Time course of oversensing and impedance changes in developing implantable cardioverter-defibrillator lead fracture

BACKGROUND: Pace–sense conductors comprise a pacing coil to the tip electrode and cable to the ring-electrode. Implantable cardioverter-defibrillator (ICD) lead-monitoring diagnostics include pacing impedance (direct current resistance [DCR]) and measures of oversensing. How they change as fractures...

Descripción completa

Detalles Bibliográficos
Autores principales: Himes, Adam, Hoium, Scott, Swerdlow, Charles D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9795312/
https://www.ncbi.nlm.nih.gov/pubmed/36589919
http://dx.doi.org/10.1016/j.hroo.2022.09.014
_version_ 1784860232478883840
author Himes, Adam
Hoium, Scott
Swerdlow, Charles D.
author_facet Himes, Adam
Hoium, Scott
Swerdlow, Charles D.
author_sort Himes, Adam
collection PubMed
description BACKGROUND: Pace–sense conductors comprise a pacing coil to the tip electrode and cable to the ring-electrode. Implantable cardioverter-defibrillator (ICD) lead-monitoring diagnostics include pacing impedance (direct current resistance [DCR]) and measures of oversensing. How they change as fractures progress is unknown. OBJECTIVES: To characterize the relationship between oversensing, impedance, and structural changes in ICD leads developing pace–sense conductor fractures. METHODS: We performed bending tests on 39 leads connected to ICD generators in an electrolyte bath with simulated electrograms. DCR was recorded every 3 minutes; electrograms were telemetered continuously. Twenty-two leads were tested to develop partial or complete fracture criteria confirmed by imaging, using DCR or DCR variability measured by standard deviation (σ(DCR)). Results are reported for 17 other test leads. RESULTS: Initial oversensing occurred with partial pacing coil fracture vs complete ring cable fracture and correlated with bending-induced DCR peaks. These peaks were too small to be detected by clinical impedance measurements and were characterized by small increases in σ(DCR) (≥0.5 Ω). Impedance threshold alerts occurred at complete pacing coil fracture but only later for ring cable fractures. The oversensing alert triggered before device-detected ventricular fibrillation more frequently than impedance alerts (94% vs 17%; P = .00002). CONCLUSIONS: In conductor fracture, early oversensing corresponds to partial pacing coil fracture or complete ring cable fracture and correlates with transient bending-induced impedance increases, which are detected by impedance variability but too small to trigger clinical impedance alerts. This explains why clinical oversensing alerts provide more warning for device-detected ventricular fibrillation than impedance alerts and suggests how to improve impedance diagnostics based on short-term variability.
format Online
Article
Text
id pubmed-9795312
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-97953122022-12-29 Time course of oversensing and impedance changes in developing implantable cardioverter-defibrillator lead fracture Himes, Adam Hoium, Scott Swerdlow, Charles D. Heart Rhythm O2 Experimental BACKGROUND: Pace–sense conductors comprise a pacing coil to the tip electrode and cable to the ring-electrode. Implantable cardioverter-defibrillator (ICD) lead-monitoring diagnostics include pacing impedance (direct current resistance [DCR]) and measures of oversensing. How they change as fractures progress is unknown. OBJECTIVES: To characterize the relationship between oversensing, impedance, and structural changes in ICD leads developing pace–sense conductor fractures. METHODS: We performed bending tests on 39 leads connected to ICD generators in an electrolyte bath with simulated electrograms. DCR was recorded every 3 minutes; electrograms were telemetered continuously. Twenty-two leads were tested to develop partial or complete fracture criteria confirmed by imaging, using DCR or DCR variability measured by standard deviation (σ(DCR)). Results are reported for 17 other test leads. RESULTS: Initial oversensing occurred with partial pacing coil fracture vs complete ring cable fracture and correlated with bending-induced DCR peaks. These peaks were too small to be detected by clinical impedance measurements and were characterized by small increases in σ(DCR) (≥0.5 Ω). Impedance threshold alerts occurred at complete pacing coil fracture but only later for ring cable fractures. The oversensing alert triggered before device-detected ventricular fibrillation more frequently than impedance alerts (94% vs 17%; P = .00002). CONCLUSIONS: In conductor fracture, early oversensing corresponds to partial pacing coil fracture or complete ring cable fracture and correlates with transient bending-induced impedance increases, which are detected by impedance variability but too small to trigger clinical impedance alerts. This explains why clinical oversensing alerts provide more warning for device-detected ventricular fibrillation than impedance alerts and suggests how to improve impedance diagnostics based on short-term variability. Elsevier 2022-09-21 /pmc/articles/PMC9795312/ /pubmed/36589919 http://dx.doi.org/10.1016/j.hroo.2022.09.014 Text en © 2022 Heart Rhythm Society. Published by Elsevier Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Experimental
Himes, Adam
Hoium, Scott
Swerdlow, Charles D.
Time course of oversensing and impedance changes in developing implantable cardioverter-defibrillator lead fracture
title Time course of oversensing and impedance changes in developing implantable cardioverter-defibrillator lead fracture
title_full Time course of oversensing and impedance changes in developing implantable cardioverter-defibrillator lead fracture
title_fullStr Time course of oversensing and impedance changes in developing implantable cardioverter-defibrillator lead fracture
title_full_unstemmed Time course of oversensing and impedance changes in developing implantable cardioverter-defibrillator lead fracture
title_short Time course of oversensing and impedance changes in developing implantable cardioverter-defibrillator lead fracture
title_sort time course of oversensing and impedance changes in developing implantable cardioverter-defibrillator lead fracture
topic Experimental
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9795312/
https://www.ncbi.nlm.nih.gov/pubmed/36589919
http://dx.doi.org/10.1016/j.hroo.2022.09.014
work_keys_str_mv AT himesadam timecourseofoversensingandimpedancechangesindevelopingimplantablecardioverterdefibrillatorleadfracture
AT hoiumscott timecourseofoversensingandimpedancechangesindevelopingimplantablecardioverterdefibrillatorleadfracture
AT swerdlowcharlesd timecourseofoversensingandimpedancechangesindevelopingimplantablecardioverterdefibrillatorleadfracture