Cargando…

The Relation between the Radial Collapse and the Number of Metaphyseal Screws for Distal Radius Fractures

INTRODUCTION: The purpose of this study is the evaluation of radial collapse, based on the number of screws used in the metaphyseal region and by distal dorsal distance (DDD) and lunate facet distance (LFD) measurement. MATERIALS AND METHODS: Between 2015 and 2019, 60 patients who were being treated...

Descripción completa

Detalles Bibliográficos
Autores principales: Askin, A, Aldemir, C, Duygun, F, Nabi, V
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Malaysian Orthopaedic Association 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9791896/
https://www.ncbi.nlm.nih.gov/pubmed/36589376
http://dx.doi.org/10.5704/MOJ.2211.006
_version_ 1784859516783820800
author Askin, A
Aldemir, C
Duygun, F
Nabi, V
author_facet Askin, A
Aldemir, C
Duygun, F
Nabi, V
author_sort Askin, A
collection PubMed
description INTRODUCTION: The purpose of this study is the evaluation of radial collapse, based on the number of screws used in the metaphyseal region and by distal dorsal distance (DDD) and lunate facet distance (LFD) measurement. MATERIALS AND METHODS: Between 2015 and 2019, 60 patients who were being treated with volar locking plates due to isolated distal radius fracture were evaluated. Control radiographs were taken on the first day and at 3rd-, 6th- and 12th-month follow-ups. Distal dorsal cortex distance and lunate facet distance were measured in the lateral radiographs. The number of screws used in the metaphyseal region was also evaluated. According to the number of screws, the amount of collapse was analysed based on both the LFD and the DDD. RESULTS: The mean age of patients was 43.5±12.7 years. Thirty-three of the patients included in the study were male and 27 were female, and the minimum follow-up period was one year. According to the mean number of screws, groups were defined as up to 6 screws or 7 screws and above. There was a statistically significant difference between the groups in terms of DDD collapse at the 6th-month and 12th-month follow-ups (p<0.005). It was observed that the radial collapse and decrease in DDD and LFD were lower in plates with seven screws and above. CONCLUSION: Decreases in either DDD or LFD, or radial collapse were observed less in patients who had seven or more metaphyseal screws inserted. These findings might be useful for surgeons treating distal radius fractures to reduce radial collapse.
format Online
Article
Text
id pubmed-9791896
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Malaysian Orthopaedic Association
record_format MEDLINE/PubMed
spelling pubmed-97918962022-12-30 The Relation between the Radial Collapse and the Number of Metaphyseal Screws for Distal Radius Fractures Askin, A Aldemir, C Duygun, F Nabi, V Malays Orthop J Original Study INTRODUCTION: The purpose of this study is the evaluation of radial collapse, based on the number of screws used in the metaphyseal region and by distal dorsal distance (DDD) and lunate facet distance (LFD) measurement. MATERIALS AND METHODS: Between 2015 and 2019, 60 patients who were being treated with volar locking plates due to isolated distal radius fracture were evaluated. Control radiographs were taken on the first day and at 3rd-, 6th- and 12th-month follow-ups. Distal dorsal cortex distance and lunate facet distance were measured in the lateral radiographs. The number of screws used in the metaphyseal region was also evaluated. According to the number of screws, the amount of collapse was analysed based on both the LFD and the DDD. RESULTS: The mean age of patients was 43.5±12.7 years. Thirty-three of the patients included in the study were male and 27 were female, and the minimum follow-up period was one year. According to the mean number of screws, groups were defined as up to 6 screws or 7 screws and above. There was a statistically significant difference between the groups in terms of DDD collapse at the 6th-month and 12th-month follow-ups (p<0.005). It was observed that the radial collapse and decrease in DDD and LFD were lower in plates with seven screws and above. CONCLUSION: Decreases in either DDD or LFD, or radial collapse were observed less in patients who had seven or more metaphyseal screws inserted. These findings might be useful for surgeons treating distal radius fractures to reduce radial collapse. Malaysian Orthopaedic Association 2022-11 /pmc/articles/PMC9791896/ /pubmed/36589376 http://dx.doi.org/10.5704/MOJ.2211.006 Text en © 2022 Malaysian Orthopaedic Association (MOA). All Rights Reserved https://creativecommons.org/licenses/by/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited
spellingShingle Original Study
Askin, A
Aldemir, C
Duygun, F
Nabi, V
The Relation between the Radial Collapse and the Number of Metaphyseal Screws for Distal Radius Fractures
title The Relation between the Radial Collapse and the Number of Metaphyseal Screws for Distal Radius Fractures
title_full The Relation between the Radial Collapse and the Number of Metaphyseal Screws for Distal Radius Fractures
title_fullStr The Relation between the Radial Collapse and the Number of Metaphyseal Screws for Distal Radius Fractures
title_full_unstemmed The Relation between the Radial Collapse and the Number of Metaphyseal Screws for Distal Radius Fractures
title_short The Relation between the Radial Collapse and the Number of Metaphyseal Screws for Distal Radius Fractures
title_sort relation between the radial collapse and the number of metaphyseal screws for distal radius fractures
topic Original Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9791896/
https://www.ncbi.nlm.nih.gov/pubmed/36589376
http://dx.doi.org/10.5704/MOJ.2211.006
work_keys_str_mv AT askina therelationbetweentheradialcollapseandthenumberofmetaphysealscrewsfordistalradiusfractures
AT aldemirc therelationbetweentheradialcollapseandthenumberofmetaphysealscrewsfordistalradiusfractures
AT duygunf therelationbetweentheradialcollapseandthenumberofmetaphysealscrewsfordistalradiusfractures
AT nabiv therelationbetweentheradialcollapseandthenumberofmetaphysealscrewsfordistalradiusfractures
AT askina relationbetweentheradialcollapseandthenumberofmetaphysealscrewsfordistalradiusfractures
AT aldemirc relationbetweentheradialcollapseandthenumberofmetaphysealscrewsfordistalradiusfractures
AT duygunf relationbetweentheradialcollapseandthenumberofmetaphysealscrewsfordistalradiusfractures
AT nabiv relationbetweentheradialcollapseandthenumberofmetaphysealscrewsfordistalradiusfractures