The effect of repeated freezing and thawing on the suture pull‐out strength in equine arytenoid and cricoid cartilages
OBJECTIVE: To assess the effect of repeated freezing and thawing on the suture pull‐out strength in arytenoid and cricoid cartilages subjected to the laryngoplasty (LP) procedure. STUDY DESIGN: Ex vivo experimental study. SAMPLE POPULATION: Ten grossly normal equine cadaveric larynges. METHODS: Bila...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley & Sons, Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9796672/ https://www.ncbi.nlm.nih.gov/pubmed/35815735 http://dx.doi.org/10.1111/vsu.13855 |
_version_ | 1784860539775614976 |
---|---|
author | Gray, Sarah M. Gutierrez‐Nibeyro, Santiago D. Horn, Gavin P. McCoy, Annette M. Schaeffer, David J. Stewart, Matt |
author_facet | Gray, Sarah M. Gutierrez‐Nibeyro, Santiago D. Horn, Gavin P. McCoy, Annette M. Schaeffer, David J. Stewart, Matt |
author_sort | Gray, Sarah M. |
collection | PubMed |
description | OBJECTIVE: To assess the effect of repeated freezing and thawing on the suture pull‐out strength in arytenoid and cricoid cartilages subjected to the laryngoplasty (LP) procedure. STUDY DESIGN: Ex vivo experimental study. SAMPLE POPULATION: Ten grossly normal equine cadaveric larynges. METHODS: Bilateral LP constructs were created using a standard LP technique. One hemilarynx was randomly allocated to the single freeze and thaw group and the other allocated to the repeated freeze and thaw (3 complete cycles) group. The suture ends of each LP construct were attached to a load frame and subjected to monotonic loading until construct failure. Mean load (N) and displacement (mm) at LP construct failure were compared between groups. RESULTS: All LP constructs failed by suture pull through the arytenoid cartilage. The mean load at failure was similar between groups (118.9 ± 25.5 N in the single freeze and thaw group and 113.4 ± 20.5 N in the repeated freeze and thaw group, P = .62). The mean displacement at failure was similar between groups (54.4 ± 15.1 mm in the single freeze and thaw group and 54.4 ± 15.4 mm in the repeated freeze and thaw group, P = .99). CONCLUSION: Repeated freezing and thawing did not affect the suture pullout strength of the arytenoid and cricoid cartilages. CLINICAL SIGNIFICANCE: Laryngeal specimens that have been subjected to repeated freezing and thawing can be utilized in the experimental evaluation of LP procedures because there is no alteration of the suture pull‐out strength of the relevant cartilages. |
format | Online Article Text |
id | pubmed-9796672 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | John Wiley & Sons, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-97966722023-01-04 The effect of repeated freezing and thawing on the suture pull‐out strength in equine arytenoid and cricoid cartilages Gray, Sarah M. Gutierrez‐Nibeyro, Santiago D. Horn, Gavin P. McCoy, Annette M. Schaeffer, David J. Stewart, Matt Vet Surg Clinical Research OBJECTIVE: To assess the effect of repeated freezing and thawing on the suture pull‐out strength in arytenoid and cricoid cartilages subjected to the laryngoplasty (LP) procedure. STUDY DESIGN: Ex vivo experimental study. SAMPLE POPULATION: Ten grossly normal equine cadaveric larynges. METHODS: Bilateral LP constructs were created using a standard LP technique. One hemilarynx was randomly allocated to the single freeze and thaw group and the other allocated to the repeated freeze and thaw (3 complete cycles) group. The suture ends of each LP construct were attached to a load frame and subjected to monotonic loading until construct failure. Mean load (N) and displacement (mm) at LP construct failure were compared between groups. RESULTS: All LP constructs failed by suture pull through the arytenoid cartilage. The mean load at failure was similar between groups (118.9 ± 25.5 N in the single freeze and thaw group and 113.4 ± 20.5 N in the repeated freeze and thaw group, P = .62). The mean displacement at failure was similar between groups (54.4 ± 15.1 mm in the single freeze and thaw group and 54.4 ± 15.4 mm in the repeated freeze and thaw group, P = .99). CONCLUSION: Repeated freezing and thawing did not affect the suture pullout strength of the arytenoid and cricoid cartilages. CLINICAL SIGNIFICANCE: Laryngeal specimens that have been subjected to repeated freezing and thawing can be utilized in the experimental evaluation of LP procedures because there is no alteration of the suture pull‐out strength of the relevant cartilages. John Wiley & Sons, Inc. 2022-07-11 2022-10 /pmc/articles/PMC9796672/ /pubmed/35815735 http://dx.doi.org/10.1111/vsu.13855 Text en © 2022 The Authors. Veterinary Surgery published by Wiley Periodicals LLC on behalf of American College of Veterinary Surgeons. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Clinical Research Gray, Sarah M. Gutierrez‐Nibeyro, Santiago D. Horn, Gavin P. McCoy, Annette M. Schaeffer, David J. Stewart, Matt The effect of repeated freezing and thawing on the suture pull‐out strength in equine arytenoid and cricoid cartilages |
title | The effect of repeated freezing and thawing on the suture pull‐out strength in equine arytenoid and cricoid cartilages |
title_full | The effect of repeated freezing and thawing on the suture pull‐out strength in equine arytenoid and cricoid cartilages |
title_fullStr | The effect of repeated freezing and thawing on the suture pull‐out strength in equine arytenoid and cricoid cartilages |
title_full_unstemmed | The effect of repeated freezing and thawing on the suture pull‐out strength in equine arytenoid and cricoid cartilages |
title_short | The effect of repeated freezing and thawing on the suture pull‐out strength in equine arytenoid and cricoid cartilages |
title_sort | effect of repeated freezing and thawing on the suture pull‐out strength in equine arytenoid and cricoid cartilages |
topic | Clinical Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9796672/ https://www.ncbi.nlm.nih.gov/pubmed/35815735 http://dx.doi.org/10.1111/vsu.13855 |
work_keys_str_mv | AT graysarahm theeffectofrepeatedfreezingandthawingonthesuturepulloutstrengthinequinearytenoidandcricoidcartilages AT gutierreznibeyrosantiagod theeffectofrepeatedfreezingandthawingonthesuturepulloutstrengthinequinearytenoidandcricoidcartilages AT horngavinp theeffectofrepeatedfreezingandthawingonthesuturepulloutstrengthinequinearytenoidandcricoidcartilages AT mccoyannettem theeffectofrepeatedfreezingandthawingonthesuturepulloutstrengthinequinearytenoidandcricoidcartilages AT schaefferdavidj theeffectofrepeatedfreezingandthawingonthesuturepulloutstrengthinequinearytenoidandcricoidcartilages AT stewartmatt theeffectofrepeatedfreezingandthawingonthesuturepulloutstrengthinequinearytenoidandcricoidcartilages AT graysarahm effectofrepeatedfreezingandthawingonthesuturepulloutstrengthinequinearytenoidandcricoidcartilages AT gutierreznibeyrosantiagod effectofrepeatedfreezingandthawingonthesuturepulloutstrengthinequinearytenoidandcricoidcartilages AT horngavinp effectofrepeatedfreezingandthawingonthesuturepulloutstrengthinequinearytenoidandcricoidcartilages AT mccoyannettem effectofrepeatedfreezingandthawingonthesuturepulloutstrengthinequinearytenoidandcricoidcartilages AT schaefferdavidj effectofrepeatedfreezingandthawingonthesuturepulloutstrengthinequinearytenoidandcricoidcartilages AT stewartmatt effectofrepeatedfreezingandthawingonthesuturepulloutstrengthinequinearytenoidandcricoidcartilages |