Cargando…
Evaluation of the Potential Risk of Analyzing Phosphopeptides with Easy-nLC 1200-Coupled Mass Spectrometers
[Image: see text] Liquid chromatography–mass spectrometry (LC–MS) is a major tool for the large-scale qualitative and/or quantitative analysis of protein phosphorylation in cells or tissues. The performance of LC is pivotal for the success of phosphoproteomics in both sensitivity and reproducibility...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2022
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9798504/ https://www.ncbi.nlm.nih.gov/pubmed/36591174 http://dx.doi.org/10.1021/acsomega.2c05616 |
_version_ | 1784860918248636416 |
---|---|
author | Duan, Xiaoxiao Zhang, Yuanya Huang, Xiahe Ma, Xiao Gao, Hui Wang, Yingchun |
author_facet | Duan, Xiaoxiao Zhang, Yuanya Huang, Xiahe Ma, Xiao Gao, Hui Wang, Yingchun |
author_sort | Duan, Xiaoxiao |
collection | PubMed |
description | [Image: see text] Liquid chromatography–mass spectrometry (LC–MS) is a major tool for the large-scale qualitative and/or quantitative analysis of protein phosphorylation in cells or tissues. The performance of LC is pivotal for the success of phosphoproteomics in both sensitivity and reproducibility. Here, we report that the widely used Easy-nLC 1200 has poor performance in analyzing phosphopeptides, particularly in terms of sensitivity and reproducibility, whereas its predecessor, Easy-nLC 1000, has a much better performance. Therefore, we suggest that Easy-nLC 1200 is not appropriate for LC–MS-based proteomics analysis for samples with a limited amount, particularly phosphopeptides from plants. |
format | Online Article Text |
id | pubmed-9798504 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-97985042022-12-30 Evaluation of the Potential Risk of Analyzing Phosphopeptides with Easy-nLC 1200-Coupled Mass Spectrometers Duan, Xiaoxiao Zhang, Yuanya Huang, Xiahe Ma, Xiao Gao, Hui Wang, Yingchun ACS Omega [Image: see text] Liquid chromatography–mass spectrometry (LC–MS) is a major tool for the large-scale qualitative and/or quantitative analysis of protein phosphorylation in cells or tissues. The performance of LC is pivotal for the success of phosphoproteomics in both sensitivity and reproducibility. Here, we report that the widely used Easy-nLC 1200 has poor performance in analyzing phosphopeptides, particularly in terms of sensitivity and reproducibility, whereas its predecessor, Easy-nLC 1000, has a much better performance. Therefore, we suggest that Easy-nLC 1200 is not appropriate for LC–MS-based proteomics analysis for samples with a limited amount, particularly phosphopeptides from plants. American Chemical Society 2022-12-14 /pmc/articles/PMC9798504/ /pubmed/36591174 http://dx.doi.org/10.1021/acsomega.2c05616 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Duan, Xiaoxiao Zhang, Yuanya Huang, Xiahe Ma, Xiao Gao, Hui Wang, Yingchun Evaluation of the Potential Risk of Analyzing Phosphopeptides with Easy-nLC 1200-Coupled Mass Spectrometers |
title | Evaluation of the Potential Risk of Analyzing Phosphopeptides
with Easy-nLC 1200-Coupled Mass Spectrometers |
title_full | Evaluation of the Potential Risk of Analyzing Phosphopeptides
with Easy-nLC 1200-Coupled Mass Spectrometers |
title_fullStr | Evaluation of the Potential Risk of Analyzing Phosphopeptides
with Easy-nLC 1200-Coupled Mass Spectrometers |
title_full_unstemmed | Evaluation of the Potential Risk of Analyzing Phosphopeptides
with Easy-nLC 1200-Coupled Mass Spectrometers |
title_short | Evaluation of the Potential Risk of Analyzing Phosphopeptides
with Easy-nLC 1200-Coupled Mass Spectrometers |
title_sort | evaluation of the potential risk of analyzing phosphopeptides
with easy-nlc 1200-coupled mass spectrometers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9798504/ https://www.ncbi.nlm.nih.gov/pubmed/36591174 http://dx.doi.org/10.1021/acsomega.2c05616 |
work_keys_str_mv | AT duanxiaoxiao evaluationofthepotentialriskofanalyzingphosphopeptideswitheasynlc1200coupledmassspectrometers AT zhangyuanya evaluationofthepotentialriskofanalyzingphosphopeptideswitheasynlc1200coupledmassspectrometers AT huangxiahe evaluationofthepotentialriskofanalyzingphosphopeptideswitheasynlc1200coupledmassspectrometers AT maxiao evaluationofthepotentialriskofanalyzingphosphopeptideswitheasynlc1200coupledmassspectrometers AT gaohui evaluationofthepotentialriskofanalyzingphosphopeptideswitheasynlc1200coupledmassspectrometers AT wangyingchun evaluationofthepotentialriskofanalyzingphosphopeptideswitheasynlc1200coupledmassspectrometers |