All-Suture Suspensory Button Has Similar Biomechanical Performance to Metal Suspensory Button for Onlay Subpectoral Biceps Tenodesis

PURPOSE: To evaluate the maximal load at failure, cyclic displacement, and stiffness of onlay subpectoral biceps tenodesis (BT) with an intramedullary unicortical metal button (MB) versus a unicortical all-suture button (ASB). METHODS: Eighteen matched paired human cadaveric proximal humeri were ran...

Descripción completa

Detalles Bibliográficos
Autores principales: Colantonio, Donald F., Tucker, Christopher J., Murphy, Timothy P., Mescher, Patrick K., Le, Anthony H., Putko, Robert M., Holm, Erik R., Weishar, Robert, Vippa, Tarun K., Rudic, Theodore N., Chang, Edward S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9791876/
https://www.ncbi.nlm.nih.gov/pubmed/36579049
http://dx.doi.org/10.1016/j.asmr.2022.09.004
_version_ 1784859511914233856
author Colantonio, Donald F.
Tucker, Christopher J.
Murphy, Timothy P.
Mescher, Patrick K.
Le, Anthony H.
Putko, Robert M.
Holm, Erik R.
Weishar, Robert
Vippa, Tarun K.
Rudic, Theodore N.
Chang, Edward S.
author_facet Colantonio, Donald F.
Tucker, Christopher J.
Murphy, Timothy P.
Mescher, Patrick K.
Le, Anthony H.
Putko, Robert M.
Holm, Erik R.
Weishar, Robert
Vippa, Tarun K.
Rudic, Theodore N.
Chang, Edward S.
author_sort Colantonio, Donald F.
collection PubMed
description PURPOSE: To evaluate the maximal load at failure, cyclic displacement, and stiffness of onlay subpectoral biceps tenodesis (BT) with an intramedullary unicortical metal button (MB) versus a unicortical all-suture button (ASB). METHODS: Eighteen matched paired human cadaveric proximal humeri were randomly allocated for subpectoral BT with either ASB or MB using a high-strength suture. Specimens were tested on a servohydraulic mechanical testing apparatus under cyclic load for 1,000 cycles and then loaded to failure. The clamp was then adjusted to isolate the suture–anchor point interface and loaded to failure. Maximal load to failure, displacement, and stiffness were compared. RESULTS: There was no significant difference between groups in stiffness, displacement, or yield load. The maximal load to failure for the MB was greater than the ASB (347.6 ± 74.1N vs 266.5 ± 69.3N, P = .047). Eight specimens in each group failed by suture pull-through on the tendon. When the suture–anchor point interface was isolated, there was no significant difference in maximal load at failure (MB 586.5 ± 215.8N vs ASB 579.6 ± 255.9N, P = .957). CONCLUSIONS: This study demonstrates that the MB and ASB have similar biomechanical performance when used in subpectoral BT. Although the MB showed statistically significant greater maximal load to failure, there was no difference between the MB and ASB when the suture–tendon interface was eliminated. Suture pull-through was the most common mode of failure for both implants, underscoring the importance of the suture–tendon interface. CLINICAL RELEVANCE: Fixation techniques for the treatment of long head of the biceps brachii tenodesis continue to evolve. The use of an all-suture suspensory button has advantages, but it is important to understand if this implant is a biomechanically suitable alternative to a metal suspensory button.
format Online
Article
Text
id pubmed-9791876
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-97918762022-12-27 All-Suture Suspensory Button Has Similar Biomechanical Performance to Metal Suspensory Button for Onlay Subpectoral Biceps Tenodesis Colantonio, Donald F. Tucker, Christopher J. Murphy, Timothy P. Mescher, Patrick K. Le, Anthony H. Putko, Robert M. Holm, Erik R. Weishar, Robert Vippa, Tarun K. Rudic, Theodore N. Chang, Edward S. Arthrosc Sports Med Rehabil Original Article PURPOSE: To evaluate the maximal load at failure, cyclic displacement, and stiffness of onlay subpectoral biceps tenodesis (BT) with an intramedullary unicortical metal button (MB) versus a unicortical all-suture button (ASB). METHODS: Eighteen matched paired human cadaveric proximal humeri were randomly allocated for subpectoral BT with either ASB or MB using a high-strength suture. Specimens were tested on a servohydraulic mechanical testing apparatus under cyclic load for 1,000 cycles and then loaded to failure. The clamp was then adjusted to isolate the suture–anchor point interface and loaded to failure. Maximal load to failure, displacement, and stiffness were compared. RESULTS: There was no significant difference between groups in stiffness, displacement, or yield load. The maximal load to failure for the MB was greater than the ASB (347.6 ± 74.1N vs 266.5 ± 69.3N, P = .047). Eight specimens in each group failed by suture pull-through on the tendon. When the suture–anchor point interface was isolated, there was no significant difference in maximal load at failure (MB 586.5 ± 215.8N vs ASB 579.6 ± 255.9N, P = .957). CONCLUSIONS: This study demonstrates that the MB and ASB have similar biomechanical performance when used in subpectoral BT. Although the MB showed statistically significant greater maximal load to failure, there was no difference between the MB and ASB when the suture–tendon interface was eliminated. Suture pull-through was the most common mode of failure for both implants, underscoring the importance of the suture–tendon interface. CLINICAL RELEVANCE: Fixation techniques for the treatment of long head of the biceps brachii tenodesis continue to evolve. The use of an all-suture suspensory button has advantages, but it is important to understand if this implant is a biomechanically suitable alternative to a metal suspensory button. Elsevier 2022-10-18 /pmc/articles/PMC9791876/ /pubmed/36579049 http://dx.doi.org/10.1016/j.asmr.2022.09.004 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Colantonio, Donald F.
Tucker, Christopher J.
Murphy, Timothy P.
Mescher, Patrick K.
Le, Anthony H.
Putko, Robert M.
Holm, Erik R.
Weishar, Robert
Vippa, Tarun K.
Rudic, Theodore N.
Chang, Edward S.
All-Suture Suspensory Button Has Similar Biomechanical Performance to Metal Suspensory Button for Onlay Subpectoral Biceps Tenodesis
title All-Suture Suspensory Button Has Similar Biomechanical Performance to Metal Suspensory Button for Onlay Subpectoral Biceps Tenodesis
title_full All-Suture Suspensory Button Has Similar Biomechanical Performance to Metal Suspensory Button for Onlay Subpectoral Biceps Tenodesis
title_fullStr All-Suture Suspensory Button Has Similar Biomechanical Performance to Metal Suspensory Button for Onlay Subpectoral Biceps Tenodesis
title_full_unstemmed All-Suture Suspensory Button Has Similar Biomechanical Performance to Metal Suspensory Button for Onlay Subpectoral Biceps Tenodesis
title_short All-Suture Suspensory Button Has Similar Biomechanical Performance to Metal Suspensory Button for Onlay Subpectoral Biceps Tenodesis
title_sort all-suture suspensory button has similar biomechanical performance to metal suspensory button for onlay subpectoral biceps tenodesis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9791876/
https://www.ncbi.nlm.nih.gov/pubmed/36579049
http://dx.doi.org/10.1016/j.asmr.2022.09.004
work_keys_str_mv AT colantoniodonaldf allsuturesuspensorybuttonhassimilarbiomechanicalperformancetometalsuspensorybuttonforonlaysubpectoralbicepstenodesis
AT tuckerchristopherj allsuturesuspensorybuttonhassimilarbiomechanicalperformancetometalsuspensorybuttonforonlaysubpectoralbicepstenodesis
AT murphytimothyp allsuturesuspensorybuttonhassimilarbiomechanicalperformancetometalsuspensorybuttonforonlaysubpectoralbicepstenodesis
AT mescherpatrickk allsuturesuspensorybuttonhassimilarbiomechanicalperformancetometalsuspensorybuttonforonlaysubpectoralbicepstenodesis
AT leanthonyh allsuturesuspensorybuttonhassimilarbiomechanicalperformancetometalsuspensorybuttonforonlaysubpectoralbicepstenodesis
AT putkorobertm allsuturesuspensorybuttonhassimilarbiomechanicalperformancetometalsuspensorybuttonforonlaysubpectoralbicepstenodesis
AT holmerikr allsuturesuspensorybuttonhassimilarbiomechanicalperformancetometalsuspensorybuttonforonlaysubpectoralbicepstenodesis
AT weisharrobert allsuturesuspensorybuttonhassimilarbiomechanicalperformancetometalsuspensorybuttonforonlaysubpectoralbicepstenodesis
AT vippatarunk allsuturesuspensorybuttonhassimilarbiomechanicalperformancetometalsuspensorybuttonforonlaysubpectoralbicepstenodesis
AT rudictheodoren allsuturesuspensorybuttonhassimilarbiomechanicalperformancetometalsuspensorybuttonforonlaysubpectoralbicepstenodesis
AT changedwards allsuturesuspensorybuttonhassimilarbiomechanicalperformancetometalsuspensorybuttonforonlaysubpectoralbicepstenodesis