Cargando…

Generalized Scale Factor Calibration Method for an Off-Axis Digital Image Correlation-Based Video Deflectometer

When using off-axis digital image correlation (DIC) for non-contact, remote, and multipoint deflection monitoring of engineering structures, accurate calibration of the scale factor (SF), which converts image displacement to physical displacement for each measurement point, is critical to realize hi...

Descripción completa

Detalles Bibliográficos
Autores principales: Tian, Long, Ding, Tong, Pan, Bing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9788336/
https://www.ncbi.nlm.nih.gov/pubmed/36560378
http://dx.doi.org/10.3390/s222410010
_version_ 1784858729742598144
author Tian, Long
Ding, Tong
Pan, Bing
author_facet Tian, Long
Ding, Tong
Pan, Bing
author_sort Tian, Long
collection PubMed
description When using off-axis digital image correlation (DIC) for non-contact, remote, and multipoint deflection monitoring of engineering structures, accurate calibration of the scale factor (SF), which converts image displacement to physical displacement for each measurement point, is critical to realize high-quality displacement measurement. In this work, based on the distortion-free pinhole imaging model, a generalized SF calibration model is proposed for an off-axis DIC-based video deflectometer. Then, the transversal relationship between the proposed SF calibration method and three commonly used SF calibration methods was discussed. The accuracy of these SF calibration methods was also compared using indoor rigid body translation experiments. It is proved that the proposed method can be degraded to one of the existing calibration methods in most cases, but will provide more accurate results under the following four conditions: (1) the camera’s pitch angle is more than 20°, (2) the focal length is more than 25 mm, (3) the pixel size of the camera sensor is more than 5 um, and (4) the image y-coordinate corresponding to the measurement point after deformation is far from the image center.
format Online
Article
Text
id pubmed-9788336
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97883362022-12-24 Generalized Scale Factor Calibration Method for an Off-Axis Digital Image Correlation-Based Video Deflectometer Tian, Long Ding, Tong Pan, Bing Sensors (Basel) Article When using off-axis digital image correlation (DIC) for non-contact, remote, and multipoint deflection monitoring of engineering structures, accurate calibration of the scale factor (SF), which converts image displacement to physical displacement for each measurement point, is critical to realize high-quality displacement measurement. In this work, based on the distortion-free pinhole imaging model, a generalized SF calibration model is proposed for an off-axis DIC-based video deflectometer. Then, the transversal relationship between the proposed SF calibration method and three commonly used SF calibration methods was discussed. The accuracy of these SF calibration methods was also compared using indoor rigid body translation experiments. It is proved that the proposed method can be degraded to one of the existing calibration methods in most cases, but will provide more accurate results under the following four conditions: (1) the camera’s pitch angle is more than 20°, (2) the focal length is more than 25 mm, (3) the pixel size of the camera sensor is more than 5 um, and (4) the image y-coordinate corresponding to the measurement point after deformation is far from the image center. MDPI 2022-12-19 /pmc/articles/PMC9788336/ /pubmed/36560378 http://dx.doi.org/10.3390/s222410010 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Tian, Long
Ding, Tong
Pan, Bing
Generalized Scale Factor Calibration Method for an Off-Axis Digital Image Correlation-Based Video Deflectometer
title Generalized Scale Factor Calibration Method for an Off-Axis Digital Image Correlation-Based Video Deflectometer
title_full Generalized Scale Factor Calibration Method for an Off-Axis Digital Image Correlation-Based Video Deflectometer
title_fullStr Generalized Scale Factor Calibration Method for an Off-Axis Digital Image Correlation-Based Video Deflectometer
title_full_unstemmed Generalized Scale Factor Calibration Method for an Off-Axis Digital Image Correlation-Based Video Deflectometer
title_short Generalized Scale Factor Calibration Method for an Off-Axis Digital Image Correlation-Based Video Deflectometer
title_sort generalized scale factor calibration method for an off-axis digital image correlation-based video deflectometer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9788336/
https://www.ncbi.nlm.nih.gov/pubmed/36560378
http://dx.doi.org/10.3390/s222410010
work_keys_str_mv AT tianlong generalizedscalefactorcalibrationmethodforanoffaxisdigitalimagecorrelationbasedvideodeflectometer
AT dingtong generalizedscalefactorcalibrationmethodforanoffaxisdigitalimagecorrelationbasedvideodeflectometer
AT panbing generalizedscalefactorcalibrationmethodforanoffaxisdigitalimagecorrelationbasedvideodeflectometer