Cargando…

Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke

BACKGROUND: Transcranial magnetic stimulation (TMS) is often used to examine neurophysiology. We aimed to investigate the inter-rater reliability and agreement of single pulse TMS in hospitalised acute ischemic stroke patients. METHODS: Thirty-one patients with first-time acute ischemic stroke (medi...

Descripción completa

Detalles Bibliográficos
Autores principales: Henriette, Busk, Marianne, Nilsen, Rønne, Pedersen Julie, Glavin, Kristensen Malene, Wesenberg, Kjær Troels, Thorgaard, Skou Søren, Troels, Wienecke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9791285/
https://www.ncbi.nlm.nih.gov/pubmed/36578525
http://dx.doi.org/10.1177/26331055221145002
_version_ 1784859372574212096
author Henriette, Busk
Marianne, Nilsen
Rønne, Pedersen Julie
Glavin, Kristensen Malene
Wesenberg, Kjær Troels
Thorgaard, Skou Søren
Troels, Wienecke
author_facet Henriette, Busk
Marianne, Nilsen
Rønne, Pedersen Julie
Glavin, Kristensen Malene
Wesenberg, Kjær Troels
Thorgaard, Skou Søren
Troels, Wienecke
author_sort Henriette, Busk
collection PubMed
description BACKGROUND: Transcranial magnetic stimulation (TMS) is often used to examine neurophysiology. We aimed to investigate the inter-rater reliability and agreement of single pulse TMS in hospitalised acute ischemic stroke patients. METHODS: Thirty-one patients with first-time acute ischemic stroke (median age 72 (IQR 64-75), 35% females) underwent TMS motor threshold (MT) assessment in 4 muscles bilaterally, conducted by 1 of 2 physiotherapists. Test-retest reliability was evaluated using a two-way random effects model (2,1) absolute agreement-type Interclass Correlation Coefficient (ICC). Standard Error of Measurement (SEM) and Smallest Detectable Change (SDC) were used to evaluate agreement. RESULTS: Reliability, SEM, and SDC of TMS was found to be moderate in right opponens pollicis (0.78 [CI 95% 0.55-0.89], SEM: 4.51, SDC: 12.51), good in right vastus medialis and tibial anterior (0.88 [CI 95% 0.72-0.96], SEM: 2.89, SDC: 8.01 and 0.88 [CI 95% 0.76-0.94], SEM: 2.88, SDC: 7.98 respectively), and excellent in right and left biceps brachii (0.98 [CI 95% 0.96-0.99], SEM: 1.79 SDC: 4.96, and 0.94 [CI 95% 0.89-0.97], SEM: 2.17 SDC: 6.01), opponens pollicis (0.92 [CI 95% 0.83-0.96], SEM: 2.68 SDC: 8.26, vastus medialis (0.92 [CI 95% 0.84-0.96], SEM: 2.87 SDC: 7.95), and tibial anterior (0.93 [CI 95% 0.86-0.96], SEM: 2.51 SDC: 6.95). CONCLUSION: The TMS demonstrated moderate to excellent inter-rater reliability confirming the ability of these measures to reliably discriminate between individuals in the current study sample. Improvements of less than 4.96 to 12.51 could be a result of measurement error and may therefore not be considered a true change.
format Online
Article
Text
id pubmed-9791285
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-97912852022-12-27 Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke Henriette, Busk Marianne, Nilsen Rønne, Pedersen Julie Glavin, Kristensen Malene Wesenberg, Kjær Troels Thorgaard, Skou Søren Troels, Wienecke Neurosci Insights Original Research BACKGROUND: Transcranial magnetic stimulation (TMS) is often used to examine neurophysiology. We aimed to investigate the inter-rater reliability and agreement of single pulse TMS in hospitalised acute ischemic stroke patients. METHODS: Thirty-one patients with first-time acute ischemic stroke (median age 72 (IQR 64-75), 35% females) underwent TMS motor threshold (MT) assessment in 4 muscles bilaterally, conducted by 1 of 2 physiotherapists. Test-retest reliability was evaluated using a two-way random effects model (2,1) absolute agreement-type Interclass Correlation Coefficient (ICC). Standard Error of Measurement (SEM) and Smallest Detectable Change (SDC) were used to evaluate agreement. RESULTS: Reliability, SEM, and SDC of TMS was found to be moderate in right opponens pollicis (0.78 [CI 95% 0.55-0.89], SEM: 4.51, SDC: 12.51), good in right vastus medialis and tibial anterior (0.88 [CI 95% 0.72-0.96], SEM: 2.89, SDC: 8.01 and 0.88 [CI 95% 0.76-0.94], SEM: 2.88, SDC: 7.98 respectively), and excellent in right and left biceps brachii (0.98 [CI 95% 0.96-0.99], SEM: 1.79 SDC: 4.96, and 0.94 [CI 95% 0.89-0.97], SEM: 2.17 SDC: 6.01), opponens pollicis (0.92 [CI 95% 0.83-0.96], SEM: 2.68 SDC: 8.26, vastus medialis (0.92 [CI 95% 0.84-0.96], SEM: 2.87 SDC: 7.95), and tibial anterior (0.93 [CI 95% 0.86-0.96], SEM: 2.51 SDC: 6.95). CONCLUSION: The TMS demonstrated moderate to excellent inter-rater reliability confirming the ability of these measures to reliably discriminate between individuals in the current study sample. Improvements of less than 4.96 to 12.51 could be a result of measurement error and may therefore not be considered a true change. SAGE Publications 2022-12-23 /pmc/articles/PMC9791285/ /pubmed/36578525 http://dx.doi.org/10.1177/26331055221145002 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Research
Henriette, Busk
Marianne, Nilsen
Rønne, Pedersen Julie
Glavin, Kristensen Malene
Wesenberg, Kjær Troels
Thorgaard, Skou Søren
Troels, Wienecke
Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke
title Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke
title_full Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke
title_fullStr Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke
title_full_unstemmed Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke
title_short Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke
title_sort test-retest reliability and agreement of single pulse transcranial magnetic stimulation (tms) for measuring activity in motor cortex in patients with acute ischemic stroke
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9791285/
https://www.ncbi.nlm.nih.gov/pubmed/36578525
http://dx.doi.org/10.1177/26331055221145002
work_keys_str_mv AT henriettebusk testretestreliabilityandagreementofsinglepulsetranscranialmagneticstimulationtmsformeasuringactivityinmotorcortexinpatientswithacuteischemicstroke
AT mariannenilsen testretestreliabilityandagreementofsinglepulsetranscranialmagneticstimulationtmsformeasuringactivityinmotorcortexinpatientswithacuteischemicstroke
AT rønnepedersenjulie testretestreliabilityandagreementofsinglepulsetranscranialmagneticstimulationtmsformeasuringactivityinmotorcortexinpatientswithacuteischemicstroke
AT glavinkristensenmalene testretestreliabilityandagreementofsinglepulsetranscranialmagneticstimulationtmsformeasuringactivityinmotorcortexinpatientswithacuteischemicstroke
AT wesenbergkjærtroels testretestreliabilityandagreementofsinglepulsetranscranialmagneticstimulationtmsformeasuringactivityinmotorcortexinpatientswithacuteischemicstroke
AT thorgaardskousøren testretestreliabilityandagreementofsinglepulsetranscranialmagneticstimulationtmsformeasuringactivityinmotorcortexinpatientswithacuteischemicstroke
AT troelswienecke testretestreliabilityandagreementofsinglepulsetranscranialmagneticstimulationtmsformeasuringactivityinmotorcortexinpatientswithacuteischemicstroke