Cargando…

Impact of implant thread design on insertion torque and osseointegration: a preclinical model

BACKGROUND: Successful osseointegration of endosteal dental implants has been attributed to implant design, including the macro-, micro- and nano- geometric properties. Based on current literature pertaining to implant design, the resultant cellular and bone healing response is unknown when the thre...

Descripción completa

Detalles Bibliográficos
Autores principales: Benalcázar-Jalkh, Ernesto B, Nayak, Vasudev Vivekanand, Gory, Christina, Marquez-Guzman, Andres, Bergamo, Edmara TP, Tovar, Nick, Coelho, Paulo G, Bonfante, Estevam A, Witek, Lukasz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9805329/
https://www.ncbi.nlm.nih.gov/pubmed/36173722
http://dx.doi.org/10.4317/medoral.25576
_version_ 1784862315281121280
author Benalcázar-Jalkh, Ernesto B
Nayak, Vasudev Vivekanand
Gory, Christina
Marquez-Guzman, Andres
Bergamo, Edmara TP
Tovar, Nick
Coelho, Paulo G
Bonfante, Estevam A
Witek, Lukasz
author_facet Benalcázar-Jalkh, Ernesto B
Nayak, Vasudev Vivekanand
Gory, Christina
Marquez-Guzman, Andres
Bergamo, Edmara TP
Tovar, Nick
Coelho, Paulo G
Bonfante, Estevam A
Witek, Lukasz
author_sort Benalcázar-Jalkh, Ernesto B
collection PubMed
description BACKGROUND: Successful osseointegration of endosteal dental implants has been attributed to implant design, including the macro-, micro- and nano- geometric properties. Based on current literature pertaining to implant design, the resultant cellular and bone healing response is unknown when the thread thickness of the implants is increased, resulting in an increased contact area in implants designed with healing chambers. The aim of this study was to evaluate the effect of two implant designs with different thread profiles on the osseointegration parameters and implant stability at 3- and 6-weeks in vivo using a well-established preclinical dog model. MATERIAL AND METHODS: A total of 48 type V Ti alloy implants were divided in two groups according to their thread design (D1= +0.1x/mm and D2= +0.15x/mm) and placed in an interpolated fashion into the radii of six beagles. Insertion torque was measured at time of placement, radii were extracted for histological processing following 3- and 6-week healing intervals. Histologic and histomorphometric analyses were performed in terms of bone to implant contact (%BIC) and bone area fraction occupancy within implant threads (%BAFO). Statistical analyses were performed through a linear mixed model with fixed factors of time and implant thread design. RESULTS: Surface roughness analysis demonstrated no significant differences in Sa and Sq between D1 and D2 implant designs, which confirmed that both implant designs were homogenous except for their respective thread profiles. For insertion torque, statistically significant lower values were recorded for D1 in comparison to D2 (59.6 ± 11.1 and 78.9 ± 10.1 N⋅cm, respectively). Furthermore, there were no significant differences with respect to histological analysis and histomorphometric parameters, between D1 and D2 at both time points. CONCLUSIONS: Both thread profiles presented equivalent potential to successfully osseointegrate in the osteotomies, with D2 yielding higher mechanical retention upon placement without detrimental bone resorption. Key words:Thread design, dental implants, osseointegration, implant stability, microgeometry.
format Online
Article
Text
id pubmed-9805329
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Medicina Oral S.L.
record_format MEDLINE/PubMed
spelling pubmed-98053292023-01-12 Impact of implant thread design on insertion torque and osseointegration: a preclinical model Benalcázar-Jalkh, Ernesto B Nayak, Vasudev Vivekanand Gory, Christina Marquez-Guzman, Andres Bergamo, Edmara TP Tovar, Nick Coelho, Paulo G Bonfante, Estevam A Witek, Lukasz Med Oral Patol Oral Cir Bucal Research BACKGROUND: Successful osseointegration of endosteal dental implants has been attributed to implant design, including the macro-, micro- and nano- geometric properties. Based on current literature pertaining to implant design, the resultant cellular and bone healing response is unknown when the thread thickness of the implants is increased, resulting in an increased contact area in implants designed with healing chambers. The aim of this study was to evaluate the effect of two implant designs with different thread profiles on the osseointegration parameters and implant stability at 3- and 6-weeks in vivo using a well-established preclinical dog model. MATERIAL AND METHODS: A total of 48 type V Ti alloy implants were divided in two groups according to their thread design (D1= +0.1x/mm and D2= +0.15x/mm) and placed in an interpolated fashion into the radii of six beagles. Insertion torque was measured at time of placement, radii were extracted for histological processing following 3- and 6-week healing intervals. Histologic and histomorphometric analyses were performed in terms of bone to implant contact (%BIC) and bone area fraction occupancy within implant threads (%BAFO). Statistical analyses were performed through a linear mixed model with fixed factors of time and implant thread design. RESULTS: Surface roughness analysis demonstrated no significant differences in Sa and Sq between D1 and D2 implant designs, which confirmed that both implant designs were homogenous except for their respective thread profiles. For insertion torque, statistically significant lower values were recorded for D1 in comparison to D2 (59.6 ± 11.1 and 78.9 ± 10.1 N⋅cm, respectively). Furthermore, there were no significant differences with respect to histological analysis and histomorphometric parameters, between D1 and D2 at both time points. CONCLUSIONS: Both thread profiles presented equivalent potential to successfully osseointegrate in the osteotomies, with D2 yielding higher mechanical retention upon placement without detrimental bone resorption. Key words:Thread design, dental implants, osseointegration, implant stability, microgeometry. Medicina Oral S.L. 2023-01 2022-09-29 /pmc/articles/PMC9805329/ /pubmed/36173722 http://dx.doi.org/10.4317/medoral.25576 Text en Copyright: © 2023 Medicina Oral S.L. https://creativecommons.org/licenses/by/2.5/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Benalcázar-Jalkh, Ernesto B
Nayak, Vasudev Vivekanand
Gory, Christina
Marquez-Guzman, Andres
Bergamo, Edmara TP
Tovar, Nick
Coelho, Paulo G
Bonfante, Estevam A
Witek, Lukasz
Impact of implant thread design on insertion torque and osseointegration: a preclinical model
title Impact of implant thread design on insertion torque and osseointegration: a preclinical model
title_full Impact of implant thread design on insertion torque and osseointegration: a preclinical model
title_fullStr Impact of implant thread design on insertion torque and osseointegration: a preclinical model
title_full_unstemmed Impact of implant thread design on insertion torque and osseointegration: a preclinical model
title_short Impact of implant thread design on insertion torque and osseointegration: a preclinical model
title_sort impact of implant thread design on insertion torque and osseointegration: a preclinical model
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9805329/
https://www.ncbi.nlm.nih.gov/pubmed/36173722
http://dx.doi.org/10.4317/medoral.25576
work_keys_str_mv AT benalcazarjalkhernestob impactofimplantthreaddesignoninsertiontorqueandosseointegrationapreclinicalmodel
AT nayakvasudevvivekanand impactofimplantthreaddesignoninsertiontorqueandosseointegrationapreclinicalmodel
AT gorychristina impactofimplantthreaddesignoninsertiontorqueandosseointegrationapreclinicalmodel
AT marquezguzmanandres impactofimplantthreaddesignoninsertiontorqueandosseointegrationapreclinicalmodel
AT bergamoedmaratp impactofimplantthreaddesignoninsertiontorqueandosseointegrationapreclinicalmodel
AT tovarnick impactofimplantthreaddesignoninsertiontorqueandosseointegrationapreclinicalmodel
AT coelhopaulog impactofimplantthreaddesignoninsertiontorqueandosseointegrationapreclinicalmodel
AT bonfanteestevama impactofimplantthreaddesignoninsertiontorqueandosseointegrationapreclinicalmodel
AT witeklukasz impactofimplantthreaddesignoninsertiontorqueandosseointegrationapreclinicalmodel