Impact of Temporal Resolution and Methods for Correction on Cardiac Magnetic Resonance Perfusion Quantification

BACKGROUND: Acquisition of magnetic resonance first‐pass perfusion images is synchronized to the patient's heart rate (HR) and governs the temporal resolution. This is inherently linked to the process of myocardial blood flow (MBF) quantification and impacts MBF accuracy but to an unclear exten...

Descripción completa

Detalles Bibliográficos
Autores principales: Milidonis, Xenios, Nazir, Muhummad Sohaib, Chiribiri, Amedeo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9790572/
https://www.ncbi.nlm.nih.gov/pubmed/35338754
http://dx.doi.org/10.1002/jmri.28180
_version_ 1784859208509816832
author Milidonis, Xenios
Nazir, Muhummad Sohaib
Chiribiri, Amedeo
author_facet Milidonis, Xenios
Nazir, Muhummad Sohaib
Chiribiri, Amedeo
author_sort Milidonis, Xenios
collection PubMed
description BACKGROUND: Acquisition of magnetic resonance first‐pass perfusion images is synchronized to the patient's heart rate (HR) and governs the temporal resolution. This is inherently linked to the process of myocardial blood flow (MBF) quantification and impacts MBF accuracy but to an unclear extent. PURPOSE: To assess the impact of temporal resolution on quantitative perfusion and compare approaches for accounting for its variability. STUDY TYPE: Prospective phantom and retrospective clinical study. POPULATION AND PHANTOM: Simulations, a cardiac perfusion phantom, and 30 patients with (16, 53%) or without (14, 47%) coronary artery disease. FIELD STRENGTH/SEQUENCE: 3.0 T/2D saturation recovery spoiled gradient echo sequence. ASSESSMENT: Dynamic perfusion data were simulated for a range of reference MBF (1 mL/g/min–5 mL/g/min) and HR (30 bpm–150 bpm). Perfusion imaging was performed in patients and a phantom for different temporal resolutions. MBF and myocardial perfusion reserve (MPR) were quantified without correction for temporal resolution or following correction by either MBF scaling based on the sampling interval or data interpolation prior to quantification. Simulated data were quantified using Fermi deconvolution, truncated singular value decomposition, and one‐compartment modeling, whereas phantom and clinical data were quantified using Fermi deconvolution alone. STATISTICAL TESTS: Shapiro–Wilk tests for normality, percentage error (PE) for measuring MBF accuracy in simulations, and one‐way repeated measures analysis of variance with Bonferroni correction to compare clinical MBF and MPR. Statistical significance set at P < 0.05. RESULTS: For Fermi deconvolution and an example simulated 1 mL/g/min, the MBF PE without correction for temporal resolution was between 55.4% and −62.7% across 30–150 bpm. PE was between −22.2% and −6.8% following MBF scaling and between −14.2% and −14.2% following data interpolation across the same HR. An interpolated HR of 240 bpm reduced PE to ≤10%. Clinical rest and stress MBF and MPR were significantly different between analyses. DATA CONCLUSION: Accurate perfusion quantification needs to account for the variability of temporal resolution, with data interpolation prior to quantification reducing MBF variability across different resolutions. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 1
format Online
Article
Text
id pubmed-9790572
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-97905722022-12-28 Impact of Temporal Resolution and Methods for Correction on Cardiac Magnetic Resonance Perfusion Quantification Milidonis, Xenios Nazir, Muhummad Sohaib Chiribiri, Amedeo J Magn Reson Imaging Research Articles BACKGROUND: Acquisition of magnetic resonance first‐pass perfusion images is synchronized to the patient's heart rate (HR) and governs the temporal resolution. This is inherently linked to the process of myocardial blood flow (MBF) quantification and impacts MBF accuracy but to an unclear extent. PURPOSE: To assess the impact of temporal resolution on quantitative perfusion and compare approaches for accounting for its variability. STUDY TYPE: Prospective phantom and retrospective clinical study. POPULATION AND PHANTOM: Simulations, a cardiac perfusion phantom, and 30 patients with (16, 53%) or without (14, 47%) coronary artery disease. FIELD STRENGTH/SEQUENCE: 3.0 T/2D saturation recovery spoiled gradient echo sequence. ASSESSMENT: Dynamic perfusion data were simulated for a range of reference MBF (1 mL/g/min–5 mL/g/min) and HR (30 bpm–150 bpm). Perfusion imaging was performed in patients and a phantom for different temporal resolutions. MBF and myocardial perfusion reserve (MPR) were quantified without correction for temporal resolution or following correction by either MBF scaling based on the sampling interval or data interpolation prior to quantification. Simulated data were quantified using Fermi deconvolution, truncated singular value decomposition, and one‐compartment modeling, whereas phantom and clinical data were quantified using Fermi deconvolution alone. STATISTICAL TESTS: Shapiro–Wilk tests for normality, percentage error (PE) for measuring MBF accuracy in simulations, and one‐way repeated measures analysis of variance with Bonferroni correction to compare clinical MBF and MPR. Statistical significance set at P < 0.05. RESULTS: For Fermi deconvolution and an example simulated 1 mL/g/min, the MBF PE without correction for temporal resolution was between 55.4% and −62.7% across 30–150 bpm. PE was between −22.2% and −6.8% following MBF scaling and between −14.2% and −14.2% following data interpolation across the same HR. An interpolated HR of 240 bpm reduced PE to ≤10%. Clinical rest and stress MBF and MPR were significantly different between analyses. DATA CONCLUSION: Accurate perfusion quantification needs to account for the variability of temporal resolution, with data interpolation prior to quantification reducing MBF variability across different resolutions. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 1 John Wiley & Sons, Inc. 2022-03-26 2022-12 /pmc/articles/PMC9790572/ /pubmed/35338754 http://dx.doi.org/10.1002/jmri.28180 Text en © 2022 The Authors. Journal of Magnetic Resonance Imaging published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Milidonis, Xenios
Nazir, Muhummad Sohaib
Chiribiri, Amedeo
Impact of Temporal Resolution and Methods for Correction on Cardiac Magnetic Resonance Perfusion Quantification
title Impact of Temporal Resolution and Methods for Correction on Cardiac Magnetic Resonance Perfusion Quantification
title_full Impact of Temporal Resolution and Methods for Correction on Cardiac Magnetic Resonance Perfusion Quantification
title_fullStr Impact of Temporal Resolution and Methods for Correction on Cardiac Magnetic Resonance Perfusion Quantification
title_full_unstemmed Impact of Temporal Resolution and Methods for Correction on Cardiac Magnetic Resonance Perfusion Quantification
title_short Impact of Temporal Resolution and Methods for Correction on Cardiac Magnetic Resonance Perfusion Quantification
title_sort impact of temporal resolution and methods for correction on cardiac magnetic resonance perfusion quantification
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9790572/
https://www.ncbi.nlm.nih.gov/pubmed/35338754
http://dx.doi.org/10.1002/jmri.28180
work_keys_str_mv AT milidonisxenios impactoftemporalresolutionandmethodsforcorrectiononcardiacmagneticresonanceperfusionquantification
AT nazirmuhummadsohaib impactoftemporalresolutionandmethodsforcorrectiononcardiacmagneticresonanceperfusionquantification
AT chiribiriamedeo impactoftemporalresolutionandmethodsforcorrectiononcardiacmagneticresonanceperfusionquantification