Cargando…

Reliability of Bigliani’s Classification using Magnetic Resonance Imaging for Determination of Acromial Morphology

INTRODUCTION: Bigliani classification is used for determination of acromial morphology, but poor inter-observer reliability has been reported on conventional radiographs. This study aims to assess inter- and intra-observer reliability using magnetic resonance imaging (MRI). MATERIALS AND METHODS: Fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Sahin, K, Kendirci, AS, Kocazeybek, E, Demir, N, Saglam, Y, Ersen, A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Malaysian Orthopaedic Association 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9791892/
https://www.ncbi.nlm.nih.gov/pubmed/36589385
http://dx.doi.org/10.5704/MOJ.2211.008
_version_ 1784859515817033728
author Sahin, K
Kendirci, AS
Kocazeybek, E
Demir, N
Saglam, Y
Ersen, A
author_facet Sahin, K
Kendirci, AS
Kocazeybek, E
Demir, N
Saglam, Y
Ersen, A
author_sort Sahin, K
collection PubMed
description INTRODUCTION: Bigliani classification is used for determination of acromial morphology, but poor inter-observer reliability has been reported on conventional radiographs. This study aims to assess inter- and intra-observer reliability using magnetic resonance imaging (MRI). MATERIALS AND METHODS: Forty consecutive patients diagnosed with subacromial impingement syndrome were included to study. All subjects underwent standard shoulder MRI scan and acromial shape was evaluated by nine observers of different level of expertise (three attending surgeons, three senior orthopaedic residents and three radiologists). A second set of evaluation was performed in order to assess intra-observer reproducibility. Kappa (κ) coefficient analyses both for interobserver reliability and intra-observer reproducibility were then performed. RESULTS: Overall inter-observer agreement among nine observers was fair (κ=0.323). κ values for all 4 individual types ranged from 0.234 to 0.720 with highest agreement for type 4 and lowest agreement for type 3. Second evaluation did not result with an increase of inter-observer agreement (κ=0.338, fair). The κ coefficients for intra-observer reproducibility of nine observers ranged from 0.496 to 0.867. Overall intra-observer reproducibility was substantial. Comparison of inter- and intra-observer reliability among three groups showed no significant difference (p=0.92 and 0.22, respectively). CONCLUSION: Results showed that MRI did not show superior reliability compared to conventional radiographs. Moreover, inter- and intra-observer agreement did not differ between observers of different level of expertise. Findings of present study suggest that despite a sophisticated imaging modality like MRI, Bigliani’s classification apparently lacks accuracy and additional criteria, or different assessment methods are required to assess acromial morphology for clinical guidance.
format Online
Article
Text
id pubmed-9791892
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Malaysian Orthopaedic Association
record_format MEDLINE/PubMed
spelling pubmed-97918922022-12-30 Reliability of Bigliani’s Classification using Magnetic Resonance Imaging for Determination of Acromial Morphology Sahin, K Kendirci, AS Kocazeybek, E Demir, N Saglam, Y Ersen, A Malays Orthop J Original Study INTRODUCTION: Bigliani classification is used for determination of acromial morphology, but poor inter-observer reliability has been reported on conventional radiographs. This study aims to assess inter- and intra-observer reliability using magnetic resonance imaging (MRI). MATERIALS AND METHODS: Forty consecutive patients diagnosed with subacromial impingement syndrome were included to study. All subjects underwent standard shoulder MRI scan and acromial shape was evaluated by nine observers of different level of expertise (three attending surgeons, three senior orthopaedic residents and three radiologists). A second set of evaluation was performed in order to assess intra-observer reproducibility. Kappa (κ) coefficient analyses both for interobserver reliability and intra-observer reproducibility were then performed. RESULTS: Overall inter-observer agreement among nine observers was fair (κ=0.323). κ values for all 4 individual types ranged from 0.234 to 0.720 with highest agreement for type 4 and lowest agreement for type 3. Second evaluation did not result with an increase of inter-observer agreement (κ=0.338, fair). The κ coefficients for intra-observer reproducibility of nine observers ranged from 0.496 to 0.867. Overall intra-observer reproducibility was substantial. Comparison of inter- and intra-observer reliability among three groups showed no significant difference (p=0.92 and 0.22, respectively). CONCLUSION: Results showed that MRI did not show superior reliability compared to conventional radiographs. Moreover, inter- and intra-observer agreement did not differ between observers of different level of expertise. Findings of present study suggest that despite a sophisticated imaging modality like MRI, Bigliani’s classification apparently lacks accuracy and additional criteria, or different assessment methods are required to assess acromial morphology for clinical guidance. Malaysian Orthopaedic Association 2022-11 /pmc/articles/PMC9791892/ /pubmed/36589385 http://dx.doi.org/10.5704/MOJ.2211.008 Text en © 2022 Malaysian Orthopaedic Association (MOA). All Rights Reserved https://creativecommons.org/licenses/by/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited
spellingShingle Original Study
Sahin, K
Kendirci, AS
Kocazeybek, E
Demir, N
Saglam, Y
Ersen, A
Reliability of Bigliani’s Classification using Magnetic Resonance Imaging for Determination of Acromial Morphology
title Reliability of Bigliani’s Classification using Magnetic Resonance Imaging for Determination of Acromial Morphology
title_full Reliability of Bigliani’s Classification using Magnetic Resonance Imaging for Determination of Acromial Morphology
title_fullStr Reliability of Bigliani’s Classification using Magnetic Resonance Imaging for Determination of Acromial Morphology
title_full_unstemmed Reliability of Bigliani’s Classification using Magnetic Resonance Imaging for Determination of Acromial Morphology
title_short Reliability of Bigliani’s Classification using Magnetic Resonance Imaging for Determination of Acromial Morphology
title_sort reliability of bigliani’s classification using magnetic resonance imaging for determination of acromial morphology
topic Original Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9791892/
https://www.ncbi.nlm.nih.gov/pubmed/36589385
http://dx.doi.org/10.5704/MOJ.2211.008
work_keys_str_mv AT sahink reliabilityofbiglianisclassificationusingmagneticresonanceimagingfordeterminationofacromialmorphology
AT kendircias reliabilityofbiglianisclassificationusingmagneticresonanceimagingfordeterminationofacromialmorphology
AT kocazeybeke reliabilityofbiglianisclassificationusingmagneticresonanceimagingfordeterminationofacromialmorphology
AT demirn reliabilityofbiglianisclassificationusingmagneticresonanceimagingfordeterminationofacromialmorphology
AT saglamy reliabilityofbiglianisclassificationusingmagneticresonanceimagingfordeterminationofacromialmorphology
AT ersena reliabilityofbiglianisclassificationusingmagneticresonanceimagingfordeterminationofacromialmorphology