Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study
INTRODUCTION: Dynamic Hip Screw fixation has shown to be equally effective compared to cephalomedullary nailing. The effectiveness of dynamic hip screw fixation for pertrochanteric fractures without using traction table is not well investigated. This study aimed to find out the mean tip apex distanc...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Journal of the Nepal Medical Association
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9795122/ https://www.ncbi.nlm.nih.gov/pubmed/36705110 http://dx.doi.org/10.31729/jnma.7766 |
_version_ | 1784860186355171328 |
---|---|
author | Regmi, Subhash Chaudhary, Rajesh Kumar Pradhan, Ishor Banskota, Bibek Joshi, Amit |
author_facet | Regmi, Subhash Chaudhary, Rajesh Kumar Pradhan, Ishor Banskota, Bibek Joshi, Amit |
author_sort | Regmi, Subhash |
collection | PubMed |
description | INTRODUCTION: Dynamic Hip Screw fixation has shown to be equally effective compared to cephalomedullary nailing. The effectiveness of dynamic hip screw fixation for pertrochanteric fractures without using traction table is not well investigated. This study aimed to find out the mean tip apex distance in patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table. METHODS: A descriptive cross-sectional study was conducted among patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table between 1 September 2021 and 30 June 2022 after getting approval from institutional review committee (Reference number: IRC-2021-08-23-02). All patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table were included in the study. Patients with pre-existing ipsilateral or contralateral hip deformity, contra-lateral hip prosthesis, bilateral hip fractures, and history of prior ipsilateral hip surgeries were excluded. Convenience sampling was done. Point estimate and 95% confidence interval were calculated. RESULTS: Among 45 patients, the mean tip apex distance was 20.45±6.13 mm (18.66-22.24 mm, 95% Confidence Interval). Among 45 patients, 24 (53.33%) were males and 21 (46.66%) were females. The average age of the participants was 67.75±21.33 years. CONCLUSIONS: The mean tip apex distance in patients undergoing dynamic hip Screw fixation for pertrochanteric fractures without using traction table was similar to that reported in other international studies. |
format | Online Article Text |
id | pubmed-9795122 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Journal of the Nepal Medical Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-97951222023-01-04 Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study Regmi, Subhash Chaudhary, Rajesh Kumar Pradhan, Ishor Banskota, Bibek Joshi, Amit JNMA J Nepal Med Assoc Original Article INTRODUCTION: Dynamic Hip Screw fixation has shown to be equally effective compared to cephalomedullary nailing. The effectiveness of dynamic hip screw fixation for pertrochanteric fractures without using traction table is not well investigated. This study aimed to find out the mean tip apex distance in patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table. METHODS: A descriptive cross-sectional study was conducted among patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table between 1 September 2021 and 30 June 2022 after getting approval from institutional review committee (Reference number: IRC-2021-08-23-02). All patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table were included in the study. Patients with pre-existing ipsilateral or contralateral hip deformity, contra-lateral hip prosthesis, bilateral hip fractures, and history of prior ipsilateral hip surgeries were excluded. Convenience sampling was done. Point estimate and 95% confidence interval were calculated. RESULTS: Among 45 patients, the mean tip apex distance was 20.45±6.13 mm (18.66-22.24 mm, 95% Confidence Interval). Among 45 patients, 24 (53.33%) were males and 21 (46.66%) were females. The average age of the participants was 67.75±21.33 years. CONCLUSIONS: The mean tip apex distance in patients undergoing dynamic hip Screw fixation for pertrochanteric fractures without using traction table was similar to that reported in other international studies. Journal of the Nepal Medical Association 2022-12 2022-12-31 /pmc/articles/PMC9795122/ /pubmed/36705110 http://dx.doi.org/10.31729/jnma.7766 Text en © The Author(s) 2018. https://creativecommons.org/licenses/by/4.0/This is an Open-Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Regmi, Subhash Chaudhary, Rajesh Kumar Pradhan, Ishor Banskota, Bibek Joshi, Amit Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study |
title | Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study |
title_full | Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study |
title_fullStr | Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study |
title_full_unstemmed | Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study |
title_short | Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study |
title_sort | mean tip apex distance in patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table: a descriptive cross-sectional study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9795122/ https://www.ncbi.nlm.nih.gov/pubmed/36705110 http://dx.doi.org/10.31729/jnma.7766 |
work_keys_str_mv | AT regmisubhash meantipapexdistanceinpatientsundergoingdynamichipscrewfixationforpertrochantericfractureswithoutusingtractiontableadescriptivecrosssectionalstudy AT chaudharyrajeshkumar meantipapexdistanceinpatientsundergoingdynamichipscrewfixationforpertrochantericfractureswithoutusingtractiontableadescriptivecrosssectionalstudy AT pradhanishor meantipapexdistanceinpatientsundergoingdynamichipscrewfixationforpertrochantericfractureswithoutusingtractiontableadescriptivecrosssectionalstudy AT banskotabibek meantipapexdistanceinpatientsundergoingdynamichipscrewfixationforpertrochantericfractureswithoutusingtractiontableadescriptivecrosssectionalstudy AT joshiamit meantipapexdistanceinpatientsundergoingdynamichipscrewfixationforpertrochantericfractureswithoutusingtractiontableadescriptivecrosssectionalstudy |