Cargando…
The role of 3D speckle tracking echocardiography in the diagnosis of obstructive sleep apnea and its severity
There is a consistent relationship between obstructive sleep apnea (OSA) and cardiovascular diseases. It is already recognized that OSA may influence the geometry and function of the right ventricle (RV). This has encouraged the development of echocardiographic evaluation for screening of OSA and it...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9791147/ https://www.ncbi.nlm.nih.gov/pubmed/36572720 http://dx.doi.org/10.1038/s41598-022-26940-2 |
_version_ | 1784859336503197696 |
---|---|
author | Chetan, Ioana Maria Gergely-Domokos, Bianca Beyer, Ruxandra Tomoaia, Raluca Cabau, Georgiana Vulturar, Damiana Chis, Ana Lesan, Andrei Vesa, Cristian Stefan Pop, Dana Todea, Doina Adina |
author_facet | Chetan, Ioana Maria Gergely-Domokos, Bianca Beyer, Ruxandra Tomoaia, Raluca Cabau, Georgiana Vulturar, Damiana Chis, Ana Lesan, Andrei Vesa, Cristian Stefan Pop, Dana Todea, Doina Adina |
author_sort | Chetan, Ioana Maria |
collection | PubMed |
description | There is a consistent relationship between obstructive sleep apnea (OSA) and cardiovascular diseases. It is already recognized that OSA may influence the geometry and function of the right ventricle (RV). This has encouraged the development of echocardiographic evaluation for screening of OSA and its severity. Three-dimensional speckle tracking echocardiography (3D STE) is in assumption better, compared with 2D STE, because it overcomes the standard 2D echo limitations. Thus, the purpose of our study is to evaluate whether 3D STE measurements, could predict the positive diagnosis and severity of OSA. We enrolled 69 patients with OSA and 37 healthy volunteers who underwent a cardiorespiratory sleep study. 2DE was performed in all patients. RVEF and 3D RVGLS were measured by 3DSTE. NT pro BNP plasma level was also assessed in all participants. 3D RV GLS (− 13.5% vs. − 22.3%, p < 0.001) and 3D RVEF (31.9% vs. 50%, p < 0.001) were reduced in patients with OSA, compared with normal individuals. 3D Strain parameters showed better correlation to standard 2D variables, than 3D RVEF. Except for NT pro BNP (p = 0.059), all parameters served to distinguish between severe and mild-moderate cases of OSA. 3D STE may be a reliable and accurate method for predicting OSA. Consequently, 3D RV GLS is a good tool of assessing the RV global function in OSA, because it correlates well with other established measurements of RV systolic function. Furthermore, 3D RV GLS was a precise parameter in identifying severe cases of OSA, while NT pro BNP showed no association. |
format | Online Article Text |
id | pubmed-9791147 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-97911472022-12-27 The role of 3D speckle tracking echocardiography in the diagnosis of obstructive sleep apnea and its severity Chetan, Ioana Maria Gergely-Domokos, Bianca Beyer, Ruxandra Tomoaia, Raluca Cabau, Georgiana Vulturar, Damiana Chis, Ana Lesan, Andrei Vesa, Cristian Stefan Pop, Dana Todea, Doina Adina Sci Rep Article There is a consistent relationship between obstructive sleep apnea (OSA) and cardiovascular diseases. It is already recognized that OSA may influence the geometry and function of the right ventricle (RV). This has encouraged the development of echocardiographic evaluation for screening of OSA and its severity. Three-dimensional speckle tracking echocardiography (3D STE) is in assumption better, compared with 2D STE, because it overcomes the standard 2D echo limitations. Thus, the purpose of our study is to evaluate whether 3D STE measurements, could predict the positive diagnosis and severity of OSA. We enrolled 69 patients with OSA and 37 healthy volunteers who underwent a cardiorespiratory sleep study. 2DE was performed in all patients. RVEF and 3D RVGLS were measured by 3DSTE. NT pro BNP plasma level was also assessed in all participants. 3D RV GLS (− 13.5% vs. − 22.3%, p < 0.001) and 3D RVEF (31.9% vs. 50%, p < 0.001) were reduced in patients with OSA, compared with normal individuals. 3D Strain parameters showed better correlation to standard 2D variables, than 3D RVEF. Except for NT pro BNP (p = 0.059), all parameters served to distinguish between severe and mild-moderate cases of OSA. 3D STE may be a reliable and accurate method for predicting OSA. Consequently, 3D RV GLS is a good tool of assessing the RV global function in OSA, because it correlates well with other established measurements of RV systolic function. Furthermore, 3D RV GLS was a precise parameter in identifying severe cases of OSA, while NT pro BNP showed no association. Nature Publishing Group UK 2022-12-26 /pmc/articles/PMC9791147/ /pubmed/36572720 http://dx.doi.org/10.1038/s41598-022-26940-2 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Chetan, Ioana Maria Gergely-Domokos, Bianca Beyer, Ruxandra Tomoaia, Raluca Cabau, Georgiana Vulturar, Damiana Chis, Ana Lesan, Andrei Vesa, Cristian Stefan Pop, Dana Todea, Doina Adina The role of 3D speckle tracking echocardiography in the diagnosis of obstructive sleep apnea and its severity |
title | The role of 3D speckle tracking echocardiography in the diagnosis of obstructive sleep apnea and its severity |
title_full | The role of 3D speckle tracking echocardiography in the diagnosis of obstructive sleep apnea and its severity |
title_fullStr | The role of 3D speckle tracking echocardiography in the diagnosis of obstructive sleep apnea and its severity |
title_full_unstemmed | The role of 3D speckle tracking echocardiography in the diagnosis of obstructive sleep apnea and its severity |
title_short | The role of 3D speckle tracking echocardiography in the diagnosis of obstructive sleep apnea and its severity |
title_sort | role of 3d speckle tracking echocardiography in the diagnosis of obstructive sleep apnea and its severity |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9791147/ https://www.ncbi.nlm.nih.gov/pubmed/36572720 http://dx.doi.org/10.1038/s41598-022-26940-2 |
work_keys_str_mv | AT chetanioanamaria theroleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT gergelydomokosbianca theroleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT beyerruxandra theroleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT tomoaiaraluca theroleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT cabaugeorgiana theroleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT vulturardamiana theroleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT chisana theroleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT lesanandrei theroleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT vesacristianstefan theroleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT popdana theroleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT todeadoinaadina theroleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT chetanioanamaria roleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT gergelydomokosbianca roleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT beyerruxandra roleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT tomoaiaraluca roleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT cabaugeorgiana roleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT vulturardamiana roleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT chisana roleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT lesanandrei roleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT vesacristianstefan roleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT popdana roleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity AT todeadoinaadina roleof3dspeckletrackingechocardiographyinthediagnosisofobstructivesleepapneaanditsseverity |