide experience of two cases with a novel surgical approach to treat gastroesophageal reflux disease Cubisino, Antonio Dreifuss, Nicolas H. Schlottmann, Francisco Baz, Carolina Mangano, Alberto Masrur, Mario A. Bianco, Francesco M. Int J Med Robot Original Articles INTRODUCTION: To date, no anti‐reflux operations have been reported with the new da Vinci Single‐Port (single port (SP)) robotic platform. We aimed to describe this novel surgical approach and evaluate its safety and feasibility. METHODS: All robotic SP operations were performed under an Institutional Review Board approved protocol. RESULTS: Two patients underwent robotic SP anti‐reflux surgery through a single incision of 2.7 cm (one Nissen‐fundoplication and one re‐Redo Nissen‐fundoplication). The mean docking‐time was 2.5 (2–3) minutes and mean console‐time was 147 (119–155) minutes. No additional ports were needed, and no intraoperative complications occurred. Patients tolerated a soft diet on postoperative day 1 and were discharged on POD‐2 and 3. CONCLUSION: Robotic SP anti‐reflux surgery appears to be safe and feasible. This platform offers similar advantages to the multiport robotic surgery, while adding lower invasiveness and an improved cosmesis. Further studies are needed to confirm our results and evaluate long‐term outcomes of this surgical approach. John Wiley and Sons Inc. 2022-09-05 2022-12 /pmc/articles/PMC9786780/ /pubmed/35754403 http://dx.doi.org/10.1002/rcs.2437 Text en © 2022 The Authors. The International Journal of Medical Robotics and Computer Assisted Surgery published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Articles
Cubisino, Antonio
Dreifuss, Nicolas H.
Schlottmann, Francisco
Baz, Carolina
Mangano, Alberto
Masrur, Mario A.
Bianco, Francesco M.
Robotic single port anti‐reflux surgery: Initial worldwide experience of two cases with a novel surgical approach to treat gastroesophageal reflux disease
title Robotic single port anti‐reflux surgery: Initial worldwide experience of two cases with a novel surgical approach to treat gastroesophageal reflux disease
title_full Robotic single port anti‐reflux surgery: Initial worldwide experience of two cases with a novel surgical approach to treat gastroesophageal reflux disease
title_fullStr Robotic single port anti‐reflux surgery: Initial worldwide experience of two cases with a novel surgical approach to treat gastroesophageal reflux disease
title_full_unstemmed Robotic single port anti‐reflux surgery: Initial worldwide experience of two cases with a novel surgical approach to treat gastroesophageal reflux disease
title_short Robotic single port anti‐reflux surgery: Initial worldwide experience of two cases with a novel surgical approach to treat gastroesophageal reflux disease
title_sort robotic single port anti‐reflux surgery: initial worldwide experience of two cases with a novel surgical approach to treat gastroesophageal reflux disease
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9786780/
https://www.ncbi.nlm.nih.gov/pubmed/35754403
http://dx.doi.org/10.1002/rcs.2437
work_keys_str_mv AT cubisinoantonio roboticsingleportantirefluxsurgeryinitialworldwideexperienceoftwocaseswithanovelsurgicalapproachtotreatgastroesophagealrefluxdisease
AT dreifussnicolash roboticsingleportantirefluxsurgeryinitialworldwideexperienceoftwocaseswithanovelsurgicalapproachtotreatgastroesophagealrefluxdisease
AT schlottmannfrancisco roboticsingleportantirefluxsurgeryinitialworldwideexperienceoftwocaseswithanovelsurgicalapproachtotreatgastroesophagealrefluxdisease
AT bazcarolina roboticsingleportantirefluxsurgeryinitialworldwideexperienceoftwocaseswithanovelsurgicalapproachtotreatgastroesophagealrefluxdisease
AT manganoalberto roboticsingleportantirefluxsurgeryinitialworldwideexperienceoftwocaseswithanovelsurgicalapproachtotreatgastroesophagealrefluxdisease
AT masrurmarioa roboticsingleportantirefluxsurgeryinitialworldwideexperienceoftwocaseswithanovelsurgicalapproachtotreatgastroesophagealrefluxdisease
AT biancofrancescom roboticsingleportantirefluxsurgeryinitialworldwideexperienceoftwocaseswithanovelsurgicalapproachtotreatgastroesophagealrefluxdisease