Partial lung lobectomy with the Caiman(®) Seal & Cut device in a dog with spontaneous pneumothorax: Case report
BACKGROUND: Spontaneous pneumothorax in dogs is characterized by an accumulation of air in the interpleural space without underlying trauma and consecutive acute onset of respiratory distress. Underlying causes for spontaneous pneumothorax vary with ruptured bullae being one of the main causes. Trea...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Faculty of Veterinary Medicine
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9805754/ https://www.ncbi.nlm.nih.gov/pubmed/36650868 http://dx.doi.org/10.5455/OVJ.2022.v12.i6.17 |
_version_ | 1784862398508695552 |
---|---|
author | Zobe, Anne Rohwedder, Thomas Böttcher, Peter |
author_facet | Zobe, Anne Rohwedder, Thomas Böttcher, Peter |
author_sort | Zobe, Anne |
collection | PubMed |
description | BACKGROUND: Spontaneous pneumothorax in dogs is characterized by an accumulation of air in the interpleural space without underlying trauma and consecutive acute onset of respiratory distress. Underlying causes for spontaneous pneumothorax vary with ruptured bullae being one of the main causes. Treatment after initial stabilization often requires partial or complete surgical resection of affected lung lobes. Partial lung lobectomy can be performed with stapling devices or sealing devices for example, by different surgical approaches including video-assisted thoracoscopic surgery. However, inter-thoracic surgery in small-sized dogs using either of the techniques is challenging. CASE DESCRIPTION: A 12-year-old Shih Tzu was presented with spontaneous pneumothorax. Further diagnostics with computed tomography and intercostal thoracoscopy revealed a bulla in the right middle lung lobe. Partial lung lobectomy (2.5 × 2.5 × 2 cm) of the respective lung lobe was performed by an intercostal approach using the Caiman(®) 5 Seal & Cut sealing device. The Caiman(®) 5 Seal & Cut device allowed quick and safe partial lung lobectomy in the treatment of spontaneous pneumothorax without intra- or post-operative complications. The dog was discharged 2 days after surgery in good clinical condition. This report demonstrates the in-vivo efficacy and safety of the Caiman(®) 5 Seal & Cut sealing device for partial lung lobectomy in a small breed dog. CONCLUSION: Using the Caiman(®) 5 Seal & Cut device lung tissue could be resected without intra- or post-operative complications in a small breed dog. This case may emphasize the use of the device in fully video-assisted thoracoscopic surgery also in small-sized patients. |
format | Online Article Text |
id | pubmed-9805754 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Faculty of Veterinary Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-98057542023-01-16 Partial lung lobectomy with the Caiman(®) Seal & Cut device in a dog with spontaneous pneumothorax: Case report Zobe, Anne Rohwedder, Thomas Böttcher, Peter Open Vet J Review Article BACKGROUND: Spontaneous pneumothorax in dogs is characterized by an accumulation of air in the interpleural space without underlying trauma and consecutive acute onset of respiratory distress. Underlying causes for spontaneous pneumothorax vary with ruptured bullae being one of the main causes. Treatment after initial stabilization often requires partial or complete surgical resection of affected lung lobes. Partial lung lobectomy can be performed with stapling devices or sealing devices for example, by different surgical approaches including video-assisted thoracoscopic surgery. However, inter-thoracic surgery in small-sized dogs using either of the techniques is challenging. CASE DESCRIPTION: A 12-year-old Shih Tzu was presented with spontaneous pneumothorax. Further diagnostics with computed tomography and intercostal thoracoscopy revealed a bulla in the right middle lung lobe. Partial lung lobectomy (2.5 × 2.5 × 2 cm) of the respective lung lobe was performed by an intercostal approach using the Caiman(®) 5 Seal & Cut sealing device. The Caiman(®) 5 Seal & Cut device allowed quick and safe partial lung lobectomy in the treatment of spontaneous pneumothorax without intra- or post-operative complications. The dog was discharged 2 days after surgery in good clinical condition. This report demonstrates the in-vivo efficacy and safety of the Caiman(®) 5 Seal & Cut sealing device for partial lung lobectomy in a small breed dog. CONCLUSION: Using the Caiman(®) 5 Seal & Cut device lung tissue could be resected without intra- or post-operative complications in a small breed dog. This case may emphasize the use of the device in fully video-assisted thoracoscopic surgery also in small-sized patients. Faculty of Veterinary Medicine 2022 2022-12-01 /pmc/articles/PMC9805754/ /pubmed/36650868 http://dx.doi.org/10.5455/OVJ.2022.v12.i6.17 Text en https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Article Zobe, Anne Rohwedder, Thomas Böttcher, Peter Partial lung lobectomy with the Caiman(®) Seal & Cut device in a dog with spontaneous pneumothorax: Case report |
title | Partial lung lobectomy with the Caiman(®) Seal & Cut device in a dog with spontaneous pneumothorax: Case report |
title_full | Partial lung lobectomy with the Caiman(®) Seal & Cut device in a dog with spontaneous pneumothorax: Case report |
title_fullStr | Partial lung lobectomy with the Caiman(®) Seal & Cut device in a dog with spontaneous pneumothorax: Case report |
title_full_unstemmed | Partial lung lobectomy with the Caiman(®) Seal & Cut device in a dog with spontaneous pneumothorax: Case report |
title_short | Partial lung lobectomy with the Caiman(®) Seal & Cut device in a dog with spontaneous pneumothorax: Case report |
title_sort | partial lung lobectomy with the caiman(®) seal & cut device in a dog with spontaneous pneumothorax: case report |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9805754/ https://www.ncbi.nlm.nih.gov/pubmed/36650868 http://dx.doi.org/10.5455/OVJ.2022.v12.i6.17 |
work_keys_str_mv | AT zobeanne partiallunglobectomywiththecaimansealcutdeviceinadogwithspontaneouspneumothoraxcasereport AT rohwedderthomas partiallunglobectomywiththecaimansealcutdeviceinadogwithspontaneouspneumothoraxcasereport AT bottcherpeter partiallunglobectomywiththecaimansealcutdeviceinadogwithspontaneouspneumothoraxcasereport |