Cargando…

Pulsatile energy consumption as a surrogate marker for vascular afterload improves with time post transcatheter aortic valve replacement in patients with aortic stenosis

The effect of arterial stiffening on elevated pulsatile left ventricular afterload patients with aortic stenosis (AS) is pronounced beyond systemic hypertension. Circulatory afterload pulsatile efficiency (CAPE) is a marker of vascular function, defined as the ratio of steady state energy consumptio...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, Ning, Adji, Audrey I., Hungerford, Sara L., Namasivayam, Mayooran J., Hayward, Christopher S., Jabbour, Andrew, Muller, David W. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Nature Singapore 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9793818/
https://www.ncbi.nlm.nih.gov/pubmed/36575229
http://dx.doi.org/10.1038/s41440-022-01127-4
Descripción
Sumario:The effect of arterial stiffening on elevated pulsatile left ventricular afterload patients with aortic stenosis (AS) is pronounced beyond systemic hypertension. Circulatory afterload pulsatile efficiency (CAPE) is a marker of vascular function, defined as the ratio of steady state energy consumption (SEC) to maintain systemic circulation and pulsatile energy consumption (PEC). Twenty patients aged 80 ± 7 years were assessed at baseline and a median of 60 days post transcatheter aortic valve replacement (TAVR), with pulsatile vascular load calculated using simultaneous radial applanation tonometry derived aortic pressure and cardiac magnetic resonance phase-contrast imaging derived ascending aortic flow. Eight out of 20 patients had a reduction in PEC post TAVR, and the reduction of PEC correlated strongly with the number of days post TAVR (R = 0.62, P < 0.01). Patients assessed within the 100 days of TAVR had a rise in their PEC when compared to baseline (0.19 ± 0.09 vs 0.14 ± 0.08 W, P = 0.04). Baseline PEC correlated moderately with baseline SEC (R = 0.49, P = 0.03), and a high baseline PEC was predictive of post TAVR PEC reduction (R = 0.54, P =0.01). Overall, no significant differences were found between baseline and post TAVR for systolic aortic pressure (131 ± 20 vs 131 ± 20 mmHg), systemic vascular resistance (1894 ± 493 vs 2015 ± 519 dynes.s/cm(5)), aortic valve ejection time (337 ± 22 vs 324 ± 34 ms) or aortic characteristic impedance (120 ± 48 vs 107 ± 41 dynes.s/cm(5)). Improved flow profiles after TAVR likely unmask the true vascular properties by altering ventriculo-valvulo-arterial coupling, leading to downstream vascular remodelling secondary to flow conditioning, and results in eventual improvement of pulsatile afterload as reflected by our proposed index of CAPE. [Image: see text]