Cargando…

Incidental nodal irradiation in patients with esophageal cancer undergoing (chemo)radiation with 3D-CRT or VMAT

The extent of elective nodal irradiation (ENI) in patients undergoing definitive chemoradiotherapy (dCRT) for esophageal squamous cell carcinoma (ESCC) remains unclear. The aim of this dosimetric study was to evaluate the extent of incidental nodal irradiation using modern radiation techniques. A pl...

Descripción completa

Detalles Bibliográficos
Autores principales: Peschel, David Paul, Düsberg, Mathias, Peeken, Jan C., Kaiser, Jan Christian, Borm, Kai Joachim, Sommer, Katharina, Combs, Stephanie E., Münch, Stefan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9790887/
https://www.ncbi.nlm.nih.gov/pubmed/36567356
http://dx.doi.org/10.1038/s41598-022-26641-w
Descripción
Sumario:The extent of elective nodal irradiation (ENI) in patients undergoing definitive chemoradiotherapy (dCRT) for esophageal squamous cell carcinoma (ESCC) remains unclear. The aim of this dosimetric study was to evaluate the extent of incidental nodal irradiation using modern radiation techniques. A planning target volume (PTV) was generated for 30 patients with node-negative esophageal carcinoma (13 cervical/upper third, 7 middle third, 10 lower third/abdomen). Thereby, no elective nodal irradiation (ENI) was intended. Both three-dimensional conformal radiotherapy (3D-CRT) and volumetric-modulated arc therapy (VMAT) treatment plans (50 Gy in 25 fractions) were calculated for all patients. Fifteen nodal stations were contoured according to the definitions of the AJCC and investigated in regard to dosimetric parameters. Compared to 3D-CRT, VMAT was associated with lower dose distribution to the organs at risk (lower D(mean), V20 and V30 for the lungs and lower D(mean) and V30 for the heart). For both techniques, the median D(mean) surpassed 40 Gy in 12 of 15 (80%) nodal stations. However, VMAT resulted in significantly lower D(means) and equivalent uniform doses (EUD) compared to 3D-CRT for eight nodal stations (1L, 2L, 2R, 4L, 7, 8L, 10L, 15), while differences did not reach significance for seven nodal station (1R, 4R, 8U, 8M, 10R, 16). For dCRT of ESCC, the use of VMAT was associated with significantly lower median (incidental) doses to eight of 15 regional lymph node areas compared to 3D-CRT. However, given the small absolute differences, these differences probably do not impair (regional) tumor control rates.