Cargando…

Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study

INTRODUCTION: Dynamic Hip Screw fixation has shown to be equally effective compared to cephalomedullary nailing. The effectiveness of dynamic hip screw fixation for pertrochanteric fractures without using traction table is not well investigated. This study aimed to find out the mean tip apex distanc...

Descripción completa

Detalles Bibliográficos
Autores principales: Regmi, Subhash, Chaudhary, Rajesh Kumar, Pradhan, Ishor, Banskota, Bibek, Joshi, Amit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Journal of the Nepal Medical Association 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9795122/
https://www.ncbi.nlm.nih.gov/pubmed/36705110
http://dx.doi.org/10.31729/jnma.7766
_version_ 1784860186355171328
author Regmi, Subhash
Chaudhary, Rajesh Kumar
Pradhan, Ishor
Banskota, Bibek
Joshi, Amit
author_facet Regmi, Subhash
Chaudhary, Rajesh Kumar
Pradhan, Ishor
Banskota, Bibek
Joshi, Amit
author_sort Regmi, Subhash
collection PubMed
description INTRODUCTION: Dynamic Hip Screw fixation has shown to be equally effective compared to cephalomedullary nailing. The effectiveness of dynamic hip screw fixation for pertrochanteric fractures without using traction table is not well investigated. This study aimed to find out the mean tip apex distance in patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table. METHODS: A descriptive cross-sectional study was conducted among patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table between 1 September 2021 and 30 June 2022 after getting approval from institutional review committee (Reference number: IRC-2021-08-23-02). All patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table were included in the study. Patients with pre-existing ipsilateral or contralateral hip deformity, contra-lateral hip prosthesis, bilateral hip fractures, and history of prior ipsilateral hip surgeries were excluded. Convenience sampling was done. Point estimate and 95% confidence interval were calculated. RESULTS: Among 45 patients, the mean tip apex distance was 20.45±6.13 mm (18.66-22.24 mm, 95% Confidence Interval). Among 45 patients, 24 (53.33%) were males and 21 (46.66%) were females. The average age of the participants was 67.75±21.33 years. CONCLUSIONS: The mean tip apex distance in patients undergoing dynamic hip Screw fixation for pertrochanteric fractures without using traction table was similar to that reported in other international studies.
format Online
Article
Text
id pubmed-9795122
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Journal of the Nepal Medical Association
record_format MEDLINE/PubMed
spelling pubmed-97951222023-01-04 Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study Regmi, Subhash Chaudhary, Rajesh Kumar Pradhan, Ishor Banskota, Bibek Joshi, Amit JNMA J Nepal Med Assoc Original Article INTRODUCTION: Dynamic Hip Screw fixation has shown to be equally effective compared to cephalomedullary nailing. The effectiveness of dynamic hip screw fixation for pertrochanteric fractures without using traction table is not well investigated. This study aimed to find out the mean tip apex distance in patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table. METHODS: A descriptive cross-sectional study was conducted among patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table between 1 September 2021 and 30 June 2022 after getting approval from institutional review committee (Reference number: IRC-2021-08-23-02). All patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table were included in the study. Patients with pre-existing ipsilateral or contralateral hip deformity, contra-lateral hip prosthesis, bilateral hip fractures, and history of prior ipsilateral hip surgeries were excluded. Convenience sampling was done. Point estimate and 95% confidence interval were calculated. RESULTS: Among 45 patients, the mean tip apex distance was 20.45±6.13 mm (18.66-22.24 mm, 95% Confidence Interval). Among 45 patients, 24 (53.33%) were males and 21 (46.66%) were females. The average age of the participants was 67.75±21.33 years. CONCLUSIONS: The mean tip apex distance in patients undergoing dynamic hip Screw fixation for pertrochanteric fractures without using traction table was similar to that reported in other international studies. Journal of the Nepal Medical Association 2022-12 2022-12-31 /pmc/articles/PMC9795122/ /pubmed/36705110 http://dx.doi.org/10.31729/jnma.7766 Text en © The Author(s) 2018. https://creativecommons.org/licenses/by/4.0/This is an Open-Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Regmi, Subhash
Chaudhary, Rajesh Kumar
Pradhan, Ishor
Banskota, Bibek
Joshi, Amit
Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study
title Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study
title_full Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study
title_fullStr Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study
title_full_unstemmed Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study
title_short Mean Tip Apex Distance in Patients undergoing Dynamic Hip Screw Fixation for Pertrochanteric Fractures without using Traction Table: A Descriptive Cross-sectional Study
title_sort mean tip apex distance in patients undergoing dynamic hip screw fixation for pertrochanteric fractures without using traction table: a descriptive cross-sectional study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9795122/
https://www.ncbi.nlm.nih.gov/pubmed/36705110
http://dx.doi.org/10.31729/jnma.7766
work_keys_str_mv AT regmisubhash meantipapexdistanceinpatientsundergoingdynamichipscrewfixationforpertrochantericfractureswithoutusingtractiontableadescriptivecrosssectionalstudy
AT chaudharyrajeshkumar meantipapexdistanceinpatientsundergoingdynamichipscrewfixationforpertrochantericfractureswithoutusingtractiontableadescriptivecrosssectionalstudy
AT pradhanishor meantipapexdistanceinpatientsundergoingdynamichipscrewfixationforpertrochantericfractureswithoutusingtractiontableadescriptivecrosssectionalstudy
AT banskotabibek meantipapexdistanceinpatientsundergoingdynamichipscrewfixationforpertrochantericfractureswithoutusingtractiontableadescriptivecrosssectionalstudy
AT joshiamit meantipapexdistanceinpatientsundergoingdynamichipscrewfixationforpertrochantericfractureswithoutusingtractiontableadescriptivecrosssectionalstudy