Cargando…
Wearables for Running Gait Analysis: A Systematic Review
BACKGROUND: Running gait assessment has traditionally been performed using subjective observation or expensive laboratory-based objective technologies, such as three-dimensional motion capture or force plates. However, recent developments in wearable devices allow for continuous monitoring and analy...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9807497/ https://www.ncbi.nlm.nih.gov/pubmed/36242762 http://dx.doi.org/10.1007/s40279-022-01760-6 |
_version_ | 1784862732293505024 |
---|---|
author | Mason, Rachel Pearson, Liam T. Barry, Gillian Young, Fraser Lennon, Oisin Godfrey, Alan Stuart, Samuel |
author_facet | Mason, Rachel Pearson, Liam T. Barry, Gillian Young, Fraser Lennon, Oisin Godfrey, Alan Stuart, Samuel |
author_sort | Mason, Rachel |
collection | PubMed |
description | BACKGROUND: Running gait assessment has traditionally been performed using subjective observation or expensive laboratory-based objective technologies, such as three-dimensional motion capture or force plates. However, recent developments in wearable devices allow for continuous monitoring and analysis of running mechanics in any environment. Objective measurement of running gait is an important (clinical) tool for injury assessment and provides measures that can be used to enhance performance. OBJECTIVES: We aimed to systematically review the available literature investigating how wearable technology is being used for running gait analysis in adults. METHODS: A systematic search of the literature was conducted in the following scientific databases: PubMed, Scopus, Web of Science and SPORTDiscus. Information was extracted from each included article regarding the type of study, participants, protocol, wearable device(s), main outcomes/measures, analysis and key findings. RESULTS: A total of 131 articles were reviewed: 56 investigated the validity of wearable technology, 22 examined the reliability and 77 focused on applied use. Most studies used inertial measurement units (n = 62) [i.e. a combination of accelerometers, gyroscopes and magnetometers in a single unit] or solely accelerometers (n = 40), with one using gyroscopes alone and 31 using pressure sensors. On average, studies used one wearable device to examine running gait. Wearable locations were distributed among the shank, shoe and waist. The mean number of participants was 26 (± 27), with an average age of 28.3 (± 7.0) years. Most studies took place indoors (n = 93), using a treadmill (n = 62), with the main aims seeking to identify running gait outcomes or investigate the effects of injury, fatigue, intrinsic factors (e.g. age, sex, morphology) or footwear on running gait outcomes. Generally, wearables were found to be valid and reliable tools for assessing running gait compared to reference standards. CONCLUSIONS: This comprehensive review highlighted that most studies that have examined running gait using wearable sensors have done so with young adult recreational runners, using one inertial measurement unit sensor, with participants running on a treadmill and reporting outcomes of ground contact time, stride length, stride frequency and tibial acceleration. Future studies are required to obtain consensus regarding terminology, protocols for testing validity and the reliability of devices and suitability of gait outcomes. CLINICAL TRIAL REGISTRATION: CRD42021235527. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s40279-022-01760-6. |
format | Online Article Text |
id | pubmed-9807497 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-98074972023-01-04 Wearables for Running Gait Analysis: A Systematic Review Mason, Rachel Pearson, Liam T. Barry, Gillian Young, Fraser Lennon, Oisin Godfrey, Alan Stuart, Samuel Sports Med Systematic Review BACKGROUND: Running gait assessment has traditionally been performed using subjective observation or expensive laboratory-based objective technologies, such as three-dimensional motion capture or force plates. However, recent developments in wearable devices allow for continuous monitoring and analysis of running mechanics in any environment. Objective measurement of running gait is an important (clinical) tool for injury assessment and provides measures that can be used to enhance performance. OBJECTIVES: We aimed to systematically review the available literature investigating how wearable technology is being used for running gait analysis in adults. METHODS: A systematic search of the literature was conducted in the following scientific databases: PubMed, Scopus, Web of Science and SPORTDiscus. Information was extracted from each included article regarding the type of study, participants, protocol, wearable device(s), main outcomes/measures, analysis and key findings. RESULTS: A total of 131 articles were reviewed: 56 investigated the validity of wearable technology, 22 examined the reliability and 77 focused on applied use. Most studies used inertial measurement units (n = 62) [i.e. a combination of accelerometers, gyroscopes and magnetometers in a single unit] or solely accelerometers (n = 40), with one using gyroscopes alone and 31 using pressure sensors. On average, studies used one wearable device to examine running gait. Wearable locations were distributed among the shank, shoe and waist. The mean number of participants was 26 (± 27), with an average age of 28.3 (± 7.0) years. Most studies took place indoors (n = 93), using a treadmill (n = 62), with the main aims seeking to identify running gait outcomes or investigate the effects of injury, fatigue, intrinsic factors (e.g. age, sex, morphology) or footwear on running gait outcomes. Generally, wearables were found to be valid and reliable tools for assessing running gait compared to reference standards. CONCLUSIONS: This comprehensive review highlighted that most studies that have examined running gait using wearable sensors have done so with young adult recreational runners, using one inertial measurement unit sensor, with participants running on a treadmill and reporting outcomes of ground contact time, stride length, stride frequency and tibial acceleration. Future studies are required to obtain consensus regarding terminology, protocols for testing validity and the reliability of devices and suitability of gait outcomes. CLINICAL TRIAL REGISTRATION: CRD42021235527. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s40279-022-01760-6. Springer International Publishing 2022-10-15 2023 /pmc/articles/PMC9807497/ /pubmed/36242762 http://dx.doi.org/10.1007/s40279-022-01760-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Systematic Review Mason, Rachel Pearson, Liam T. Barry, Gillian Young, Fraser Lennon, Oisin Godfrey, Alan Stuart, Samuel Wearables for Running Gait Analysis: A Systematic Review |
title | Wearables for Running Gait Analysis: A Systematic Review |
title_full | Wearables for Running Gait Analysis: A Systematic Review |
title_fullStr | Wearables for Running Gait Analysis: A Systematic Review |
title_full_unstemmed | Wearables for Running Gait Analysis: A Systematic Review |
title_short | Wearables for Running Gait Analysis: A Systematic Review |
title_sort | wearables for running gait analysis: a systematic review |
topic | Systematic Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9807497/ https://www.ncbi.nlm.nih.gov/pubmed/36242762 http://dx.doi.org/10.1007/s40279-022-01760-6 |
work_keys_str_mv | AT masonrachel wearablesforrunninggaitanalysisasystematicreview AT pearsonliamt wearablesforrunninggaitanalysisasystematicreview AT barrygillian wearablesforrunninggaitanalysisasystematicreview AT youngfraser wearablesforrunninggaitanalysisasystematicreview AT lennonoisin wearablesforrunninggaitanalysisasystematicreview AT godfreyalan wearablesforrunninggaitanalysisasystematicreview AT stuartsamuel wearablesforrunninggaitanalysisasystematicreview |