Cargando…

Assessment of cardiotoxicity and plasma ropivacaine concentrations after serratus intercostal fascial plane block in an experimental model

Serratus intercostal fascial plane block (SIFPB) has emerged as an alternative to paravertebral block in breast surgery. It involves the administration of high volumes and doses of local anesthetics (LA) that can potentially reach toxic levels. Ropivacaine is widely used in thoraco-fascial blocks; h...

Descripción completa

Detalles Bibliográficos
Autores principales: Zaballos, Matilde, Varela, Olalla, Fernández, Ignacio, Rodríguez, Lucía, García, Sergio, Quintela, Oscar, Vázquez, Elena, Anadón, María-José, Almendral, Jesús
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9807569/
https://www.ncbi.nlm.nih.gov/pubmed/36593251
http://dx.doi.org/10.1038/s41598-022-26557-5
Descripción
Sumario:Serratus intercostal fascial plane block (SIFPB) has emerged as an alternative to paravertebral block in breast surgery. It involves the administration of high volumes and doses of local anesthetics (LA) that can potentially reach toxic levels. Ropivacaine is widely used in thoraco-fascial blocks; however, there is no information on the plasma concentrations attained after SIPFB and whether they are associated with cardiotoxicity. Plasma concentrations of ropivacaine and its electrophysiological effects were evaluated in eight pigs after bilateral SIFPB with ropivacaine in doses of 3 mg/kg. Plasma concentrations, electrophysiological and hemodynamic parameters were measured sequentially for the following 180 min until the end of the study. The area under the curve, the maximum plasma concentration (C(max)) and the time to reach C(max) (t(max)) were calculated. The median arterial ropivacaine concentration C(max) was, 2.34 [1.40 to 3.74] µg/ml. The time to reach the highest concentration was 15 [10 to 20] min. Twenty-five percent of the animals had arterial concentrations above the lower limit concentration of ropivacaine for LA systemic toxicity (3.4 µg/ml). No alterations were observed in the electrophysiological or electrocardiographic parameters except for a prolongation of the QTc interval, from 489 ± 30 to 544 ± 44 ms (Δ11.38 ± 6%), P = 0.01. Hemodynamic parameters remained in the physiological range throughout the study. SIFPB with ropivacaine in doses of 3 mg/kg has reached potentially toxic levels, however, it has not been associated with adverse electrophysiological or hemodynamic effects.