Cargando…

Bland–Altman Plot: Agreement Between Ultrasound-measured Placenta Thickness and Other Biometric Parameters in the Determination of Gestational Age

PURPOSE: The aim of this article is to evaluate the agreement of placenta thickness (PT) with other foetal biometric parameters in the determination of gestational age (GA) in normal singleton foetuses. MATERIALS AND METHODS: The study was a cross-sectional descriptive study conducted among 406 cons...

Descripción completa

Detalles Bibliográficos
Autores principales: Olaleye, Omolara Adepate, Olatunji, Olubunmi O., Jimoh, Kamaldeen O., Olaleye, Abiola O.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9802599/
https://www.ncbi.nlm.nih.gov/pubmed/36590778
http://dx.doi.org/10.4103/jwas.jwas_165_22
_version_ 1784861709906739200
author Olaleye, Omolara Adepate
Olatunji, Olubunmi O.
Jimoh, Kamaldeen O.
Olaleye, Abiola O.
author_facet Olaleye, Omolara Adepate
Olatunji, Olubunmi O.
Jimoh, Kamaldeen O.
Olaleye, Abiola O.
author_sort Olaleye, Omolara Adepate
collection PubMed
description PURPOSE: The aim of this article is to evaluate the agreement of placenta thickness (PT) with other foetal biometric parameters in the determination of gestational age (GA) in normal singleton foetuses. MATERIALS AND METHODS: The study was a cross-sectional descriptive study conducted among 406 consecutively recruited pregnant women with singleton foetuses at 15–40 weeks of gestation at the National Hospital, Abuja, Nigeria from October to December 2019. Biparietal diameter (BPD), femur length (FL), head circumference (HC), abdominal circumference (AC), and PT were measured using standard measurement protocols. Bland and Altman (BA) plots were used to compare PT and other foetal biometric parameters. The significant statistical level was determined at a critical value of P < 0.05. RESULTS: The mean age of study participants was 31.8 ± 4.8 years. The BA plot of PT and HC demonstrated a normal distribution; the mean difference was around zero (3.968) and 95% of the measurements fell within 2SD of the mean. The BA plot of HC and AC measurements also showed that the 95% limits of agreement for differences fell within 10% of the mean of the measurements (-4.236 to 15.987 with a mean difference of 5.876), indicating good agreement between the two pairs of variables. However, BA plots between PT and BPD as well as PT and FL showed no agreement. CONCLUSION: This study indicates that there is good agreement or comparability between PT and HC measurements as well as between PT and AC measurements. Hence, either HC or AC measurements may be interchangeable with PT measurements in the ultrasound determination of GA. However, PT measurements did not agree well with BPD and FL measurements, respectively.
format Online
Article
Text
id pubmed-9802599
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-98025992022-12-31 Bland–Altman Plot: Agreement Between Ultrasound-measured Placenta Thickness and Other Biometric Parameters in the Determination of Gestational Age Olaleye, Omolara Adepate Olatunji, Olubunmi O. Jimoh, Kamaldeen O. Olaleye, Abiola O. J West Afr Coll Surg Original Article PURPOSE: The aim of this article is to evaluate the agreement of placenta thickness (PT) with other foetal biometric parameters in the determination of gestational age (GA) in normal singleton foetuses. MATERIALS AND METHODS: The study was a cross-sectional descriptive study conducted among 406 consecutively recruited pregnant women with singleton foetuses at 15–40 weeks of gestation at the National Hospital, Abuja, Nigeria from October to December 2019. Biparietal diameter (BPD), femur length (FL), head circumference (HC), abdominal circumference (AC), and PT were measured using standard measurement protocols. Bland and Altman (BA) plots were used to compare PT and other foetal biometric parameters. The significant statistical level was determined at a critical value of P < 0.05. RESULTS: The mean age of study participants was 31.8 ± 4.8 years. The BA plot of PT and HC demonstrated a normal distribution; the mean difference was around zero (3.968) and 95% of the measurements fell within 2SD of the mean. The BA plot of HC and AC measurements also showed that the 95% limits of agreement for differences fell within 10% of the mean of the measurements (-4.236 to 15.987 with a mean difference of 5.876), indicating good agreement between the two pairs of variables. However, BA plots between PT and BPD as well as PT and FL showed no agreement. CONCLUSION: This study indicates that there is good agreement or comparability between PT and HC measurements as well as between PT and AC measurements. Hence, either HC or AC measurements may be interchangeable with PT measurements in the ultrasound determination of GA. However, PT measurements did not agree well with BPD and FL measurements, respectively. Wolters Kluwer - Medknow 2022 2022-11-23 /pmc/articles/PMC9802599/ /pubmed/36590778 http://dx.doi.org/10.4103/jwas.jwas_165_22 Text en Copyright: © 2022 Journal of the West African College of Surgeons https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Olaleye, Omolara Adepate
Olatunji, Olubunmi O.
Jimoh, Kamaldeen O.
Olaleye, Abiola O.
Bland–Altman Plot: Agreement Between Ultrasound-measured Placenta Thickness and Other Biometric Parameters in the Determination of Gestational Age
title Bland–Altman Plot: Agreement Between Ultrasound-measured Placenta Thickness and Other Biometric Parameters in the Determination of Gestational Age
title_full Bland–Altman Plot: Agreement Between Ultrasound-measured Placenta Thickness and Other Biometric Parameters in the Determination of Gestational Age
title_fullStr Bland–Altman Plot: Agreement Between Ultrasound-measured Placenta Thickness and Other Biometric Parameters in the Determination of Gestational Age
title_full_unstemmed Bland–Altman Plot: Agreement Between Ultrasound-measured Placenta Thickness and Other Biometric Parameters in the Determination of Gestational Age
title_short Bland–Altman Plot: Agreement Between Ultrasound-measured Placenta Thickness and Other Biometric Parameters in the Determination of Gestational Age
title_sort bland–altman plot: agreement between ultrasound-measured placenta thickness and other biometric parameters in the determination of gestational age
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9802599/
https://www.ncbi.nlm.nih.gov/pubmed/36590778
http://dx.doi.org/10.4103/jwas.jwas_165_22
work_keys_str_mv AT olaleyeomolaraadepate blandaltmanplotagreementbetweenultrasoundmeasuredplacentathicknessandotherbiometricparametersinthedeterminationofgestationalage
AT olatunjiolubunmio blandaltmanplotagreementbetweenultrasoundmeasuredplacentathicknessandotherbiometricparametersinthedeterminationofgestationalage
AT jimohkamaldeeno blandaltmanplotagreementbetweenultrasoundmeasuredplacentathicknessandotherbiometricparametersinthedeterminationofgestationalage
AT olaleyeabiolao blandaltmanplotagreementbetweenultrasoundmeasuredplacentathicknessandotherbiometricparametersinthedeterminationofgestationalage