Cargando…
Elimination of lipaemic interference by high-speed centrifugation
INTRODUCTION: In order to deliver high quality results, detection and elimination of possible analytical interferences, such as lipaemia, is crucial. The aim of this study is to evaluate the efficacy of high-speed centrifugation in eliminating lipaemic interference and to define own lipaemic index (...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Croatian Society of Medical Biochemistry and Laboratory Medicine
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9807237/ https://www.ncbi.nlm.nih.gov/pubmed/36627977 http://dx.doi.org/10.11613/BM.2023.010703 |
_version_ | 1784862679177887744 |
---|---|
author | Solé-Enrech, Gemma Cano-Corres, Ruth Aparicio-Calvente, Maria Isabel Spataro, Nino |
author_facet | Solé-Enrech, Gemma Cano-Corres, Ruth Aparicio-Calvente, Maria Isabel Spataro, Nino |
author_sort | Solé-Enrech, Gemma |
collection | PubMed |
description | INTRODUCTION: In order to deliver high quality results, detection and elimination of possible analytical interferences, such as lipaemia, is crucial. The aim of this study is to evaluate the efficacy of high-speed centrifugation in eliminating lipaemic interference and to define own lipaemic index (LI) for the studied biochemical analytes. MATERIALS AND METHODS: Evaluated analytes were: albumin, alkaline phosphatase, alanine-aminotransferase (ALT), aspartate-aminotransferase (AST), calcium, creatinine, gamma-glutamyltransferase (GGT), glucose, phosphates, total proteins, urea and total bilirubin. Those analytes and LIs have been analysed in duplicate in the Roche Diagnostics-c8000 analyser in samples centrifuged at 3000 rpm/10 minutes in the SL16 (Thermo Scientific, Waltham, USA) centrifuge and according to an own high-speed centrifugation protocol (12,900 rpm/15 minutes) in the MicroCL17R (Thermo Scientific, Waltham, USA) centrifuge. Lipaemia has been measured in each sample. The efficiency of high-speed centrifugation is verified by the Wilcoxon test (P < 0.05). In cases where significant differences are observed, our own LI is calculated. For ALT and AST, it is verified by McNemar test (P < 0.05). For creatinine, both Wilcoxon and McNemar test were applied. RESULTS: There were statistically significant differences in analyte concentration before and after high-speed centrifugation for: albumin, creatinine, GGT, glucose, phosphates, urea and total bilirrubin. Own LI is calculated. McNemar test shows statistically significant diferences in the proportion of delivered results before and after high-speed centrifugation in ALT, AST and creatinine. CONCLUSIONS: This study confirms the efficacy of high-speed centrifugation protocol for all the considered analytes, excepting calcium, alkaline phosphatase and total proteins. |
format | Online Article Text |
id | pubmed-9807237 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Croatian Society of Medical Biochemistry and Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-98072372023-01-09 Elimination of lipaemic interference by high-speed centrifugation Solé-Enrech, Gemma Cano-Corres, Ruth Aparicio-Calvente, Maria Isabel Spataro, Nino Biochem Med (Zagreb) Original Articles INTRODUCTION: In order to deliver high quality results, detection and elimination of possible analytical interferences, such as lipaemia, is crucial. The aim of this study is to evaluate the efficacy of high-speed centrifugation in eliminating lipaemic interference and to define own lipaemic index (LI) for the studied biochemical analytes. MATERIALS AND METHODS: Evaluated analytes were: albumin, alkaline phosphatase, alanine-aminotransferase (ALT), aspartate-aminotransferase (AST), calcium, creatinine, gamma-glutamyltransferase (GGT), glucose, phosphates, total proteins, urea and total bilirubin. Those analytes and LIs have been analysed in duplicate in the Roche Diagnostics-c8000 analyser in samples centrifuged at 3000 rpm/10 minutes in the SL16 (Thermo Scientific, Waltham, USA) centrifuge and according to an own high-speed centrifugation protocol (12,900 rpm/15 minutes) in the MicroCL17R (Thermo Scientific, Waltham, USA) centrifuge. Lipaemia has been measured in each sample. The efficiency of high-speed centrifugation is verified by the Wilcoxon test (P < 0.05). In cases where significant differences are observed, our own LI is calculated. For ALT and AST, it is verified by McNemar test (P < 0.05). For creatinine, both Wilcoxon and McNemar test were applied. RESULTS: There were statistically significant differences in analyte concentration before and after high-speed centrifugation for: albumin, creatinine, GGT, glucose, phosphates, urea and total bilirrubin. Own LI is calculated. McNemar test shows statistically significant diferences in the proportion of delivered results before and after high-speed centrifugation in ALT, AST and creatinine. CONCLUSIONS: This study confirms the efficacy of high-speed centrifugation protocol for all the considered analytes, excepting calcium, alkaline phosphatase and total proteins. Croatian Society of Medical Biochemistry and Laboratory Medicine 2022-12-15 2023-02-15 /pmc/articles/PMC9807237/ /pubmed/36627977 http://dx.doi.org/10.11613/BM.2023.010703 Text en Croatian Society of Medical Biochemistry and Laboratory Medicine. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Articles Solé-Enrech, Gemma Cano-Corres, Ruth Aparicio-Calvente, Maria Isabel Spataro, Nino Elimination of lipaemic interference by high-speed centrifugation |
title | Elimination of lipaemic interference by high-speed centrifugation |
title_full | Elimination of lipaemic interference by high-speed centrifugation |
title_fullStr | Elimination of lipaemic interference by high-speed centrifugation |
title_full_unstemmed | Elimination of lipaemic interference by high-speed centrifugation |
title_short | Elimination of lipaemic interference by high-speed centrifugation |
title_sort | elimination of lipaemic interference by high-speed centrifugation |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9807237/ https://www.ncbi.nlm.nih.gov/pubmed/36627977 http://dx.doi.org/10.11613/BM.2023.010703 |
work_keys_str_mv | AT soleenrechgemma eliminationoflipaemicinterferencebyhighspeedcentrifugation AT canocorresruth eliminationoflipaemicinterferencebyhighspeedcentrifugation AT apariciocalventemariaisabel eliminationoflipaemicinterferencebyhighspeedcentrifugation AT spataronino eliminationoflipaemicinterferencebyhighspeedcentrifugation |