Cargando…
A novel method to calculate compliance and airway resistance in ventilated patients
BACKGROUND: The respiratory system’s static compliance (C(rs)) and airway resistance (R(rs)) are measured during an end-inspiratory hold on volume-controlled ventilation (static method). A numerical algorithm is presented to calculate C(rs) and R(rs) during volume-controlled ventilation on a breath-...
Autor principal: | Gutierrez, Guillermo |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9800666/ https://www.ncbi.nlm.nih.gov/pubmed/36581716 http://dx.doi.org/10.1186/s40635-022-00483-2 |
Ejemplares similares
-
Impact of ketamine on dynamic compliance and airway resistance of sedated and mechanically ventilated ICU patients
por: Elamin, E
Publicado: (2009) -
Airway Resistance and Respiratory Compliance in Children with Acute Viral Bronchiolitis Requiring Mechanical Ventilation Support
por: Andreolio, Cinara, et al.
Publicado: (2021) -
Automatic detection of patient-ventilator asynchrony by spectral analysis of airway flow
por: Gutierrez, Guillermo, et al.
Publicado: (2011) -
Effect of endotracheal tube size on airway resistance and dynamic lung compliance
por: Li, Yiming, et al.
Publicado: (2022) -
Dynamic compliance in flow-controlled ventilation
por: Enk, Dietmar, et al.
Publicado: (2021)