Cargando…
Accuracy of cytological examination of Tao brush endometrial sampling in diagnosing endometrial premalignancy and malignancy
Although Tao brush has become one of the most studied and used endometrial cytological samplers, concerns remain about the adequacy of the cytological sample compared with definitive histology. We aimed to assess accuracy of cytological examination from Tao brush sampling in diagnosing endometrial p...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9790584/ https://www.ncbi.nlm.nih.gov/pubmed/35365908 http://dx.doi.org/10.1002/ijgo.14204 |
_version_ | 1784859211618844672 |
---|---|
author | Raffone, Antonio Raimondo, Diego Raspollini, Arianna Oliviero, Alessia Travaglino, Antonio Santoro, Angela Renzulli, Federica Lopez, Giovanni Maio, Carlo Michele Di Casadio, Paolo Zannoni, Gian Franco Seracchioli, Renato Mollo, Antonio |
author_facet | Raffone, Antonio Raimondo, Diego Raspollini, Arianna Oliviero, Alessia Travaglino, Antonio Santoro, Angela Renzulli, Federica Lopez, Giovanni Maio, Carlo Michele Di Casadio, Paolo Zannoni, Gian Franco Seracchioli, Renato Mollo, Antonio |
author_sort | Raffone, Antonio |
collection | PubMed |
description | Although Tao brush has become one of the most studied and used endometrial cytological samplers, concerns remain about the adequacy of the cytological sample compared with definitive histology. We aimed to assess accuracy of cytological examination from Tao brush sampling in diagnosing endometrial premalignancy and malignancy through a systematic review and meta‐analysis. Seven electronic databases were searched from January 2000 to July 2021 for all studies which allowed assessment of accuracy of Tao brush in diagnosing endometrial premalignancy and malignancy. We calculated sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR−), diagnostic odds ratio (DOR) and area under the curve (AUC) on summary receiver operating characteristic (SROC) curve. Five studies with 774 patients were included. In diagnosing endometrial premalignancy and malignancy, cytological examination from Tao brush endometrial sampling showed pooled sensitivity of 0.95 (95% CI, 0.90–0.98), specificity of 0.92 (95% CI, 0.90–0.94), LR+ of 12.73 (95% CI, 3.94–41.18), LR− of 0.09 (95% CI, 0.05–0.18), DOR of 184.84 (95% CI, 24.37–1401.79), AUC of 0.9757 (standard error: 0.013). In conclusion, cytological examination from Tao brush seems to have a high diagnostic accuracy and might be proposed as both screening and diagnostic tool. However, further studies are necessary to confirm these findings. |
format | Online Article Text |
id | pubmed-9790584 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-97905842022-12-28 Accuracy of cytological examination of Tao brush endometrial sampling in diagnosing endometrial premalignancy and malignancy Raffone, Antonio Raimondo, Diego Raspollini, Arianna Oliviero, Alessia Travaglino, Antonio Santoro, Angela Renzulli, Federica Lopez, Giovanni Maio, Carlo Michele Di Casadio, Paolo Zannoni, Gian Franco Seracchioli, Renato Mollo, Antonio Int J Gynaecol Obstet Review Articles Although Tao brush has become one of the most studied and used endometrial cytological samplers, concerns remain about the adequacy of the cytological sample compared with definitive histology. We aimed to assess accuracy of cytological examination from Tao brush sampling in diagnosing endometrial premalignancy and malignancy through a systematic review and meta‐analysis. Seven electronic databases were searched from January 2000 to July 2021 for all studies which allowed assessment of accuracy of Tao brush in diagnosing endometrial premalignancy and malignancy. We calculated sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR−), diagnostic odds ratio (DOR) and area under the curve (AUC) on summary receiver operating characteristic (SROC) curve. Five studies with 774 patients were included. In diagnosing endometrial premalignancy and malignancy, cytological examination from Tao brush endometrial sampling showed pooled sensitivity of 0.95 (95% CI, 0.90–0.98), specificity of 0.92 (95% CI, 0.90–0.94), LR+ of 12.73 (95% CI, 3.94–41.18), LR− of 0.09 (95% CI, 0.05–0.18), DOR of 184.84 (95% CI, 24.37–1401.79), AUC of 0.9757 (standard error: 0.013). In conclusion, cytological examination from Tao brush seems to have a high diagnostic accuracy and might be proposed as both screening and diagnostic tool. However, further studies are necessary to confirm these findings. John Wiley and Sons Inc. 2022-04-25 2022-12 /pmc/articles/PMC9790584/ /pubmed/35365908 http://dx.doi.org/10.1002/ijgo.14204 Text en © 2022 The Authors. International Journal of Gynecology & Obstetrics published by John Wiley & Sons Ltd on behalf of International Federation of Gynecology and Obstetrics. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Articles Raffone, Antonio Raimondo, Diego Raspollini, Arianna Oliviero, Alessia Travaglino, Antonio Santoro, Angela Renzulli, Federica Lopez, Giovanni Maio, Carlo Michele Di Casadio, Paolo Zannoni, Gian Franco Seracchioli, Renato Mollo, Antonio Accuracy of cytological examination of Tao brush endometrial sampling in diagnosing endometrial premalignancy and malignancy |
title | Accuracy of cytological examination of Tao brush endometrial sampling in diagnosing endometrial premalignancy and malignancy |
title_full | Accuracy of cytological examination of Tao brush endometrial sampling in diagnosing endometrial premalignancy and malignancy |
title_fullStr | Accuracy of cytological examination of Tao brush endometrial sampling in diagnosing endometrial premalignancy and malignancy |
title_full_unstemmed | Accuracy of cytological examination of Tao brush endometrial sampling in diagnosing endometrial premalignancy and malignancy |
title_short | Accuracy of cytological examination of Tao brush endometrial sampling in diagnosing endometrial premalignancy and malignancy |
title_sort | accuracy of cytological examination of tao brush endometrial sampling in diagnosing endometrial premalignancy and malignancy |
topic | Review Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9790584/ https://www.ncbi.nlm.nih.gov/pubmed/35365908 http://dx.doi.org/10.1002/ijgo.14204 |
work_keys_str_mv | AT raffoneantonio accuracyofcytologicalexaminationoftaobrushendometrialsamplingindiagnosingendometrialpremalignancyandmalignancy AT raimondodiego accuracyofcytologicalexaminationoftaobrushendometrialsamplingindiagnosingendometrialpremalignancyandmalignancy AT raspolliniarianna accuracyofcytologicalexaminationoftaobrushendometrialsamplingindiagnosingendometrialpremalignancyandmalignancy AT olivieroalessia accuracyofcytologicalexaminationoftaobrushendometrialsamplingindiagnosingendometrialpremalignancyandmalignancy AT travaglinoantonio accuracyofcytologicalexaminationoftaobrushendometrialsamplingindiagnosingendometrialpremalignancyandmalignancy AT santoroangela accuracyofcytologicalexaminationoftaobrushendometrialsamplingindiagnosingendometrialpremalignancyandmalignancy AT renzullifederica accuracyofcytologicalexaminationoftaobrushendometrialsamplingindiagnosingendometrialpremalignancyandmalignancy AT lopezgiovanni accuracyofcytologicalexaminationoftaobrushendometrialsamplingindiagnosingendometrialpremalignancyandmalignancy AT maiocarlomicheledi accuracyofcytologicalexaminationoftaobrushendometrialsamplingindiagnosingendometrialpremalignancyandmalignancy AT casadiopaolo accuracyofcytologicalexaminationoftaobrushendometrialsamplingindiagnosingendometrialpremalignancyandmalignancy AT zannonigianfranco accuracyofcytologicalexaminationoftaobrushendometrialsamplingindiagnosingendometrialpremalignancyandmalignancy AT seracchiolirenato accuracyofcytologicalexaminationoftaobrushendometrialsamplingindiagnosingendometrialpremalignancyandmalignancy AT molloantonio accuracyofcytologicalexaminationoftaobrushendometrialsamplingindiagnosingendometrialpremalignancyandmalignancy |