Cargando…

Facilitation techniques to cross the interatrial septum with intracardiac echocardiography during left atrial appendage closure

OBJECTIVES: This study aimed to assess the rate of difficult interatrial septum (IAS) crossing with the intracardiac echocardiography (ICE) probe during percutaneous left atrial appendage (LAA) closure and to identify techniques that facilitate IAS crossing with the ICE probe. BACKGROUND: Percutaneo...

Descripción completa

Detalles Bibliográficos
Autores principales: Vanhaverbeke, Maarten, Nuyens, Philippe, Bieliauskas, Gintautas, Sondergaard, Lars, Vejlstrup, Niels, De Backer, Ole
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9796577/
https://www.ncbi.nlm.nih.gov/pubmed/35880854
http://dx.doi.org/10.1002/ccd.30348
_version_ 1784860517672681472
author Vanhaverbeke, Maarten
Nuyens, Philippe
Bieliauskas, Gintautas
Sondergaard, Lars
Vejlstrup, Niels
De Backer, Ole
author_facet Vanhaverbeke, Maarten
Nuyens, Philippe
Bieliauskas, Gintautas
Sondergaard, Lars
Vejlstrup, Niels
De Backer, Ole
author_sort Vanhaverbeke, Maarten
collection PubMed
description OBJECTIVES: This study aimed to assess the rate of difficult interatrial septum (IAS) crossing with the intracardiac echocardiography (ICE) probe during percutaneous left atrial appendage (LAA) closure and to identify techniques that facilitate IAS crossing with the ICE probe. BACKGROUND: Percutaneous LAA closure is increasingly performed by ICE guidance. Although such an approach omits the need for general anesthesia, crossing of the IAS with the ICE probe may sometimes be challenging. METHODS: All consecutive patients that underwent ICE‐guided percutaneous LAA closure with an Amplatzer Amulet (Abbott) or WatchmanFLX (Boston Scientific) at our center in the period 2018–2021 were included. Cases in which IAS crossing with ICE was difficult were identified and techniques used to facilitate IAS crossing were identified and listed. RESULTS: In 17 (5%) out of 354 cases, IAS crossing with the ICE probe was difficult and required use of additional techniques. Ultimately, IAS crossing was also successful in these 17 cases by using one of three possible facilitation techniques: the probing technique (12 cases), the double‐wire technique (3 cases), and the snaring technique (2 cases). In one case, the double‐wire technique was converted to the snaring technique, as crossing of the ICE probe remained challenging despite the use of two stiff guidewires. CONCLUSION: Crossing of the IAS with the ICE probe can be challenging in 5% of ICE‐guided percutaneous LAA closure procedures. Operators should be aware of possible facilitation techniques in challenging cases, as these show to be safe and effective.
format Online
Article
Text
id pubmed-9796577
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-97965772022-12-30 Facilitation techniques to cross the interatrial septum with intracardiac echocardiography during left atrial appendage closure Vanhaverbeke, Maarten Nuyens, Philippe Bieliauskas, Gintautas Sondergaard, Lars Vejlstrup, Niels De Backer, Ole Catheter Cardiovasc Interv Valvular and Structural Heart Diseases OBJECTIVES: This study aimed to assess the rate of difficult interatrial septum (IAS) crossing with the intracardiac echocardiography (ICE) probe during percutaneous left atrial appendage (LAA) closure and to identify techniques that facilitate IAS crossing with the ICE probe. BACKGROUND: Percutaneous LAA closure is increasingly performed by ICE guidance. Although such an approach omits the need for general anesthesia, crossing of the IAS with the ICE probe may sometimes be challenging. METHODS: All consecutive patients that underwent ICE‐guided percutaneous LAA closure with an Amplatzer Amulet (Abbott) or WatchmanFLX (Boston Scientific) at our center in the period 2018–2021 were included. Cases in which IAS crossing with ICE was difficult were identified and techniques used to facilitate IAS crossing were identified and listed. RESULTS: In 17 (5%) out of 354 cases, IAS crossing with the ICE probe was difficult and required use of additional techniques. Ultimately, IAS crossing was also successful in these 17 cases by using one of three possible facilitation techniques: the probing technique (12 cases), the double‐wire technique (3 cases), and the snaring technique (2 cases). In one case, the double‐wire technique was converted to the snaring technique, as crossing of the ICE probe remained challenging despite the use of two stiff guidewires. CONCLUSION: Crossing of the IAS with the ICE probe can be challenging in 5% of ICE‐guided percutaneous LAA closure procedures. Operators should be aware of possible facilitation techniques in challenging cases, as these show to be safe and effective. John Wiley and Sons Inc. 2022-07-26 2022-11-01 /pmc/articles/PMC9796577/ /pubmed/35880854 http://dx.doi.org/10.1002/ccd.30348 Text en © 2022 The Authors. Catheterization and Cardiovascular Interventions published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Valvular and Structural Heart Diseases
Vanhaverbeke, Maarten
Nuyens, Philippe
Bieliauskas, Gintautas
Sondergaard, Lars
Vejlstrup, Niels
De Backer, Ole
Facilitation techniques to cross the interatrial septum with intracardiac echocardiography during left atrial appendage closure
title Facilitation techniques to cross the interatrial septum with intracardiac echocardiography during left atrial appendage closure
title_full Facilitation techniques to cross the interatrial septum with intracardiac echocardiography during left atrial appendage closure
title_fullStr Facilitation techniques to cross the interatrial septum with intracardiac echocardiography during left atrial appendage closure
title_full_unstemmed Facilitation techniques to cross the interatrial septum with intracardiac echocardiography during left atrial appendage closure
title_short Facilitation techniques to cross the interatrial septum with intracardiac echocardiography during left atrial appendage closure
title_sort facilitation techniques to cross the interatrial septum with intracardiac echocardiography during left atrial appendage closure
topic Valvular and Structural Heart Diseases
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9796577/
https://www.ncbi.nlm.nih.gov/pubmed/35880854
http://dx.doi.org/10.1002/ccd.30348
work_keys_str_mv AT vanhaverbekemaarten facilitationtechniquestocrosstheinteratrialseptumwithintracardiacechocardiographyduringleftatrialappendageclosure
AT nuyensphilippe facilitationtechniquestocrosstheinteratrialseptumwithintracardiacechocardiographyduringleftatrialappendageclosure
AT bieliauskasgintautas facilitationtechniquestocrosstheinteratrialseptumwithintracardiacechocardiographyduringleftatrialappendageclosure
AT sondergaardlars facilitationtechniquestocrosstheinteratrialseptumwithintracardiacechocardiographyduringleftatrialappendageclosure
AT vejlstrupniels facilitationtechniquestocrosstheinteratrialseptumwithintracardiacechocardiographyduringleftatrialappendageclosure
AT debackerole facilitationtechniquestocrosstheinteratrialseptumwithintracardiacechocardiographyduringleftatrialappendageclosure