Left ventricular ejection fraction by multigated acquisition scan using planar sodium iodide and cadmium-zinc-telluride cameras: a comparison with two-dimensional echocardiography

OBJECTIVE(S): This study was undertaken to compare the correlation and agreement between Modified Simpson’s method two-dimensional-echocardio-graphy (2D-echo) and rest multigated acquisition scan (MUGA) using both planar sodium iodide (pNaI) and cadmium-zinc-telluride (CZT) cameras to measure left v...

Descripción completa

Detalles Bibliográficos
Autores principales: Das, Gouri Kumar, NG, Chen Siew, Abdul Manap, Mahayuddin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mashhad University of Medical Sciences 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9803617/
https://www.ncbi.nlm.nih.gov/pubmed/36619189
http://dx.doi.org/10.22038/AOJNMB.2022.60392.1424
_version_ 1784861924598480896
author Das, Gouri Kumar
NG, Chen Siew
Abdul Manap, Mahayuddin
author_facet Das, Gouri Kumar
NG, Chen Siew
Abdul Manap, Mahayuddin
author_sort Das, Gouri Kumar
collection PubMed
description OBJECTIVE(S): This study was undertaken to compare the correlation and agreement between Modified Simpson’s method two-dimensional-echocardio-graphy (2D-echo) and rest multigated acquisition scan (MUGA) using both planar sodium iodide (pNaI) and cadmium-zinc-telluride (CZT) cameras to measure left ventricular ejection fraction (LVEF). METHODS: One hundred and nine breast cancer patients monitored for cardiotoxicity underwent 2D-echo, followed by pNaI and CZT MUGA scans on the same day. LVEF for CZT camera was processed using both automatic and manual processing methods, thus yielding four methods for the LVEF analysis. RESULTS: Significant correlation (p<0.01) was seen among all four methods, with varied correlation strengths. Moderate correlation was seen between 2D-echo and both pNaI (r=0.56) and CZT cameras (automatic r=0.54, manual r=0.56). Strong correlation was registered between pNaI and CZT camera (automatic r=0.72, manual r=0.71). Bland-Altman limits of agreement among the three scans were wide and suboptimal. The widest limits were -21.1 to +16.2 (37%) between 2D-echo and CZT auto-processing. CONCLUSION: Any one of the modalities can be used to measure LVEF, however, their results should not be used interchangeably. The same method of measurement is advised for serial scans.
format Online
Article
Text
id pubmed-9803617
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Mashhad University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-98036172023-01-07 Left ventricular ejection fraction by multigated acquisition scan using planar sodium iodide and cadmium-zinc-telluride cameras: a comparison with two-dimensional echocardiography Das, Gouri Kumar NG, Chen Siew Abdul Manap, Mahayuddin Asia Ocean J Nucl Med Biol Original Article OBJECTIVE(S): This study was undertaken to compare the correlation and agreement between Modified Simpson’s method two-dimensional-echocardio-graphy (2D-echo) and rest multigated acquisition scan (MUGA) using both planar sodium iodide (pNaI) and cadmium-zinc-telluride (CZT) cameras to measure left ventricular ejection fraction (LVEF). METHODS: One hundred and nine breast cancer patients monitored for cardiotoxicity underwent 2D-echo, followed by pNaI and CZT MUGA scans on the same day. LVEF for CZT camera was processed using both automatic and manual processing methods, thus yielding four methods for the LVEF analysis. RESULTS: Significant correlation (p<0.01) was seen among all four methods, with varied correlation strengths. Moderate correlation was seen between 2D-echo and both pNaI (r=0.56) and CZT cameras (automatic r=0.54, manual r=0.56). Strong correlation was registered between pNaI and CZT camera (automatic r=0.72, manual r=0.71). Bland-Altman limits of agreement among the three scans were wide and suboptimal. The widest limits were -21.1 to +16.2 (37%) between 2D-echo and CZT auto-processing. CONCLUSION: Any one of the modalities can be used to measure LVEF, however, their results should not be used interchangeably. The same method of measurement is advised for serial scans. Mashhad University of Medical Sciences 2023 /pmc/articles/PMC9803617/ /pubmed/36619189 http://dx.doi.org/10.22038/AOJNMB.2022.60392.1424 Text en © 2023 mums.ac.ir All rights reserved https://creativecommons.org/licenses/by/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/ (https://creativecommons.org/licenses/by/3.0/) ) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Das, Gouri Kumar
NG, Chen Siew
Abdul Manap, Mahayuddin
Left ventricular ejection fraction by multigated acquisition scan using planar sodium iodide and cadmium-zinc-telluride cameras: a comparison with two-dimensional echocardiography
title Left ventricular ejection fraction by multigated acquisition scan using planar sodium iodide and cadmium-zinc-telluride cameras: a comparison with two-dimensional echocardiography
title_full Left ventricular ejection fraction by multigated acquisition scan using planar sodium iodide and cadmium-zinc-telluride cameras: a comparison with two-dimensional echocardiography
title_fullStr Left ventricular ejection fraction by multigated acquisition scan using planar sodium iodide and cadmium-zinc-telluride cameras: a comparison with two-dimensional echocardiography
title_full_unstemmed Left ventricular ejection fraction by multigated acquisition scan using planar sodium iodide and cadmium-zinc-telluride cameras: a comparison with two-dimensional echocardiography
title_short Left ventricular ejection fraction by multigated acquisition scan using planar sodium iodide and cadmium-zinc-telluride cameras: a comparison with two-dimensional echocardiography
title_sort left ventricular ejection fraction by multigated acquisition scan using planar sodium iodide and cadmium-zinc-telluride cameras: a comparison with two-dimensional echocardiography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9803617/
https://www.ncbi.nlm.nih.gov/pubmed/36619189
http://dx.doi.org/10.22038/AOJNMB.2022.60392.1424
work_keys_str_mv AT dasgourikumar leftventricularejectionfractionbymultigatedacquisitionscanusingplanarsodiumiodideandcadmiumzinctelluridecamerasacomparisonwithtwodimensionalechocardiography
AT ngchensiew leftventricularejectionfractionbymultigatedacquisitionscanusingplanarsodiumiodideandcadmiumzinctelluridecamerasacomparisonwithtwodimensionalechocardiography
AT abdulmanapmahayuddin leftventricularejectionfractionbymultigatedacquisitionscanusingplanarsodiumiodideandcadmiumzinctelluridecamerasacomparisonwithtwodimensionalechocardiography