Cargando…

Elimination of lipaemic interference by high-speed centrifugation

INTRODUCTION: In order to deliver high quality results, detection and elimination of possible analytical interferences, such as lipaemia, is crucial. The aim of this study is to evaluate the efficacy of high-speed centrifugation in eliminating lipaemic interference and to define own lipaemic index (...

Descripción completa

Detalles Bibliográficos
Autores principales: Solé-Enrech, Gemma, Cano-Corres, Ruth, Aparicio-Calvente, Maria Isabel, Spataro, Nino
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Croatian Society of Medical Biochemistry and Laboratory Medicine 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9807237/
https://www.ncbi.nlm.nih.gov/pubmed/36627977
http://dx.doi.org/10.11613/BM.2023.010703
Descripción
Sumario:INTRODUCTION: In order to deliver high quality results, detection and elimination of possible analytical interferences, such as lipaemia, is crucial. The aim of this study is to evaluate the efficacy of high-speed centrifugation in eliminating lipaemic interference and to define own lipaemic index (LI) for the studied biochemical analytes. MATERIALS AND METHODS: Evaluated analytes were: albumin, alkaline phosphatase, alanine-aminotransferase (ALT), aspartate-aminotransferase (AST), calcium, creatinine, gamma-glutamyltransferase (GGT), glucose, phosphates, total proteins, urea and total bilirubin. Those analytes and LIs have been analysed in duplicate in the Roche Diagnostics-c8000 analyser in samples centrifuged at 3000 rpm/10 minutes in the SL16 (Thermo Scientific, Waltham, USA) centrifuge and according to an own high-speed centrifugation protocol (12,900 rpm/15 minutes) in the MicroCL17R (Thermo Scientific, Waltham, USA) centrifuge. Lipaemia has been measured in each sample. The efficiency of high-speed centrifugation is verified by the Wilcoxon test (P < 0.05). In cases where significant differences are observed, our own LI is calculated. For ALT and AST, it is verified by McNemar test (P < 0.05). For creatinine, both Wilcoxon and McNemar test were applied. RESULTS: There were statistically significant differences in analyte concentration before and after high-speed centrifugation for: albumin, creatinine, GGT, glucose, phosphates, urea and total bilirrubin. Own LI is calculated. McNemar test shows statistically significant diferences in the proportion of delivered results before and after high-speed centrifugation in ALT, AST and creatinine. CONCLUSIONS: This study confirms the efficacy of high-speed centrifugation protocol for all the considered analytes, excepting calcium, alkaline phosphatase and total proteins.