Leadless biventricular left bundle and endocardial lateral wall pacing versus left bundle only pacing in left bundle branch block patients
Biventricular endocardial (BIV-endo) pacing and left bundle pacing (LBP) are novel delivery methods for cardiac resynchronization therapy (CRT). Both pacing methods can be delivered through leadless pacing, to avoid risks associated with endocardial or transvenous leads. We used computational modell...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9794756/ https://www.ncbi.nlm.nih.gov/pubmed/36589454 http://dx.doi.org/10.3389/fphys.2022.1049214 |
_version_ | 1784860100549148672 |
---|---|
author | Strocchi, Marina Wijesuriya, Nadeev Elliott, Mark K. Gillette, Karli Neic, Aurel Mehta, Vishal Vigmond, Edward J. Plank, Gernot Rinaldi, Christopher A. Niederer, Steven A. |
author_facet | Strocchi, Marina Wijesuriya, Nadeev Elliott, Mark K. Gillette, Karli Neic, Aurel Mehta, Vishal Vigmond, Edward J. Plank, Gernot Rinaldi, Christopher A. Niederer, Steven A. |
author_sort | Strocchi, Marina |
collection | PubMed |
description | Biventricular endocardial (BIV-endo) pacing and left bundle pacing (LBP) are novel delivery methods for cardiac resynchronization therapy (CRT). Both pacing methods can be delivered through leadless pacing, to avoid risks associated with endocardial or transvenous leads. We used computational modelling to quantify synchrony induced by BIV-endo pacing and LBP through a leadless pacing system, and to investigate how the right-left ventricle (RV-LV) delay, RV lead location and type of left bundle capture affect response. We simulated ventricular activation on twenty-four four-chamber heart meshes inclusive of His-Purkinje networks with left bundle branch block (LBBB). Leadless biventricular (BIV) pacing was simulated by adding an RV apical stimulus and an LV lateral wall stimulus (BIV-endo lateral) or targeting the left bundle (BIV-LBP), with an RV-LV delay set to 5 ms. To test effect of prolonged RV-LV delays and RV pacing location, the RV-LV delay was increased to 35 ms and/or the RV stimulus was moved to the RV septum. BIV-endo lateral pacing was less sensitive to increased RV-LV delays, while RV septal pacing worsened response compared to RV apical pacing, especially for long RV-LV delays. To investigate how left bundle capture affects response, we computed 90% BIV activation times (BIVAT-90) during BIV-LBP with selective and non-selective capture, and left bundle branch area pacing (LBBAP), simulated by pacing 1 cm below the left bundle. Non-selective LBP was comparable to selective LBP. LBBAP was worse than selective LBP (BIVAT-90: 54.2 ± 5.7 ms vs. 62.7 ± 6.5, p < 0.01), but it still significantly reduced activation times from baseline. Finally, we compared leadless LBP with RV pacing against optimal LBP delivery through a standard lead system by simulating BIV-LBP and selective LBP alone with and without optimized atrioventricular delay (AVD). Although LBP alone with optimized AVD was better than BIV-LBP, when AVD optimization was not possible BIV-LBP outperformed LBP alone, because the RV pacing stimulus shortened RV activation (BIVAT-90: 54.2 ± 5.7 ms vs. 66.9 ± 5.1 ms, p < 0.01). BIV-endo lateral pacing or LBP delivered through a leadless system could potentially become an alternative to standard CRT. RV-LV delay, RV lead location and type of left bundle capture affect leadless pacing efficacy and should be considered in future trial designs. |
format | Online Article Text |
id | pubmed-9794756 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-97947562022-12-29 Leadless biventricular left bundle and endocardial lateral wall pacing versus left bundle only pacing in left bundle branch block patients Strocchi, Marina Wijesuriya, Nadeev Elliott, Mark K. Gillette, Karli Neic, Aurel Mehta, Vishal Vigmond, Edward J. Plank, Gernot Rinaldi, Christopher A. Niederer, Steven A. Front Physiol Physiology Biventricular endocardial (BIV-endo) pacing and left bundle pacing (LBP) are novel delivery methods for cardiac resynchronization therapy (CRT). Both pacing methods can be delivered through leadless pacing, to avoid risks associated with endocardial or transvenous leads. We used computational modelling to quantify synchrony induced by BIV-endo pacing and LBP through a leadless pacing system, and to investigate how the right-left ventricle (RV-LV) delay, RV lead location and type of left bundle capture affect response. We simulated ventricular activation on twenty-four four-chamber heart meshes inclusive of His-Purkinje networks with left bundle branch block (LBBB). Leadless biventricular (BIV) pacing was simulated by adding an RV apical stimulus and an LV lateral wall stimulus (BIV-endo lateral) or targeting the left bundle (BIV-LBP), with an RV-LV delay set to 5 ms. To test effect of prolonged RV-LV delays and RV pacing location, the RV-LV delay was increased to 35 ms and/or the RV stimulus was moved to the RV septum. BIV-endo lateral pacing was less sensitive to increased RV-LV delays, while RV septal pacing worsened response compared to RV apical pacing, especially for long RV-LV delays. To investigate how left bundle capture affects response, we computed 90% BIV activation times (BIVAT-90) during BIV-LBP with selective and non-selective capture, and left bundle branch area pacing (LBBAP), simulated by pacing 1 cm below the left bundle. Non-selective LBP was comparable to selective LBP. LBBAP was worse than selective LBP (BIVAT-90: 54.2 ± 5.7 ms vs. 62.7 ± 6.5, p < 0.01), but it still significantly reduced activation times from baseline. Finally, we compared leadless LBP with RV pacing against optimal LBP delivery through a standard lead system by simulating BIV-LBP and selective LBP alone with and without optimized atrioventricular delay (AVD). Although LBP alone with optimized AVD was better than BIV-LBP, when AVD optimization was not possible BIV-LBP outperformed LBP alone, because the RV pacing stimulus shortened RV activation (BIVAT-90: 54.2 ± 5.7 ms vs. 66.9 ± 5.1 ms, p < 0.01). BIV-endo lateral pacing or LBP delivered through a leadless system could potentially become an alternative to standard CRT. RV-LV delay, RV lead location and type of left bundle capture affect leadless pacing efficacy and should be considered in future trial designs. Frontiers Media S.A. 2022-12-14 /pmc/articles/PMC9794756/ /pubmed/36589454 http://dx.doi.org/10.3389/fphys.2022.1049214 Text en Copyright © 2022 Strocchi, Wijesuriya, Elliott, Gillette, Neic, Mehta, Vigmond, Plank, Rinaldi and Niederer. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Strocchi, Marina Wijesuriya, Nadeev Elliott, Mark K. Gillette, Karli Neic, Aurel Mehta, Vishal Vigmond, Edward J. Plank, Gernot Rinaldi, Christopher A. Niederer, Steven A. Leadless biventricular left bundle and endocardial lateral wall pacing versus left bundle only pacing in left bundle branch block patients |
title | Leadless biventricular left bundle and endocardial lateral wall pacing versus left bundle only pacing in left bundle branch block patients |
title_full | Leadless biventricular left bundle and endocardial lateral wall pacing versus left bundle only pacing in left bundle branch block patients |
title_fullStr | Leadless biventricular left bundle and endocardial lateral wall pacing versus left bundle only pacing in left bundle branch block patients |
title_full_unstemmed | Leadless biventricular left bundle and endocardial lateral wall pacing versus left bundle only pacing in left bundle branch block patients |
title_short | Leadless biventricular left bundle and endocardial lateral wall pacing versus left bundle only pacing in left bundle branch block patients |
title_sort | leadless biventricular left bundle and endocardial lateral wall pacing versus left bundle only pacing in left bundle branch block patients |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9794756/ https://www.ncbi.nlm.nih.gov/pubmed/36589454 http://dx.doi.org/10.3389/fphys.2022.1049214 |
work_keys_str_mv | AT strocchimarina leadlessbiventricularleftbundleandendocardiallateralwallpacingversusleftbundleonlypacinginleftbundlebranchblockpatients AT wijesuriyanadeev leadlessbiventricularleftbundleandendocardiallateralwallpacingversusleftbundleonlypacinginleftbundlebranchblockpatients AT elliottmarkk leadlessbiventricularleftbundleandendocardiallateralwallpacingversusleftbundleonlypacinginleftbundlebranchblockpatients AT gillettekarli leadlessbiventricularleftbundleandendocardiallateralwallpacingversusleftbundleonlypacinginleftbundlebranchblockpatients AT neicaurel leadlessbiventricularleftbundleandendocardiallateralwallpacingversusleftbundleonlypacinginleftbundlebranchblockpatients AT mehtavishal leadlessbiventricularleftbundleandendocardiallateralwallpacingversusleftbundleonlypacinginleftbundlebranchblockpatients AT vigmondedwardj leadlessbiventricularleftbundleandendocardiallateralwallpacingversusleftbundleonlypacinginleftbundlebranchblockpatients AT plankgernot leadlessbiventricularleftbundleandendocardiallateralwallpacingversusleftbundleonlypacinginleftbundlebranchblockpatients AT rinaldichristophera leadlessbiventricularleftbundleandendocardiallateralwallpacingversusleftbundleonlypacinginleftbundlebranchblockpatients AT niedererstevena leadlessbiventricularleftbundleandendocardiallateralwallpacingversusleftbundleonlypacinginleftbundlebranchblockpatients |