Bi-Directional Axial Transmission measurements applied in a clinical environment

Accurate measurement of cortical bone parameters may improve fracture risk assessment and help clinicians on the best treatment strategy. Patients at risk of fracture are currently detected using the current X-Ray gold standard DXA (Dual XRay Absorptiometry). Different alternatives, such as 3D X-Ray...

Descripción completa

Detalles Bibliográficos
Autores principales: Minonzio, Jean-Gabriel, Ramiandrisoa, Donatien, Schneider, Johannes, Kohut, Eva, Streichhahn, Melanie, Stervbo, Ulrik, Wirth, Rainer, Westhoff, Timm Henning, Raum, Kay, Babel, Nina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9803229/
https://www.ncbi.nlm.nih.gov/pubmed/36584002
http://dx.doi.org/10.1371/journal.pone.0277831
_version_ 1784861836316770304
author Minonzio, Jean-Gabriel
Ramiandrisoa, Donatien
Schneider, Johannes
Kohut, Eva
Streichhahn, Melanie
Stervbo, Ulrik
Wirth, Rainer
Westhoff, Timm Henning
Raum, Kay
Babel, Nina
author_facet Minonzio, Jean-Gabriel
Ramiandrisoa, Donatien
Schneider, Johannes
Kohut, Eva
Streichhahn, Melanie
Stervbo, Ulrik
Wirth, Rainer
Westhoff, Timm Henning
Raum, Kay
Babel, Nina
author_sort Minonzio, Jean-Gabriel
collection PubMed
description Accurate measurement of cortical bone parameters may improve fracture risk assessment and help clinicians on the best treatment strategy. Patients at risk of fracture are currently detected using the current X-Ray gold standard DXA (Dual XRay Absorptiometry). Different alternatives, such as 3D X-Rays, Magnetic Resonance Imaging or Quantitative Ultrasound (QUS) devices, have been proposed, the latter having advantages of being portable and sensitive to mechanical and geometrical properties. The objective of this cross-sectional study was to evaluate the performance of a Bi-Directional Axial Transmission (BDAT) device used by trained operators in a clinical environment with older subjects. The device, positioned at one-third distal radius, provides two velocities: VFAS (first arriving signal) and VA0 (first anti-symmetrical guided mode). Moreover, two parameters are obtained from an inverse approach: Ct.Th (cortical thickness) and Ct.Po (cortical porosity), along with their ratio Ct.Po/Ct.Th. The areal bone mineral density (aBMD) was obtained using DXA at the femur and spine. One hundred and six patients (81 women, 25 men) from Marien Hospital and St. Anna Hospital (Herne, Germany) were included in this study. Age ranged from 41 to 95 years, while body mass index (BMI) ranged from 16 to 47 kg.m(−2). Three groups were considered: 79 non-fractured patients (NF, 75±13years), 27 with non-traumatic fractures (F, 80±9years) including 14 patients with non-vertebral fractures (NVF, 84±7years). Weak to moderate significant Spearman correlations (R ranging from 0.23 to 0.53, p < 0.05) were found between ultrasound parameters and age, BMI. Using multivariate Partial Least Square discrimination analyses with Leave-One-Out Cross-Validation (PLS-LOOCV), we found the combination of VFAS and the ratio Ct.Po/Ct.Th to be predictive for all non traumatic fractures (F) with the odds ratio (OR) equals to 2.5 [1.6-3.4] and the area under the ROC curve (AUC) equal to 0.63 [0.62-0.65]. For the group NVF, combination of four parameters VA0. Ct.Th, Ct.Po and Ct.Po/Ct.Po, along with age provides a discrimination model with OR and AUC equals to 7.5 [6.0-9.1] and 0.75 [0.73-0.76]. When restricted to a smaller population (87 patients) common to both BDAT and DXA, BDAT ORs and AUCs are comparable or slightly higher to values obtained with DXA. The fracture risk assessment by BDAT method in older patients, in a clinical setting, suggests the benefit of the affordable and transportable device for the routine use.
format Online
Article
Text
id pubmed-9803229
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-98032292022-12-31 Bi-Directional Axial Transmission measurements applied in a clinical environment Minonzio, Jean-Gabriel Ramiandrisoa, Donatien Schneider, Johannes Kohut, Eva Streichhahn, Melanie Stervbo, Ulrik Wirth, Rainer Westhoff, Timm Henning Raum, Kay Babel, Nina PLoS One Research Article Accurate measurement of cortical bone parameters may improve fracture risk assessment and help clinicians on the best treatment strategy. Patients at risk of fracture are currently detected using the current X-Ray gold standard DXA (Dual XRay Absorptiometry). Different alternatives, such as 3D X-Rays, Magnetic Resonance Imaging or Quantitative Ultrasound (QUS) devices, have been proposed, the latter having advantages of being portable and sensitive to mechanical and geometrical properties. The objective of this cross-sectional study was to evaluate the performance of a Bi-Directional Axial Transmission (BDAT) device used by trained operators in a clinical environment with older subjects. The device, positioned at one-third distal radius, provides two velocities: VFAS (first arriving signal) and VA0 (first anti-symmetrical guided mode). Moreover, two parameters are obtained from an inverse approach: Ct.Th (cortical thickness) and Ct.Po (cortical porosity), along with their ratio Ct.Po/Ct.Th. The areal bone mineral density (aBMD) was obtained using DXA at the femur and spine. One hundred and six patients (81 women, 25 men) from Marien Hospital and St. Anna Hospital (Herne, Germany) were included in this study. Age ranged from 41 to 95 years, while body mass index (BMI) ranged from 16 to 47 kg.m(−2). Three groups were considered: 79 non-fractured patients (NF, 75±13years), 27 with non-traumatic fractures (F, 80±9years) including 14 patients with non-vertebral fractures (NVF, 84±7years). Weak to moderate significant Spearman correlations (R ranging from 0.23 to 0.53, p < 0.05) were found between ultrasound parameters and age, BMI. Using multivariate Partial Least Square discrimination analyses with Leave-One-Out Cross-Validation (PLS-LOOCV), we found the combination of VFAS and the ratio Ct.Po/Ct.Th to be predictive for all non traumatic fractures (F) with the odds ratio (OR) equals to 2.5 [1.6-3.4] and the area under the ROC curve (AUC) equal to 0.63 [0.62-0.65]. For the group NVF, combination of four parameters VA0. Ct.Th, Ct.Po and Ct.Po/Ct.Po, along with age provides a discrimination model with OR and AUC equals to 7.5 [6.0-9.1] and 0.75 [0.73-0.76]. When restricted to a smaller population (87 patients) common to both BDAT and DXA, BDAT ORs and AUCs are comparable or slightly higher to values obtained with DXA. The fracture risk assessment by BDAT method in older patients, in a clinical setting, suggests the benefit of the affordable and transportable device for the routine use. Public Library of Science 2022-12-30 /pmc/articles/PMC9803229/ /pubmed/36584002 http://dx.doi.org/10.1371/journal.pone.0277831 Text en © 2022 Minonzio et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Minonzio, Jean-Gabriel
Ramiandrisoa, Donatien
Schneider, Johannes
Kohut, Eva
Streichhahn, Melanie
Stervbo, Ulrik
Wirth, Rainer
Westhoff, Timm Henning
Raum, Kay
Babel, Nina
Bi-Directional Axial Transmission measurements applied in a clinical environment
title Bi-Directional Axial Transmission measurements applied in a clinical environment
title_full Bi-Directional Axial Transmission measurements applied in a clinical environment
title_fullStr Bi-Directional Axial Transmission measurements applied in a clinical environment
title_full_unstemmed Bi-Directional Axial Transmission measurements applied in a clinical environment
title_short Bi-Directional Axial Transmission measurements applied in a clinical environment
title_sort bi-directional axial transmission measurements applied in a clinical environment
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9803229/
https://www.ncbi.nlm.nih.gov/pubmed/36584002
http://dx.doi.org/10.1371/journal.pone.0277831
work_keys_str_mv AT minonziojeangabriel bidirectionalaxialtransmissionmeasurementsappliedinaclinicalenvironment
AT ramiandrisoadonatien bidirectionalaxialtransmissionmeasurementsappliedinaclinicalenvironment
AT schneiderjohannes bidirectionalaxialtransmissionmeasurementsappliedinaclinicalenvironment
AT kohuteva bidirectionalaxialtransmissionmeasurementsappliedinaclinicalenvironment
AT streichhahnmelanie bidirectionalaxialtransmissionmeasurementsappliedinaclinicalenvironment
AT stervboulrik bidirectionalaxialtransmissionmeasurementsappliedinaclinicalenvironment
AT wirthrainer bidirectionalaxialtransmissionmeasurementsappliedinaclinicalenvironment
AT westhofftimmhenning bidirectionalaxialtransmissionmeasurementsappliedinaclinicalenvironment
AT raumkay bidirectionalaxialtransmissionmeasurementsappliedinaclinicalenvironment
AT babelnina bidirectionalaxialtransmissionmeasurementsappliedinaclinicalenvironment