Cargando…

Robust dual‐module velocity‐selective arterial spin labeling (dm‐VSASL) with velocity‐selective saturation and inversion

PURPOSE: Compared to conventional arterial spin labeling (ASL) methods, velocity‐selective ASL (VSASL) is more sensitive to artifacts from eddy currents, diffusion attenuation, and motion. Background suppression is typically suboptimal in VSASL, especially of CSF. As a result, the temporal SNR and q...

Descripción completa

Detalles Bibliográficos
Autor principal: Guo, Jia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9792445/
https://www.ncbi.nlm.nih.gov/pubmed/36336852
http://dx.doi.org/10.1002/mrm.29513
_version_ 1784859634844041216
author Guo, Jia
author_facet Guo, Jia
author_sort Guo, Jia
collection PubMed
description PURPOSE: Compared to conventional arterial spin labeling (ASL) methods, velocity‐selective ASL (VSASL) is more sensitive to artifacts from eddy currents, diffusion attenuation, and motion. Background suppression is typically suboptimal in VSASL, especially of CSF. As a result, the temporal SNR and quantification accuracy of VSASL are compromised, hindering its application despite its advantage of being delay‐insensitive. METHODS: A novel dual‐module VSASL (dm‐VSASL) strategy is developed to improve the SNR efficiency and the temporal SNR with a more balanced gradient configuration in the label/control image acquisition. This strategy applies for both VS saturation (VSS) and VS inversion (VSI) labeling. The dm‐VSASL schemes were compared with single‐module labeling and a previously developed multi‐module schemes for the SNR performance, background suppression efficacy, and sensitivity to artifacts in simulation and in vivo experiments, using pulsed ASL as the reference. RESULTS: Dm‐VSASL enabled more robust labeling and efficient backgroud suppre across brain tissues, especially of CSF, resulting in significantly reduced artifacts and improved temporal SNR. Compared to single‐module labeling, dm‐VSASL significantly improved the temporal SNR in gray (by 90.8% and 94.9% for dm‐VSS and dm‐VSI, respectively; P < 0.001) and white (by 41.5% and 55.1% for dm‐VSS and dm‐VSI, respectively; P < 0.002) matter. Dm‐VSI also improved the SNR of VSI by 5.4% (P = 0.018). CONCLUSION: Dm‐VSASL can significantly improve the robustness of VS labeling, reduce artifacts, and allow efficient background suppression. When implemented with VSI, it provides the highest SNR efficiency among VSASL methods. Dm‐VSASL is a powerful ASL method for robust, accurate, and delay‐insensitive perfusion mapping.
format Online
Article
Text
id pubmed-9792445
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-97924452023-04-14 Robust dual‐module velocity‐selective arterial spin labeling (dm‐VSASL) with velocity‐selective saturation and inversion Guo, Jia Magn Reson Med Research Articles—Imaging Methodology PURPOSE: Compared to conventional arterial spin labeling (ASL) methods, velocity‐selective ASL (VSASL) is more sensitive to artifacts from eddy currents, diffusion attenuation, and motion. Background suppression is typically suboptimal in VSASL, especially of CSF. As a result, the temporal SNR and quantification accuracy of VSASL are compromised, hindering its application despite its advantage of being delay‐insensitive. METHODS: A novel dual‐module VSASL (dm‐VSASL) strategy is developed to improve the SNR efficiency and the temporal SNR with a more balanced gradient configuration in the label/control image acquisition. This strategy applies for both VS saturation (VSS) and VS inversion (VSI) labeling. The dm‐VSASL schemes were compared with single‐module labeling and a previously developed multi‐module schemes for the SNR performance, background suppression efficacy, and sensitivity to artifacts in simulation and in vivo experiments, using pulsed ASL as the reference. RESULTS: Dm‐VSASL enabled more robust labeling and efficient backgroud suppre across brain tissues, especially of CSF, resulting in significantly reduced artifacts and improved temporal SNR. Compared to single‐module labeling, dm‐VSASL significantly improved the temporal SNR in gray (by 90.8% and 94.9% for dm‐VSS and dm‐VSI, respectively; P < 0.001) and white (by 41.5% and 55.1% for dm‐VSS and dm‐VSI, respectively; P < 0.002) matter. Dm‐VSI also improved the SNR of VSI by 5.4% (P = 0.018). CONCLUSION: Dm‐VSASL can significantly improve the robustness of VS labeling, reduce artifacts, and allow efficient background suppression. When implemented with VSI, it provides the highest SNR efficiency among VSASL methods. Dm‐VSASL is a powerful ASL method for robust, accurate, and delay‐insensitive perfusion mapping. John Wiley and Sons Inc. 2022-11-06 2023-03 /pmc/articles/PMC9792445/ /pubmed/36336852 http://dx.doi.org/10.1002/mrm.29513 Text en © 2022 The Author. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles—Imaging Methodology
Guo, Jia
Robust dual‐module velocity‐selective arterial spin labeling (dm‐VSASL) with velocity‐selective saturation and inversion
title Robust dual‐module velocity‐selective arterial spin labeling (dm‐VSASL) with velocity‐selective saturation and inversion
title_full Robust dual‐module velocity‐selective arterial spin labeling (dm‐VSASL) with velocity‐selective saturation and inversion
title_fullStr Robust dual‐module velocity‐selective arterial spin labeling (dm‐VSASL) with velocity‐selective saturation and inversion
title_full_unstemmed Robust dual‐module velocity‐selective arterial spin labeling (dm‐VSASL) with velocity‐selective saturation and inversion
title_short Robust dual‐module velocity‐selective arterial spin labeling (dm‐VSASL) with velocity‐selective saturation and inversion
title_sort robust dual‐module velocity‐selective arterial spin labeling (dm‐vsasl) with velocity‐selective saturation and inversion
topic Research Articles—Imaging Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9792445/
https://www.ncbi.nlm.nih.gov/pubmed/36336852
http://dx.doi.org/10.1002/mrm.29513
work_keys_str_mv AT guojia robustdualmodulevelocityselectivearterialspinlabelingdmvsaslwithvelocityselectivesaturationandinversion